A. Confirm that a device must be wireless access to Z-Wave network. (Fn Display: Green LED OFF)B. Set NW Inclusion or Node Add by controller.C. Press Fn switch 3 times in a row to include device to Z-Wave network. (Fn Display: Green LED blinking)Press Fn switch 3 times in a row to cancel during including Z-Wave network.(Fn Display: Green LED OFF)D. Confirm that a device is including to Z-Wave network. (Fn Display: Green LED blinking)
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
This Energy meter monitors the total energy usage of an entire home or office and reports immediate wattage and kWh usage data to a Z-Wave controller.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. Press Fn switch over 10~15 sec to initialize connecting network information.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus LifelineUsing meter report, report Meter data of Clamp 1, Clamp2. |
2 | 5 | Using meter report, report the Meter data of Clamp1. |
3 | 5 | Using meter report, report the meter data of Clamp2. |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
GRCCSGroup1 Report Command Class SetupGroup1 report CRC16( Group report crc16 enable/disable)0x00Group report CRC16 Disable0x01Group report CRC16 EnableMeter Report Scale Select( select the scale which is used for Meter report event)0x00Meter report command scale (kWh)0x02Meter report command scale (Watt) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Group1 report CRC16 |
0 - 2 | Meter Report Scale Select |
GRCCSGroup2 Report Command Class SetupGroup2 report CRC16( Group report crc16 enable/disable)0x00Group report CRC16 Disable0x01Group report CRC16 EnableMeter Report Scale Select( select the scale which is used for Meter report event)0x00Meter report command scale (kWh)0x02Meter report command scale (Watt) Size: 4 Byte, Default Value: 2
Setting | Description |
---|---|
0 - 1 | Group2 report CRC16 |
0 - 2 | Meter Report Scale Select |
GRCCSGroup3 Report Command Class SetupGroup3 report CRC16( Group report crc16 enable/disable)0x00Group report CRC16 Disable0x01Group report CRC16 EnableMeter Report Scale Select( select the scale which is used for Meter report event)0x00Meter report command scale (kWh)0x02Meter report command scale (Watt) Size: 4 Byte, Default Value: 2
Setting | Description |
---|---|
0 - 1 | Group3 report CRC16 |
0 - 2 | Meter Report Scale Select |
Set the Interval time of Report group1 (60~65535 second) Size: 4 Byte, Default Value: 720
Setting | Description |
---|---|
60 - 65535 | Set the Group1 Report Time |
Set the Interval time of Report group2 (60~65535 second) Size: 4 Byte, Default Value: 720
Setting | Description |
---|---|
60 - 65535 | Set the Group2 Report Time |
Set the Interval time of Report group3 (60~65535 second) Size: 4 Byte, Default Value: 720
Setting | Description |
---|---|
60 - 65535 | Set the Group3 Report Time |
AMRC (Automatically meter report control) is the report mode setting for Meter data.00b : Clear Meter Report.01b : Report the event in case value is bigger than Parameter 91~96.Report interval is 31 seconds after triggering.10b : Automatic Report with the set interval in Parameter 111~113. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 - 1 | Automatically meter report control |
Reset to the default configuration parameter2 : Initialize Parameter 23 : Initialize Parameter 391 :Initialize Parameter 9192 :Initialize Parameter 9293 :Initialize Parameter 9394 : Initialize Parameter 9495 : Initialize Parameter 9596 :Initialize Parameter 96101 : Initialize Parameter 101102: Initialize Parameter 102103: Initialize Parameter 103111: Initialize Parameter 111112: Initialize Parameter 112113: Initialize Parameter 113255: Reset all parameters to the default Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
2 - 255 | Initialize Parameter |
Meter report clamp select (MRCS) sets the Meter data which is reported by Get command of Meter Command Class that does not use Multi Channel Command Encapsulation Command (without Destination End Point).0x01 : Clamp1 meter data0x02 : Clamp2 meter data0x03 : Sum of the Meter datas Clamp 1, 2 Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 3 | Meter report clamp select |
Group1 Watt Trigger level valueSet the trigger value (0~65535) of Meter report in the Parameter 2 Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 65535 | Set the trigger value |
Group1 kWh Trigger level valueSet the trigger value (0~65535) of Meter report in the Parameter 2 Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 65535 | Set the trigger value |
Group2 Watt Trigger level valueSet the trigger value (0~65535) of Meter report in the Parameter 2 Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 65535 | Set the trigger value |
Group2 kWh Trigger level valueSet the trigger value (0~65535) of Meter report in the Parameter 2 Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 65535 | Set the trigger value |
Group3 Watt Trigger level valueSet the trigger value (0~65535) of Meter report in the Parameter 2 Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 65535 | Set the trigger value |
Group3 kWh Trigger level valueSet the trigger value (0~65535) of Meter report in the Parameter 2 Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 65535 | Set the trigger value |
Hardware Platform | ZM5101 |
Device Type | Whole Home Meter - Simple |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.00 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-16095220 |
Z-Wave Product Id | 0x0242.0x0003.0x0013 |
Color | White |
Firmware Updatable | Updatable by Consumer by RF |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |