Set the Z-Wave network main controller into learning mode. Short press the Z-button, the LED will keep turning on or off, which indicates the inclusion is successful.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Smart Plug is a Z-Wave Switch plugin module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool. It can report wattage consumption or kWh energy usage.Smart Plug is also a security Z-Wave device and supports the Over The Air (OTA) feature for the products firmware upgrade.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Press and hold the Z-button for more than 20 seconds, the LED will blink faster and faster when the button is pressed. If holding time more than 20seconds, the LED indicator will be on for 3 seconds then it blinking slowly, which indicates the reseting is successful. Use this procedure only in the event that the network primary controller is missing or otherwise inoperable.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Group 1 is assigned to the Lifeline association group and every device has 5 nodes to associate. When the switch is turned on or off , the switch will send a basic report of its status to the nodes in association group 1. To change what kind of signal is sent to the nodes in group 1, please see the detailed description of configuration parameter 24. |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
The value here represents minimum change in wattage (in terms of wattage) for sending a METER REPORT (for wattage) to the associated device (Group Lifeline). Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 | The function is disabled |
1 - 65535 | The minimum change value in wattage for sending a meter report to the associated device |
The value here represents minimum change in wattage percent (in terms of percentage) for sending a METER REPORT (for wattage) to the associated device (Group Lifeline). Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 | The function is disabled. |
1 - 255 | The minimum change value in wattage percent for sending a meter report to the associated device |
The time interval of sending Meter Report (for wattage) to the associated device (Group Lifeline). Size: 4 Byte, Default Value: 30
Setting | Description |
---|---|
5 - 2678400 | The time for sending a meter report |
0 | The function is disabled. |
The time interval of sending Meter Report (for kWh) to the associated device (Group Lifeline). Size: 4 Byte, Default Value: 300
Setting | Description |
---|---|
5 - 2678400 | The time for sending a meter report |
0 | The function is disabled. |
The time interval of sending Meter Report (for voltage) to the associated device (Group Lifeline). Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
5 - 2678400 | The time for sending a meter report |
0 | The function is disabled |
The time interval of sending Meter Report (for voltage) to the associated device (Group Lifeline). Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | The function is disabled |
5 - 2678400 | The time for sending a meter report |
Smart Plug keep detecting the load current, once the current exceeds 16.5A for more than 5 seconds, smart plug's load will turn off. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | The function is disabled |
1 | The function is enabled |
Define Smart Plugs load status after re-power on. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | last status |
1 | Always on |
2 | Always off |
Smart Plug can send notifications to association device (Group Lifeline) when state of smart plugs load changed. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | The function is disabled. |
1 | Send BASIC REPORT |
2 | Send BASIC REPORT only when Load condition is changed not by Z-WAVE Command, such as short pressing. |
After Smart Plug being included into a Z-Wave network, the LED in the device will indicate the Smart Plugs load status. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | The LED will follow the status (on/off) of its load |
1 | When the state of Switchs load changed, The LED will follow the status (on/off) of its load, but the red LED will turn off after 5 seconds if there is no any switch action. |
Hardware Platform | ZM5202 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.03 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-16065124 |
Z-Wave Product Id | 0x0208.0x0101.0x0005 |
Firmware Updatable | Updatable by Consumer by RF |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |