This is a
Push A (Add/Remove/Reset) button once.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Z-Works Heat Beat Sensor is a compact Z-Wave Plus compatible device that can monitor up to 3 meters heart rate, breathing rate and activity of an individual. Once plugged to the wall, the sensor relies on 24 GhZ-frequency wave to analyze internal body movement and collect one's vital data. It can be used for example to ensure that a person laying in a bed is alive at night. Thanks to its 1/4" diameter socket used by the large majority of cameras, it can be attached to most tripods and suction pads for an easy installation.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Press A (Add/Remove/Reset) button for at least 10 seconds and release. The Vital Sensor will send the Device Reset Locally command and reset all settings to the factory default. Reset cannot be aborted. Please use this procedure only when the network primary controller is missing or otherwise inoperable.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Control the LED of the device. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | LED Off |
1 | LED On |
Sensor Sensitivity setting. If parameter 10 is set to 0 (high sensitivity mode), the sensor becomes more vulnerable to environmental noise. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | high |
1 | low |
Calibration mode setting. If parameter 11 is set to 0 (manual mode), the sensor will use preset values as thresholds for detecting Heart Rate / Respiratory Rate. If set to 1 (calibration mode), the sensor will use the calibrated values instead. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | manual |
1 | calibration |
Heart rate type setting. Set this to 0 when the target persons average heart rate is over 70. Set it to 1 when its below 70. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | average over 70 |
1 | average below 70 |
Heart Rate/Respiratory Rate sensitivity setting. If parameter 13 is set to 0, it becomes more vulnerable to environmental noise so it becomes more likely that the sensor reports fictitious non-zero Heart Rate and/or Respiratory Rate even if the target person is absent. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | high |
1 | low |
When this parameter is set to 1, the calibration will be started. No response for CONFIGURATION_GET command for this parameter. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | Start calibration |
This can be used to get the calibration status by CONFIGURATION_GET command. Cannot set this parameter value. When power on the sensor, the status becomes 0: Not calibrated. Once calibration starts, the status becomes 1: Calibration in progress and changes to 2: Calibration done when the calibration finishes.If the status becomes 3: Error in calibration, you need to start calibration again. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Not calibrated |
1 | Calibration in progress |
2 | Calibration done |
3 | Error in calibration |
This parameter can be used to get the averaging body / respiratory ratio for past 30 seconds. The configuration value contains three 10 seconds average body / respiratory ratio divided by 8 in 10-bits length for each.Averaging Body / Respiratory Ratio = each 10-bits value x 8Cannot set this parameter value. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1023 | Bit 0 to 9 is latest 10 seconds average value |
0 - 1048575 | Bit 10 to 19 is the average value until 11 seconds before from 20 seconds before. |
0 - 1073741823 | Bit 20 to 29 is the average value until 21 seconds before from 30 seconds before. |
Time interval for auto report Heart Rate. Size: 1 Byte, Default Value: 6
Setting | Description |
---|---|
0 | Auto report off |
6 - 120 | Time interval (x5 seconds) |
Time interval for auto report Respiratory rate. Size: 1 Byte, Default Value: 6
Setting | Description |
---|---|
0 | Auto report off |
6 - 120 | Time interval (x5 seconds) |
Averaging Window Size for Notification Report. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 - 8 | Window size interval (x5 seconds) |
The value of the Body/Respiratory ratio can take around 1000 to 8000. If there is no body motion, the value will be extremely near 1000. The default value of 2000 is typical for rolling over on bed (it depends on the person).This threshold is used for the event of the Posture Change of NOTIFICATION_REPORT. Size: 2 Byte, Default Value: 2000
Setting | Description |
---|---|
1000 - 8000 | Threshold value |
The high threshold for Heart Rate will be used to automatically send Multilevel report of heart rate if the calculated heart rate goes over this value. Size: 2 Byte, Default Value: 100
Setting | Description |
---|---|
0 | Threshold deactivated |
1 - 200 | High-threshold |
The low threshold for Heart Rate will be used to automatically send Multilevel report of heart rate if the calculated heart rate goes below this value. Size: 2 Byte, Default Value: 60
Setting | Description |
---|---|
0 | Threshold deactivated |
1 - 200 | Low-threshold |
The high threshold for Respiratory Rate will be used to automatically send Multilevel report of Respiratory rate if the calculated Respiratory rate goes over this value. Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
0 | Threshold deactivated |
1 - 120 | High-threshold |
The low threshold for Respiratory Rate will be used to automatically send Multilevel report of Respiratory rate if the calculated Respiratory rate goes below this value. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 | Threshold deactivated |
1 - 120 | Low-threshold |
Hardware Platform | SD3502 |
Device Type | Notification Sensor |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 4.33:01.00:00.71 |
Z-Wave Version | 6.61.00 |
Certification ID | ZC10-16115313 |
Z-Wave Product Id | 0x024D.0x0002.0x0002 |
Sensors | Heart RateRespiratory Rate |
Color | White |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |