Connect module to power supply (with temperature sensor connected - if purchased),enable add/remove mode on main controllerauto-inclusion (works for about 5 seconds after connected to power supply) orpress service button S for more than 2 second orpress push button I1 three times within 3s (3 times change switch state within 3 seconds).NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply.NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply, connect the sensor and re-include the module.
Z-Wave ist der internationale Funkstandard zur Kommunikation von Geräten im intelligenten Haus. Dies ist ein Z-Wave Gerät und nutzt die im Quickstart angegebene Funkfrequenz.
Dank Z-Wave können Produkte unterschiedlicher Hersteller miteinander in einem Funknetz verwendet werden. Damit ist auch dieses Produkt mit beliebigen anderen Produkten anderer Hersteller in einem gemeinsamen Z-Wave Funknetz einsetzbar.
Wenn ein Gerät die spezielle sichere Kommunikation unterstützt dann wird es immer dann mit einem anderen Gerät sicher kommunizieren, wenn dieses Gerät auch eine sichere Kommunikation unterstützt. Ansonsten wird aus Kompatibilitätsgründen auf einen normalen Kommunikation umgeschaltet.
Weitere Informationen wie Produktneugkeiten, Tutorials, Supportforen etc. erhalten Sie auf www.zwave.de.
The Qubino Flush Dimmer 0-10V is a universal dimmer with a standard 0-10V output and a multi-function input, which may be a push button or switch, a potentiometer or a 0-10V signal. It also measures power consumption and supports the connection of a digital temperature sensor.
Bitte lesen Sie die Benutzeranleitung bevor Sie das Gerät in Betrieb nehmen.
Damit ein Z-Wave zu einem neuen Netz hinzugefügt werden kann muss es sich im Auslieferungs- oder Reset-Zustand befinden. Im Zweifel ist es sinnvoll, eine Exklusion durchzuführen, um das Gerät ganz sicher in diesem Zustand zu bringen. Diese Exklusion kann von jedem beliebigen Z-Wave Controller durchgeführt werden.
Dieses Gerät kann auch ohne Hilfe eines Controller in den Reset-Zustand zurückgeführt werden. Dies sollte jedoch nur dann gemacht werden wenn der Primärcontroller des Z-Wave-Netzes nicht mehr verfügbar oder defekt ist.
Press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply orpress service button S (only applicable for 24 V SELV supply voltage)for more than 6 second.Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Achtung: Je nach nationalen Sicherheitsnormen kann es nur autorisierten und/oder ausgebildeten Techniker erlaubt sein, elektrische Installationen am Spannungsnetz vorzunehmen. Bitte informieren Sie sich vor der Installation über die Rechtslage.
Im Auslieferungszustand ist das Gerät mit keinem Z-Wave-Netz verbunden. Damit es
mit anderen Z-Wave Geräten kommunizieren kann, muss es in ein bestehendes Z-Wave Netz
eingebunden werden. Dieser Prozess wird bei Z-Wave Inklusion genannt. Geräte können
Netzwerke auch wieder verlassen. Dieser Prozess heißt bei Z-Wave Exklusion. Beide
Prozesse werden von einem Controller gestartet, der dazu in einen Inklusion- bzw.
Exklusion-Modus geschaltet werden muss. Das Handbuch des Controllers enthält
Informationen, wie er in diese Modi zu schalten ist. Erst wenn der Controller
des Z-Wave Netzes im Inclusion-Modus ist, können Geräte hinzugefügt werden.
Das Verlassen des Netzes durch Exklusion führt zum Rücksetzen dieses Gerätes
in den Auslieferungszustand.3>
Inklusion
Connect module to power supply (with temperature sensor connected - if purchased),enable add/remove mode on main controllerauto-inclusion (works for about 5 seconds after connected to power supply) orpress service button S for more than 2 second orpress push button I1 three times within 3s (3 times change switch state within 3 seconds).NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply.NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply, connect the sensor and re-include the module.
Exklusion
Connect module to power supply bring module within maximum 1 meter (3 feet) of the main controller,enable add/remove mode on main controller,press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply orpress service button S (only applicable for 24 V SELV supply voltage)for more than 6 second.By this function all parameters of the module are set to default values and own ID is deleted.If push button I1 is pressed three times within 3s (or service button S is pressed more than 2 and less than 6 seconds) module is excluded, but configuration parameters are not set to default values. NOTE 1: If the module is included with parameter 1 value 3, 4 or 5 and module reset is done, wait at least 30s before next inclusion.NOTE 2: Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Die folgenden kleinen Hinweise können bei Problemen im Z-Wave Netz helfen.
Z-Wave Geräte können andere Geräte direkt steuern. Diese direkte Steuerung heißt in Z-Wave Assoziation. In den steuernden Geräten muss dazu die Geräte-ID des zu steuernden Gerätes hinterlegt werden. Dies erfolgt in sogenannten Assoziationsgruppen. Eine Assoziationsgruppe ist immer an ein Ereignis im steuernden Gerät gebunden (Tastendruck oder Auslösen eines Sensors). Bei Eintritt dieses Ereignisses wird an alle in einer Assoziationsgruppe hinterlegten Geräte ein Steuerkommando - meist ein BASIC SET - gesendet.
Gruppen-Nummer | Max. Anzahl Geräte | Beschreibung |
---|---|---|
1 | 1 | Z-Wave Plus Lifeline |
2 | 16 | Basic On/Off |
3 | 16 | Start Level Change/Stop Level Change |
4 | 16 | Multilevel Set |
5 | 16 | Multilevel Sensor Report (triggered at change of analogue sensor) |
6 | 16 | Multilevel Sensor Report (triggered at change of temperature sensor) |
Z-Wave Produkte können direkt nach der Inklusion im Netz verwendet werden. Durch Konfigurationseinstellungen kann das Verhalten des Gerätes jedoch noch besser an die Anforderungen der Anwendung angepasst und zusätzliche Funktionen aktiviert werden.
WICHTIG: Manche Steuerungen erlauben nur die Konfiguration von vorzeichenbehafteten Werten zwischen -128 und 127. Um erforderliche Werte zwischen 128 und 255 zu programmieren, muss der gewünschte Wert minus 256 eingegeben werden. Beispiel: um einen Parameter auf einen Wert von 200 zu setzen, müsste der Wert 200-256 = -56 eingegeben werden, wenn nur positive Werte bis 128 akzeptiert werden. Bei Werten von 2 Byte Länge wird die gleiche Logik angewandt: Werte über 32768 werden als negative Werte angegeben.
By this parameter the user can set input based on device type (switch, potentiometer, 0-10V sensor,..). NOTE: After parameter change to value 3, 4 or 5 first exclude module (without setting parameters to default value) then wait at least 30s and then re include the module! Grösse: 1 Byte, Voreingestellt: 0
Wert | Beschreibung |
---|---|
1 | Bi-stable switch type |
3 | 0-10V Temperature sensor (regulated output) |
4 | 0-10V Illumination sensor (regulated output) |
2 | Potentiometer (Flush Dimmer 0-10Vis using set value the last received from potentiometer or from z-wave controller) |
0 | Default value - Mono- stable switch type (push button)button quick press turns between previous set dimmer value and zero) |
5 | 0-10V General purpose sensor (regulated output) |
Flush Dimmer 0-10V module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. Grösse: 2 Byte, Voreingestellt: 255
Wert | Beschreibung |
---|---|
2 | ALL ON active, ALL OFF is not active |
255 | Default value - ALL ON active, ALL OFF active |
0 | ALL ON is not active, ALL OFF is not active |
1 | ALL ON is not active, ALL OFF active |
Turns off the output after set time. Grösse: 2 Byte, Voreingestellt: 0
Wert | Beschreibung |
---|---|
0 | Default value - Auto OFF disabled |
1 - 32536 | = 1second - 32536 seconds Auto OFF enabled with define time, step is 1 second |
Set value is added or subtracted to actual measured value by sensor. Grösse: 2 Byte, Voreingestellt: 32536
Wert | Beschreibung |
---|---|
32536 | Default value - offset is 0.0 degrees celsius |
1 - 100 | Value from 0.1 degrees celsius to 10.0 degrees celsius is added to actual measured temperature |
1001 - 1100 | Value from -0.1 degrees celsius to -10.0 degrees celsius is subtracted to actual measured temperature |
Turns on the output after set time. Grösse: 2 Byte, Voreingestellt: 0
Wert | Beschreibung |
---|---|
0 | Default value - Auto ON disabled |
1 - 32535 | = 1second - 32535 seconds Auto ON enabled with define time, step is 1 second |
Digital temperature sensor reportingIf digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. Available configuration parameters (data type is 1 Byte DEC):default value 5 = 0,5C change0 - Reporting disabled1 - 127 = 0,1C - 12,7C, step is 0,1C Grösse: 1 Byte, Voreingestellt: 5
Wert | Beschreibung |
---|---|
5 | Default value = 0,5 degrees celsius change |
0 | Reporting disabled |
1 - 127 | 0,1 degrees celsius - 12,7 degrees celsius, step is 0,1 degrees celsius |
Input I1 Sensor reportingIf analogue sensor is connected, module reports measured value on change defined by this parameter. Grösse: 2 Byte, Voreingestellt: 5
Wert | Beschreibung |
---|---|
5 | Default value = 0,5 change |
0 | Reporting disabled |
1 - 10000 | = 0,1 - 1000 step is 0,1 |
Parameter is associated with Association group No. 2. Below this value, the Association No. 2 will report Basic Set 0xFF and above this value will report Basic Set 0xFF. Basic Set is reported only, when the input value changes for more than 10% (1V). Grösse: 1 Byte, Voreingestellt: 5
Wert | Beschreibung |
---|---|
5 | Default value = 5 (0,5V) |
1 - 100 | 0,1 - 10V |
Value that must correspond to minimum sensor range value. Valid only if parameter 1 is set to values 3, 4 or 5). Available configuration parameters (data type is 2 Byte DEC):default value 0 = 0.0C / 0Lux / 0.0%rh0 - 10000value from 0 to 1000(resolution 0,1)1000120000value from -0,1 to-1000(resolution 0,1)NOTE: Minimum value must not be higher than maximum value! Grösse: 2 Byte, Voreingestellt: 0
Wert | Beschreibung |
---|---|
0 | Default value 0 = 0.0 degrees celsius / 0Lux / 0.0%rh |
0 - 10000 | Value from 0 to 1000(resolution 0,1) |
10001 - 20000 | Value from -0,1 to-1000(resolution 0,1)alue from -0,1 to-1000(resolution 0,1) |
Value that must correspond to maximum sensor range value. Valid only if parameter 1 is set to values 3, 4 or 5). NOTE: Maximum value must not be lower than minimum value! Grösse: 2 Byte, Voreingestellt: 1000
Wert | Beschreibung |
---|---|
10001 - 20000 | Value from -0,1 to-1000(resolution 0,1) |
1000 | Default value - 1000 = 100.0 degrees celsius / 100Lux / 100%rh |
0 - 10000 | Value from 0 to 1000(resolution 0,1) |
If Double click function is enabled, a fast double click on the push button will set dimming power at maximum dimming value. Valid only if input is set as mono-stable (push button). Grösse: 1 Byte, Voreingestellt: 0
Wert | Beschreibung |
---|---|
0 | Default value - Double click disabled |
1 | Double click enabled |
A Flush dimmer supports secure and unsecure inclusion. Even if the controller does not support security command classes, a dimmer could be included as unsecure and keep all the functionality. Grösse: 1 Byte, Voreingestellt: 0
Wert | Beschreibung |
---|---|
0 | Default value - Unsecure Inclusion |
1 | Secure Inclusion |
Based on the parameter settings the stores/does not store the last value of the output after power failure. Grösse: 1 Byte, Voreingestellt: 0
Wert | Beschreibung |
---|---|
0 | Default value - Flush Dimmer 0-10V module saves its state before power failure (it returns to the last position saved before a power failure) |
1 | Flush Dimmer 0-10V module does not save the state after a power failure, it returns to "off" position |
This parameter is influencing on the software only when the value of parameter number 1 is set to value 3, 4 or 5. In manual mode regulation (how the input influence on output) is disabled. Grösse: 1 Byte, Voreingestellt: 0
Wert | Beschreibung |
---|---|
0 | Default value - Manual |
1 | Auto |
NOTE: When ZERO PID inside deadband is forced to zero. LASTVALUE means that PID remains on same level as was before entering into deadband. Grösse: 1 Byte, Voreingestellt: 0
Wert | Beschreibung |
---|---|
0 | Default value - PID value equal ZERO |
1 | PID value set to LAST VALUE |
This parameter defines the zone where PID is not active. If the temperature difference between actual and setpoint is bigger than PID deadband, then the PID will start to regulate the system, otherwise the PID is zero or fixed. Grösse: 1 Byte, Voreingestellt: 1
Wert | Beschreibung |
---|---|
1 | Default value 1 (1%) |
0 - 100 | 0 - 100%, step is 1% |
Parameter defines the time between samples. On each sample the controller capture difference between SP-act. Grösse: 1 Byte, Voreingestellt: 5
Wert | Beschreibung |
---|---|
5 | Default value 5 (5s) |
0 - 127 | = 0s to 127s, step is 1s |
The error is multiplied by a negative (for reverse action) proportional constant P, and added to the current output. P represents the band over which a controller's output is proportional to the error of the system. E.g. for a heater, a controller with a proportional band of 10 deg C and a setpoint of 100 deg C would have an output of 100% up to 90 deg C, 50% at 95 Deg C and 10% at 99 deg C. If the temperature overshoots the setpoint value, the heating power would be cut back further. Proportional only control can provide a stable process temperature but there will always be an error between the required setpoint and the actual process temperature. Grösse: 2 Byte, Voreingestellt: 100
Wert | Beschreibung |
---|---|
0 - 1000 | P value, step is 1 |
100 | Default value |
The error is integrated (averaged) over a period of time, and then multiplied by a constant I, and added to the current control output. I represents the steady state error of the system and will remove setpoint / measured value errors. For many applications Proportional + Integral control will be satisfactory with good stability and at the desired setpoint. Grösse: 2 Byte, Voreingestellt: 1
Wert | Beschreibung |
---|---|
1 | Default value |
0 - 1000 | I value, step is 1 |
The rate of change of the error is calculated with respect to time, multiplied by another constant D, and added to the output. The derivative term is used to determine a controller's response to a change or disturbance of the process temperature (e.g. openingan oven door). The larger the derivative term, the more rapidly the controller will respond to changes in theprocess value. Grösse: 2 Byte, Voreingestellt: 1
Wert | Beschreibung |
---|---|
1 | Default value |
0 - 1000 | D value, step is 1 |
NOTE: The minimum level may not be higher than the maximum level! 1% min. dimming value is defined by Z-Wave multilevel device class. When the switch type is selected as Bi-stable, it is not possible to dim the value between min and max. If Switch_multilevel_set is set to the value 0, the output is turned OFF. If Switch_multilevel_set is set to the value 1, the output is set to the minimum diming value. Grösse: 1 Byte, Voreingestellt: 1
Wert | Beschreibung |
---|---|
1 | Default value= 1% (minimum dimming value) |
1 - 98 | = 1% - 98%, step is 1%. Minimum dimming values is set by entered value |
NOTE: The maximum level may not be lower than the minimum level! 99% max. dimming value is defined by Z-Wave multilevel device class. When the switch type is selected as Bi-stable, it is not possible to dim the value between min and max. Grösse: 1 Byte, Voreingestellt: 99
Wert | Beschreibung |
---|---|
2 - 99 | = 2% - 99%, step is 1%. Maximum dimming values is set by entered value. |
99 | Default value = 99% (Maximum dimming value) |
Set value means time of moving the Flush Dimmer 0-10V between min. and max. dimming values by short press of push button I1 or controlled through UI (BasicSet). Grösse: 2 Byte, Voreingestellt: 100
Wert | Beschreibung |
---|---|
100 | Default value 100 = 1s |
50 - 255 | = 500 mseconds - 2550 mseconds (2,55s), step is 10 mseconds |
Time of moving the Flush Dimmer 0-10V between min. and max dimming values by continues hold of push button I1 or associated device. Grösse: 2 Byte, Voreingestellt: 3
Wert | Beschreibung |
---|---|
3 | Default value 3 = 3s |
1 - 255 | = 1 second - 255 seconds |
This parameter is used with association group 3.A receiving device SHOULD respect the start level if the Ignore Start Level bit is 0. A receiving device MUST ignore the start level if the Ignore Start Level bit is 1. Grösse: 1 Byte, Voreingestellt: 0
Wert | Beschreibung |
---|---|
0 | Default value - Respect start level |
1 | Ignore start level |
This parameter is used with association group 3.The Duration field MUST specify the time that the transition should take from the current value to the new target value. A supporting device SHOULD respect the specified Duration value. Grösse: 1 Byte, Voreingestellt: 0
Wert | Beschreibung |
---|---|
0 | Default value - dimming duration according to parameter 66 |
1 - 127 | From 1 to 127 seconds |
Z-Wave Hardware Platform | ZM5202 |
Gerätetyp | Light Dimmer Switch |
Netzwerkfunktion | Always On Slave |
Firmware Version | HW: 1 FW: 2.03:02.03 |
Z-Wave Version | 6.51.08 |
Zertifizierungs-ID | ZC10-17025448 |
Z-Wave Produkt Id | 0x0159.0x0001.0x0053 |
Supported Meter Type | Electric Energy |
Sensors | Air Temperature |
Electric Load Type | Dimmable LEDELV (Electronic)Incandescent |
Switch Type | Push Button |
Color | Light Blue |
Frequenz | XXfrequency |
Maximale Sendeleistung | XXantenna |