Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please insert fresh 1 * CR123A batteries. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:

  1. Have Z-Wave Controller entered inclusion mode. 
  2. Pressing tamper key three times within 1.5 seconds to enter the inclusion mode. 
  3. After add successful, the device will wake to receive the setting command from Z-Wave Controller about 20 seconds.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The 4 in 1 Door/Window Sensor is a real all-rounder: It registers every movement, measures temperatures, detects different brightness levels and can also be used as a door/window sensor. It immediately reports all measured data to the Smart Home control center and thus enables various scenarios to be initiated.

The sensor consists of 2 parts: a main part with sensor and a magnet. The magnet is attached to the moving part and the detector to the frame of the door or window. When the door or window opens, the magnetic field moves, causing the detector to strike and generate an alarm condition while the system is armed.

The light sensor can also be used for light control by determining the light level, which can be passed to a Z-Wave switch. The switch will always turn on the light when the door is opened and the room behind it is dark. Each time the 4 in 1 Door/Window Sensor triggers, the sensor also sends temperature and brightness values - for example, they can be paired with a radiator thermostat and downshoot the heating if a window is opened.

With the 4-in-1 Door/Window Sensor, you get an all-rounder Smart Home element, a small device which comes with a total of four different sensors:

  • Door / Window Sensor
  • Temperature Sensor
  • Brightness sensor
  • Motion detector

Features

  •  Z-Wave Plus certified 4 in 1 Door?/Window Sensor
  • Magnetic door?/?window sensor
  • Temperature sensor in °C
  • Brightness sensor in %
  • PIR motion sensor
  • Tamper protection 

Specifications

  • Up to 2 years battery lifetime
  • 1x CR?123 lithium battery (included)
  • Dimensions: 28×23×96mm

Installation

Battery Installation

When the device report the low battery message. The user should replace the battery to new one. The battery type is CR123A, 3.0V. The way to open the front cover please follow below steps. 
  • Using a tool to press the 1-1 position, to release the cover.
  • Hold the front cover and pull back
  • Hold the front cover and pull up


Replace the new battery and install the cover back.
  • Put the front cover bottom to 1-1, and press down.
  • Push the front cover top to 2-1.


Choosing a Suitable Location
  • The recommended mounting height is 160cm
  • Don"t let the device facing the window or the sunlight.
  • Don"t let the device facing the source of heat. For instance the heater or the air-condition.

Installation
  • In the first time, add the device into the Z-WaveTM network. First, make sure the primary controller is in the inclusion mode. And then power on the device, just take out the insulation Mylar in the back side of the device. The device will auto start the NWI (Network Wide Inclusion) mode. And it should be included in 5 seconds. You will see the LED light ON one second. 
  • Let the controller associate with the device into the first group, any light switch that intend to be turned on when the device trig please associate with the device into the second group. 
  • In the accessory pack. There are two type of double coated tape, one is thicker (hereinafter referred to as A tape) and another is thinner (hereinafter referred to as B tape), you can use A tape for the test at the beginning. The right way for A tape installation is stick it to the position below tamper key. The thicker tape won"t let the tamper key pressed, so the sensor will enter the test mode, You may test if installed position is good or not by this way.



After finish the test and decide to fix, then you can remove tape A, and mounting the sensor by using tape B. The tamper key will pressed and let the sensor enter normal mode. 

Reset to factory default
  1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4th pressed, and the LED will light ON.
  2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once. 
  3. IDs are excluded and all settings will reset to factory default.
Inclusion
  1. Have Z-Wave Controller entered inclusion mode. 
  2. Pressing tamper key three times within 1.5 seconds to enter the inclusion mode. 
  3. After add successful, the device will wake to receive the setting command from Z-Wave Controller about 20 seconds.
Exclusion
  1. Have Z-Wave Controller entered exclusion mode. 
  2. Pressing tamper key three times within 1.5 seconds to enter the exclusion mode. 
  3. Node ID has been excluded.
NIF Press any key once, the device will awake 10 seconds.
Wakeup Press any key once, the device will awake 10 seconds.
Protection XXXProtection
FirmwareUpdate The device support the Z-Wave firmware update via OTA. Before starting the procedure, please remove the front cover of the device. Otherwise the hardware check will be failed. Let the controller into the firmware update mode, and then press the front tamper key once to start the update.  After finish the firmware download, the LED will start flash in every 0.5 second. At that time, please don"t remove the battery, otherwise it will cause the firmware broken, and the device will no function. After the LED stop flash, it is recommended that the user power up the device. Caution: After remove the battery, please wait about 30
seconds, and then re-install the battery.
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 8
Receiving the report message, like triggered event, temperature, illumination etc.
2 8
Light control, the device will send the “Basic Set” command

Configuration Parameters

Parameter 2: Basic Set Level

Setting the BASIC command value to turn on the light
Size: 1 Byte, Default Value: 255

Setting Description
0 turn off the light
1 - 100 the light strength.
254 turn on the light.

Parameter 3: PIR Sensitivity

PIR sensitivity settings.
Size: 1 Byte, Default Value: 80

Setting Description
0 disable the PIR motion.
1 - 99 1 means the lowest sensitivity, 99 means the highest sensitivity. High sensitivity means can detected long distance, but if there is more noise signal in the environment, it will re-trigger too frequency.

Parameter 4: Light Threshold

Setting the illumination threshold to turn on the light. When the event triggered and the environment illumination lower then the threshold, the device will turn on the light. 0 means turn off illumination detected function. And never turn on the light.
Notice: In none test mode, only the value in 1 to 99 will enable the illumination detected function and update the illumination value.

Size: 1 Byte, Default Value: 99

Setting Description
0 turn off illumination detected function.
1 - 100 1 means darkest. 99 means brightest. 100 means turn off illumination detected function. And always turn on the light.

Parameter 5: Operation Mode

Operation mode. Using bit to control.
Size: 1 Byte, Default Value: 0

Setting Description
1 Reserve.
2 1 means test mode, 0 means normal mode. Notice: This bit only effect by the DIP Switch setting to “customer mode”, otherwise it decides by DIP Switch setting to Test or Normal Mode
4 Disable the door/window function. (1:Disable, 0:Enable)
8 Setting the temperature scale. 0: Fahrenheit, 1:Celsius
16 Disable the illumination report after event triggered. (1:Disable, 0:Enable)
32 Disable the temperature report after event triggered. (1:Disable, 0:Enable)
64 Reserve.
128 Disable the back key release into test mode. (1:Disable, 0:Enable)

Parameter 6: Mult-Sensor Function Switch

Multisensor function switch. Using bit to control.
Size: 1 Byte, Default Value: 4

Setting Description
1 Disable magnetic integrate illumination to turn ON the lighting nodes in the association group 2. (1:Disable, 0:Enable)
2 Disable PIR integrate Illumination to turn ON the lighting nodes in the association group 2. (1:Disable, 0:Enable)
4 Disable magnetic integrate PIR to turn ON the lighting nodes in the association group 2. (1:Disable, 0:Enable) (Default is Disable)
8 When Bit2 is 0 (Enable), are the device and the lighting in the same room? 0: In the same room(Default), 1: In the different room. Notice: If this bit is 1, it is recommended also set the Bit1 to 1, cause the PIR triggered, doesnt mean the people in that room.
16 Disable delay 5 seconds to turn off the light, when door/window closed. (1:Disable, 0:Enable)
32 Disable auto turn off the light, after door/window opened to turn on the light. (1:Disable, 0:Enable)
64 Reserve.
128 Reserve.

Parameter 7: Customer Function

Customer function switch, using bit control.
Size: 1 Byte, Default Value: 4

Setting Description
1 Reserve.
2 Enable sending motion OFF report. (0:Disable, 1:Enable)
4 Enable PIR super sensitivity mode. (0:Disable, 1:Enable)
8 Disable send out BASIC OFF after door closed. (1:Disable, 0:Enable)
16 Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report.
32 Disable Multi CC in auto report. (1:Disable, 0:Enable)
64 Disable to report battery state when the device triggered. (1:Disable, 0:Enable)
128 Reserve.

Parameter 8: PIR Re-Detect Interval Time

In the normal mode, after the PIR motion detected, setting the re-detect time. 8 seconds per tick, default tick is 3 (24 seconds).Setting the suitable value to prevent received the trigger signal too frequently. Also can save the battery energy.Notice: If this value bigger than the configuration setting NO. 9. There is a period after the light turned off and the PIR not start detecting.
Size: 1 Byte, Default Value: 3

Setting Description
1 - 127 PIR Re-Detect Interval Time

Parameter 9: Turn Off Light Time

After turn on the lighting, setting the delay time to turn off the lighting when the PIR motion is not detected. 8 seconds per tick, default tick is 4 (32 seconds).0 means never send turn off light command.
Size: 1 Byte, Default Value: 4

Setting Description
0 - 127 Turn Off Light Time

Parameter 10: Auto Report Battery Time

The interval time for auto report the battery level. 0 means turn off auto report battery.The default value is 12. The tick time can setting by the configuration No.20.
Size: 1 Byte, Default Value: 12

Setting Description
0 - 127 Auto Report Battery Time

Parameter 11: Auto Report Door/Window State Time

The interval time for auto report the door/window state. 0 means turn off auto report door/window state. The default value is 12. The tick time can setting by the configuration No.20.
Size: 1 Byte, Default Value: 12

Setting Description
0 - 127 Auto Report Door/Window State Time

Parameter 12: Auto Report Illumination Time

The interval time for auto report the illumination. 0 means turn off auto report illumination.The default value is 12. The tick time can setting by the configuration No.20.
Size: 1 Byte, Default Value: 12

Setting Description
0 - 127 Auto Report Illumination Time

Parameter 13: Auto Report Temperature Time

The interval time for auto report the temperature. 0 means turn off auto report temperature.The default value is 12. The tick time can setting by the configuration No.20.
Size: 1 Byte, Default Value: 12

Setting Description
0 - 127 Auto Report Temperature Time

Parameter 20: Auto Report Tick Interval

The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.11, No.12 and No.13.Caution: Setting to 0 means turn off all auto report function.
Size: 1 Byte, Default Value: 30

Setting Description
0 - 255 Auto Report Tick Interval

Parameter 21: Temperature Differential Report

The temperature differential to report.0 means turn off this function. The unit is Fahrenheit.Enable this function the device will detect every minutes. And when the temperature is over 140 degree Fahrenheit, it will continue report.Enable this functionality will cause some issue please see the detail in the u201cTemperature Reportu201d section.
Size: 1 Byte, Default Value: 1

Setting Description
0 - 127 Temperature Differential Report

Parameter 22: Illumination Differential Report

The illumination differential to report.0 means turn off this function. The unit is percentage.Enable this function the device will detect every minutes. Enable this functionality will cause some issue please see the detail in the Illumination Report section.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 99 Illumination Differential Report

Technical Data

Dimensions 95x28x35 mm
Weight 48 gr
Hardware Platform ZM5202
EAN 4713698570163
IP Class IP 20
Battery Type 1 * CR123A
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Z-Wave Version 6.51.02
Certification ID ZC10-14080012
Z-Wave Product Id 0x013C.0x0002.0x000C
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeNotification Sensor