This is a
Single click the button located near the Status Indication LED or alternatively press quickly 6 times the external switch/button control to include or exclude the device. If the Aeon Labs Micro Smart Energy Switch is not included into any Z-Wave network, the LED will be blinking slowly continually.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
The Aeon Labs Micro Smart Energy Switch is a low-cost Z-Wave appliance switch specifically used to enable Z-Wave command and control (on/off) for existing in-wall switches. The wireless module is powered from the mains supply and is a three-wire design which requires a neutral connection. In the event of power failure, non-volatile memory retains all programmed information relating to the units operating status.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
The device is a 3 wire design which requires a neutral connection. The module is powered from the main supply.
The schematics below show how to wire the actuator. The power supply and the appliance are connected by the Load, Power Input and Neutral connectors. The 3.3 Volt and External Switch connectors are for external switching.
After the electrical installation the device has to be implemented in the Z-Wave Network.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
The switch is operated by an external switch/button or wireless. The click on the switch sets the switch on or off.
The Aeon Labs Micro Smart Energy Switch can report wattage energy usage or kWh energy usage to a Z-Wave gateway or controller when requested. If this function is supported by the gateway/controller, the energy consumption will be displayed in the user interface of the gateway/controller. Please consult the operation manual for these gateways/controllers for specific instructions.
The Node Information Frame (NIF) is the business card of a Z-Wave device. It contains information about the device type and the technical capabilities. The inclusion and exclusion of the device is confirmed by sending out a Node Information Frame. Beside this it may be needed for certain network operations to send out a Node Information Frame. To issue a NIF execute the following action:
A single click at the Inclusion/Exclusion switch sends a Node Information Frame.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Status Reports |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Defines the value type to be sent as Sensor Report. Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | Power |
01 | Voltage |
This is a double byte value. The LSB defines the total time the device need to blink. The value if set in seconds. The MSB defines the on/off interval of the blinking. The unit is 0.1 s. Size: 2 Byte, Default Value: 0000
Setting | Description |
---|
Defines the automated status notification of an associated device when status changes Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | Deactivated |
01 | Hail sent |
02 | BASIC Report Sent |
Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | Disabled |
01 | Enabled |
The value represents the minimum change in Wattage for a Report to be sent . Size: 2 Byte, Default Value: 0032
Setting | Description |
---|---|
00 - 3500 | Value in Watt |
The value represents the minimum change in Wattage Percent for a report to be sent Size: 1 Byte, Default Value: 0a
Setting | Description |
---|---|
00 - 100 | Percentage |
Defines the type of report sent for the Reporting Group 1. Size: 4 Byte, Default Value: 00000008
Setting | Description |
---|---|
Byte 1: 00000100 | MultiSensor Report |
Byte 1: 00001000 | Meter Report for Watt |
Byte 1: 00010000 | Meter Report for kWh |
Defines the type of report sent for the Reporting Group 2. Size: 4 Byte, Default Value: 00000000
Setting | Description |
---|---|
Byte 1: 00000100 | MultiSensor Report |
Byte 1: 00001000 | Meter Report for Watt |
Byte 1: 00010000 | Meter Report for kWh |
Defines the type of report sent for the Reporting Group 3. Size: 4 Byte, Default Value: 00000000
Setting | Description |
---|---|
Byte 1: 00000100 | MultiSensor Report |
Byte 1: 00001000 | Meter Report for Watt |
Byte 1: 00010000 | Meter Report for kWh |
Defines the time interval when the defined report of Reporting Group 1 is sent out. Size: 4 Byte, Default Value: 000002d0
Setting | Description |
---|---|
00 - ffff | Seconds |
Defines the time interval when the defined report of Reporting Group 2 is sent out. Size: 4 Byte, Default Value: 000002d0
Setting | Description |
---|---|
00 - ffff | Seconds |
Defines the time interval when the defined report of Reporting Group 3 is sent out. Size: 4 Byte, Default Value: 0000ffff
Setting | Description |
---|---|
00 - ffff | Seconds |
Dimensions | 0.0510000x0.0510000x0.0190000 mm |
Weight | 38 gr |
Hardware Platform | ZM3102 |
EAN | 1220000011014 |
Device Type | On/Off Power Switch |
Generic Device Class | Binary Switch |
Specific Device Class | Binary Power Switch |
Firmware Version | 01.29 |
Z-Wave Version | 02.4e |
Certification ID | ZC08-13030006 |
Z-Wave Product Id | 0086.0003.000c |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |