When the device is not added to a Z-Wave network, then triple short clicks of the inclusion button will start the inclusion.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Z-Wave to Systemair HVAC Adapter is an Z-Wave Interface adapter, which connects the Z-Wave network with the Systemair Heat Recovery Ventilation. The Systemair HVAC is a residential HRV system, which can be controlled locally by one or more UI, as well as remotely by a mobile App or a browser via Z-Wave network.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
To do a Factory Reset the user must follow the following procedure: - Press and hold the inclusion button for 6 seconds, then - Release it, and then - Press it again and hold it for 3 secondsThe Z-Wave Adapter is indicating each phase with a different LED patternsee Operational modes and indicators in the User's Manual.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Read Only Parameter, shows what is the Type of the Systemair HVAC Unit. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 5 | See User Manual |
12 - 21 | See User Manual |
Read Only Parameter, shows how long the filter can be used in steps of 30 days. Example 6 = 180 days. Size: 2 Byte, Default Value: 12
Setting | Description |
---|---|
6 | x 30 = 180 days |
9 | x 30 = 270 days |
12 | x 30 = 360 days |
15 | x 30 = 450 days |
Read Only Parameter, shows how many days the filter has been used since the last change. The value can be used to calculate the Filter remaining time by the equation: Filter Remaining Days = (Parameter_2 x 30) - Parameter_3 Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 500 | The counter stops on 500 |
Read Only Parameter, shows how many seconds are left for Boost mode. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
240 - 0 | Counts down while Boost mode is active |
Read Only Parameter, shows the min change available in degrees Celsius x 10. Example 25 = 2.5 degree Celsius. Size: 2 Byte, Default Value: 10
Setting | Description |
---|---|
10 | /10 = 1.0 degrees Celsius step |
25 | /10 = 2.5 degrees Celsius setp |
Shows the Firmware Version available in the Z-Wave adapter for the Firmware Target 2. This parameter must be written after successful uploading of the firmware image for the local UI. Example UI Version 5.02.03:MSB - x, don't care,Next - 05,Next - 02,LSB - 03. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 16777215 | max version 255.255.255 |
Shows the Firmware Version available in the Z-Wave adapter for the Firmware Target 1. This parameter must be written after successful uploading of the firmware image for the Ventilation Unit. Example Ventilation Unit Version 6.07.08:MSB - x, don't care,Next - 06,Next - 07,LSB - 08. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 16777215 | max version 255.255.255 |
Hardware Platform | ZM5202 |
Device Type | Thermostat - HVAC |
Network Operation | Always On Slave |
Firmware Version | HW: 2 FW: 0.01:00.80:36.80:16.00 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-16065101 |
Z-Wave Product Id | 0x0276.0x0139.0x0001 |
Thermostat Modes | Auto ChangeoverAway |
Thermostat Power Source | Mains powered (120V/240V) |
Firmware Updatable | Updatable by Consumer by RF |
Thermostat HVAC Systems Supported | Humidity ControlVentilation Control |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |