Quickstart

This is a secure On/Off Power Switch for Europe. To run this device please connect it to your mains power supply.

A This is a Z-Wave actuator.

Inclusion and Exclusion are confirmed by a single click on the button. If the Aeon Labs Inline Smart Energy Switch is not included into any Z-Wave network, the LED will be blinking continually.The device supports secure communication.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.

This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.

If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.

Product Description

The Aeon Labs Inline Smart Energy Switch is a Z-Wave light switch specifically used to enable Z- Wave commands and control (on/off) a device that is connected to a standard Schuko Wall Outlet.

It can also report immediate wattage consumption or kWh energy usage over a period of time. The wireless module is powered from the mains supplys. In the event of power failure, non-volatile memory retains all programmed information relating to the units operating status. This device support secure communication when included by a controller that also supports secure communication. The device will then send all commands as secure commands unless the receiving device can not accept them. Then the command is send the normal way automatically.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.

Installation

This device be plugged between every Standard-Schuko wall outlet and the electrical appliance with maximum load of 3500W. To switch the plugged device on or off simply push the local button once or use a Z-Wave Controller. The status is shown by the status LED at the device.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.

Inclusion

To include this device with your Z-Wave controller simple bring it in the inclusion mode and click the Inclusion/Exclusion button at the Aeon Labs Inline Smart Energy Switch once. If this device was successfully included to a Z-Wave network, the Status Indication LED will either be solid on or off (depending on if the switch is on or off) after the button was last pressed.

Exclusion

To include this device with your Z-Wave controller simple bring it in the inclusion mode and click the Inclusion/Exclusion button at the Aeon Labs Inline Smart Energy Switch once. If this device was successfully included to a Z-Wave network, the Status Indication LED will either be solid on or off (depending on if the switch is on or off) after the button was last pressed.

Product Usage

The switch is operated by the local switch/button or wireless via Z-Wave. The click on the switch sets the switch on or off.

The Aeon Labs Inline Smart Energy Switch can report wattage energy usage or kWh energy usage to a Z-Wave gateway or controller when requested. If this function is supported by the gateway/controller, the energy consumption will be displayed in the user interface of the gateway/controller. Please consult the operation manual for these gateways/controllers for specific instructions.

Node Information Frame

The Node Information Frame (NIF) is the business card of a Z-Wave device. It contains information about the device type and the technical capabilities. The inclusion and exclusion of the device is confirmed by sending out a Node Information Frame. Beside this it may be needed for certain network operations to send out a Node Information Frame. To issue a NIF execute the following action:

A single click at the Inclusion/Exclusion switch sends a Node Information Frame.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association - one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.

Association Groups:

Group Number Maximum Nodes Description
1 5 Group 1
2 5 Group 2
3 5 Group 3

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.

IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.

Parameter 2: Blinking Behavior

This is a double byte value. The LSB defines the total time the device needs to blink. The value if set in seconds. The MSB defines the on/off interval of the blinking. The unit is 0.1 s.
Size: 2 Byte, Default Value: 0000

Setting Description

Parameter 3: Current Overload Protection

Load will be closed when the Current overrun (US: 15.5A, other country: 16.2A) and the time more than 2 minutes (0=disabled, 1=enabled).
Size: 1 Byte, Default Value: 00

Setting Description
00 Active Overload Protection
01 Deactivate Overload Protection

Parameter 20: Output Load Status

Configure the output load status after reu2010power on.
Size: 1 Byte, Default Value: 00

Setting Description
00 last status
01 always on
02 always off

Parameter 80: Notification on Status Change

Defines the automated status notification of an associated device when status changes (0=nothing, 1=hail CC, 2=basic CC report).
Size: 1 Byte, Default Value: 00

Setting Description
00 nothing
01 hail
02 basic CC report

Parameter 81: Configure the state of red LED


Size: 1 Byte, Default Value: 00

Setting Description
00 The LED will follow the status (on/off) of its load.
01 When the state of Switchu2019s load changed, The LED will follow the status (on/off) of its load, but the red LED will turn off after 5 seconds if there is no any switch action.

Parameter 90: Enables/disables parameter 91/92


Size: 1 Byte, Default Value: 00

Setting Description
00 Enabled parameter 91/92
01 Disabled parameter 91/92

Parameter 91: Minimum Change to send Report (Watt)

The value represents the minimum change in wattage for a report to be sent .
Size: 2 Byte, Default Value: 0019

Setting Description

Parameter 92: Minimum Change to send Report (%)

The value represents the minimum change in wattage Percent for a report to be sent. (Valid values 0u2010100)
Size: 1 Byte, Default Value: 05

Setting Description

Parameter 100: Set 101u2010103 to default


Size: 1 Byte, Default Value: 00

Setting Description
00 set to default
01 nothing

Parameter 101: Report type send in Reporting Group 1

Defines the type of report sent for the Reporting Group 1.
Size: 4 Byte, Default Value: 00000008

Setting Description
00000002 Multisensor Report
00000004 Meter Report for Watt
00000008 Meter Report for kWh

Parameter 102: Report Type send in Reporting Group 2

Defines the type of report sent for the Reporting Group 2.
Size: 4 Byte, Default Value: 00000000

Setting Description
00000002 Multisensor-Report
00000004 Meter Report for Watt
00000008 Meter Report for kWh

Parameter 103: Report Type send in Reporting Group 3

Defines the type of report sent for the Reporting Group 3.
Size: 4 Byte, Default Value: 00000000

Setting Description
00000002 Multisensor-Report
00000004 Meter Report for Watt
00000008 Meter Report for kWh

Parameter 110: Set 111u2010113 to default


Size: 1 Byte, Default Value: 00

Setting Description
00 Set to default
01 nothing

Parameter 111: Send Interval for Reporting Group 1

Defines the time interval when the defined report of Reporting Group 1 is sent out.
Size: 4 Byte, Default Value: 000002d0

Setting Description

Parameter 112: Send Interval for Reporting Group 2

Defines the time interval when the defined report of Reporting Group 2 is sent out.
Size: 4 Byte, Default Value: 000002d0

Setting Description

Parameter 113: Send Interval for Reporting Group 3

Defines the time interval when the defined report of Reporting Group 3 is sent out.
Size: 4 Byte, Default Value: 0000ffff

Setting Description

Parameter 200: Partner ID


Size: 1 Byte, Default Value: 00

Setting Description
00 Aeon Labs Standard
01 AT&T

Parameter 252: Enable/disable Configuration Locked


Size: 1 Byte, Default Value: 00

Setting Description
00 Deactivate configurationlock
01 Activate configurationlock

Technical Data

Dimensions 0.0540000x0.0780000x0.0750000 mm
Weight 109 gr
EAN 1220000012578
Device Type On/Off Power Switch
Generic Device Class Binary Switch
Specific Device Class Binary Power Switch
Firmware Version 02.19
Z-Wave Version 03.53
Certification ID ZC10-14090009
Z-Wave Product Id 0086.0003.004b
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW

Supported Command Classes

  • Crc 16 Encap
  • Zwaveplus Info
  • Manufacturer Specific
  • Version
  • Security
  • Switch Binary
  • Switch All
  • Scene Activation
  • Scene Actuator Conf
  • Meter
  • Association Grp Info
  • Device Reset Locally
  • Configuration
  • Powerlevel
  • Firmware Update Md
  • Association
  • Hail

Controlled Command Classes

  • Device Reset Locally
  • Hail

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways,Remote Controls or battery operated wall controllers.
  • Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators and even remote controls.
  • Primary Controller — is the central organizer of the network. It must be a controller. There can be only one primary controller in a Z-Wave network.
  • Inclusion — is the process of adding new Z-Wave devices into a network.
  • Exclusion — is the process of removing Z-Wave devices from the network.
  • Association — is a control relationship between a controlling device and a controlled device.
  • Wakeup Notification — is a special wireless message issued by a Z-Wave device to announces that is able to communicate.
  • Node Information Frame — is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.