This is a
1. Set your Z-Wave controller into pairing mode.
2. Press the Action Button on the Nano Switch or toggle the external manual switch once, the green LED (non-secure indication) will blink to indicate the Nano Switch is entering into pairing mode.
Notes for the wire connection ports:
Reset to factory default | Set Parameter 255 |
Inclusion | 1. Set your Z-Wave controller into pairing mode. 2. Press the Action Button on the Nano Switch or toggle the external manual switch once, the green LED (non-secure indication) will blink to indicate the Nano Switch is entering into pairing mode. |
Exclusion | 1. Set your Z-Wave controller into removal mode.
2. Press the Action Button on the Nano Switch or toggle the external manual switch 3 times in fast succession.
|
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline.When the load state of Nano Switch (on/off) is changed, the Hail CC, Switch Multilevel Report and Basic Report (configured by parameter 80) can be sent to the associated nodes in this group. |
2 | 5 | Forward the Basic Set, Switch All, Scene Activation Set to associated nodes in Group 2 when the Nano Switch receives the Basic Set, Switch All, Scene Activation Set commands from main controller. |
3 | 5 | Send Basic Set (configured by parameter 82) to the associated nodes in Group 3 when the external switch S1 is operated |
4 | 5 | Send Basic Set (configured by parameter 82) to the associated nodes in Group 4 when the external switch S2 is operated |
Over current protection. Output load will be closed after 30 seconds if the current exceeds (US: 15.5A, AU or EU: 10.5A) Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Output Load will be turned off automatically after 30 seconds and if the temperature of product inside exceeds 100°C. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Configure the output status after re-power on it. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Last status |
1 | Always on |
2 | Always off |
To set which notification would be sent to the associated devices (Group 1) when the state of Nano Dimmers load is changed. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Send Nothing |
1 | Send Hail CC |
2 | Send Basic CC report |
3 | Send Multilevel Switch report |
4 | Send Hail CC when using the manual switch to change the load state. |
To set which notification would be sent to the associated nodes in association Group 3 when using the external switch 1 to switch the loads. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Send Nothing |
1 | Send Basic Set CC |
To set which notification would be sent to the associated nodes in association Group 4 when using the external switch 2 to switch the loads. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Send Nothing |
1 | Send Basic Set CC |
Configure the state of LED when it is in 3 modes Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | The LED will follow the status (on/off) of its load (Energy mode). |
256 - 316 | The hour value of ON time |
2 | Night light mode. |
Set the ON/OFF time of the LED when it is in Night light mode. Size: 4 Byte, Default Value: 524306
Setting | Description |
---|---|
0 - 60 | The minute time of OFF |
256 - 316 | The hour time of OFF |
65536 - 65596 | The minute time of ON |
16777216 - 16777276 | The hour time of ON |
Set appointment 1 Size: 4 Byte, Default Value: 2293760
Setting | Description |
---|---|
0 - 60 | The minute value of ON time |
256 - 316 | The minute value of ON time |
65536 - 65543 | The day value (Mon to Sun) |
16777215 | Disable the setting. |
16777216 | Enable the setting. |
Set appointment 2 Size: 4 Byte, Default Value: 2293760
Setting | Description |
---|---|
0 - 60 | The minute value of ON time |
256 - 316 | The hour value of ON time |
65536 - 65543 | The day value (Mon to Sun) |
16777215 | Disable the setting. |
16777216 | Enable the setting. |
Enables/disables the function of parameter 91 and 92. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Threshold change in wattage (in terms of wattage) to induce an automatic report. Size: 2 Byte, Default Value: 25
Setting | Description |
---|---|
0 - 60000 | The thershold value range is 0 to 60000 |
Threshold change in wattage (in terms of percentage) to induce an automatic report. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 - 100 | The thershold value range is 0 to 100 |
Set parameter 101-103 to default value. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Reset the parameter 101-103 |
To set which reports need to be sent in Report group 1. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Send Meter Report of voltage (V) |
2 | Send Meter Report of current (A) |
4 | Send Meter Report of wattage (W) |
8 | Send Meter Report of energy (kWh) |
To set which reports need to be sent in Report group 2. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Send Meter Report of voltage (V) |
2 | Send Meter Report of current (A) |
4 | Send Meter Report of wattage (W) |
8 | Send Meter Report of energy (kWh) |
To set which reports need to be sent in Report group 3. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Send Meter Report of voltage (V) |
2 | Send Meter Report of current (A) |
4 | Send Meter Report of wattage (W) |
8 | Send Meter Report of energy (kWh) |
Set parameter 111-113 to default value. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Reset the parameter 111-113 |
Set the interval of automatic report for Report group 1. Size: 4 Byte, Default Value: 3
Setting | Description |
---|---|
1 - 2147483647 | The range of interval time is 1 to 2147483647. |
Set the interval of automatic report for Report group 2. Size: 4 Byte, Default Value: 600
Setting | Description |
---|---|
1 - 2147483647 | The range of interval time is 1 to 2147483647. |
Set the interval of automatic report for Report group 3. Size: 4 Byte, Default Value: 600
Setting | Description |
---|---|
1 - 2147483647 | The range of interval time is 1 to 2147483647. |
Configure the external switch mode for S1. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Enter automatic identification mode |
1 | Momentary push button mode |
2 | 3 way switch mode |
3 | 2-state switch mode |
Configure the external switch mode for S2. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Enter automatic identification mode |
1 | Momentary push button mode |
2 | 3 way switch mode |
3 | 2-state switch mode |
Set the control destination of the external switch. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 | control the output loads of itself. |
2 | control the other nodes |
3 | control the output loads of itself and other nodes. |
Lock/unlock configuration parameters. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Unlock |
1 | Lock |
Reset the Nano Dimmer to factory default. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Reset all configuration parameters to factory default setting |
1431655765 | Reset to factory default setting and removed from the z-wave network |
Dimensions | 0.0437000x0.0198000x0.0400000 mm |
Weight | 33 gr |
Hardware Platform | ZM5202 |
EAN | 4251295701110 |
IP Class | IP 20 |
Voltage | 24V DC/ 230V AC |
Load | 6,5 A |
Device Type | On/Off Power Switch |
Generic Device Class | Binary Switch |
Specific Device Class | Binary Power Switch |
Firmware Version | 01.00 |
Z-Wave Version | 04.22 |
Certification ID | ZC10-17035496 |
Z-Wave Product Id | 0x0086.0x0003.0x0074 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |