Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
The Energy Meter Reader measures electricity, gas and heat usage of analog and digital energy meters. Analog meters are read by means of optical sensors that can be placed on the energymeter to monitor the rotating disc or the blinking LED. In case of a digital meter, the meter adapter can be connected to the digital meter by means of a P1 digital communication interface. The meter adapter measures the cumulative and instantaneous gas and electricity consumption and sends this information to a Z-Wave enabled display (Quby Energy Display).
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
The Energy Meter Reader can be reset to factory default by pressing and holding the button for approximately 10 seconds. This will reset the entire device to factory default, also removing the Z-Wave set-tings. After the reset is complete, both LEDs will blink a single time (indicating startup). If the device was connected to a Z-Wave net-work, it will no longer be connected after reset.Please use this procedure only in the event that the primary controller is missing or otherwise inoperable.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In order to communicate with the device, a static controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time is significantly decreased.
This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbox. Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static controller this controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the device. To wakeup the device please perform the following action: N/A
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Z-Wave Plus Lifeline |
As long as this device is not included into a Z-Wave network of a different controller it is able to manage its own Z-Wave network as primary controller. As a primary controller the device can include and exclude other devices in its own network, manage associations, and reorganize the network in case of problems. The following controller functions are supported:
Communication between two Z-Wave devices only works if both belong to the same wireless network. Joining a network is called inclusion and is initiated by a controller. The controller needs to be turned into the inclusion mode. Once in this inclusion mode the other device needs to confirm the inclusion - typically by pressing a button.
If current primary controller in your network is in special SIS mode this and any other secondary controller can also include and exclude devices.
To become primary a contoller have to be resetted and then include a device.
To add the Energy Meter Reader into a Z-Wave network, the inclu-sion process should be started on the controller. In factory default mode, the Energy Meter Reader will try to join a Z-Wave network automatically after being plugged into a power socket. If the Energy Meter Reader was previously included in a Z-Wave network, or was not just plugged into a power socket, one needs to triple-press the button (quickly).
The primary controller can exclude devices from the Z-Wave network. During exclusion the relationship between the device and the network of this controller is terminated. No communication between the device and other devices still in the network can happen after a successful exclusion. The controller needs to be turned into the exclusion mode. Once in this exclusion mode the other device needs to confirm the exclusion - typically by pressing a button.
Attention: Removing a device from the network means that it is turned back into factory default status. This process can also exclude devices from it's previous network.
To remove the Energy Meter Reader from a Z-wave network, the exclusion process should be started on the controller. The button on the Energy Meter Reader should then be triple-pressed (quickly).
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
0 = Disabled1 = Gas enabled2 = Heat enabled
Size: 1 Byte, Default Value: 1
Setting | Description |
---|
pulses per cubic meter / pulses per MJ; in Q14.2 notation
Size: 4 Byte, Default Value: 400
Setting | Description |
---|
1 = Restart entire device2 = Restart metering chip
Size: 1 Byte, Default Value: 0
Setting | Description |
---|
0 = disabled1 = Electricity import enabled2 = Electricity export enabled
Size: 1 Byte, Default Value: 1
Setting | Description |
---|
pulses per kWh; in Q14.2 notation
Size: 4 Byte, Default Value: 400
Setting | Description |
---|
Hardware Platform | ZM5202 |
Device Type | Whole Home Meter - Simple |
Network Operation | Always On Slave |
Firmware Version | 01 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-15040005 |
Z-Wave Product Id | 0x0130.0x0002.0x0000 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |