Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action button that you can find on the product's housing.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Aeotec Nano Switch is a Z-Wave Smart Switch specifically used to enable Z-Wave command and control (on/off) of any wall switches. In the event of power failure, non-volatile memory retains all programmed information relating to the units operating status.It can connect to 2 external manual switches to control the load ON/OFF independently. Its surface has a pin socket, which can be used for connecting to the touch panel, so you can also use the touch panel to control the Dual Nano Switch.The Nano Switch is also a security Z-Wave device and supports Over The Air (OTA) feature for the products firmware upgrade.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Press and hold the Action button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline.When the load state of Nano Switch (turn on/off the load) is changed, the Hail CC and Basic Report (configured by parameter 80) can be sent to the associated nodes in this group. |
2 | 5 | Forward the Basic Set, Switch All, Scene Activation Set to associated nodes in Group 2 when the Dual Nano Switch receives the Basic Set, Switch All, Scene Activation Set commands from main controller. (E.g. Send/forward Basic Set to control the other nodes in association Group 2) |
3 | 5 | Send Basic Set (configured by parameter 0x51 ) to the associated nodes in Group 3 when the external switch S1 is operated.Note: The Switch Mode of external switch S1 should be identified successfully, which means that the value of Configuration parameter 0x78 should be non-zero, then the Basic Set can be sent to the associated nodes in Group 3 via triggering the S1 switch. |
4 | 5 | Send Basic Set (configured by parameter 0x52) to the associated nodes in Group 4 when the external switch S2 is operated.Note: The Switch Mode of external switch S2 should be identified successfully, which means that the value of Configuration parameter 0x79 should be non-zero, then the Basic Set can be sent to the associated nodes in Group 3 via triggering the S2 switch. |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Configure the external switch mode for S1. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
2 | 3 way switch mode |
0 | Enter automatic identification mode |
1 | 2-state switch mode |
3 | Momentary push button mode |
Configure the external switch mode for S2. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Enter automatic identification mode |
1 | 2-state switch mode |
2 | 3 way switch mode |
3 | Momentary push button mode |
Set the control destination for external switch Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 | control the output loads of itself. |
2 | control the other nodes |
3 | control the output loads of itself and other nodes. |
Configure the output status after re-power on it. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Always on |
0 | Last status |
2 | Always off |
Lock/unlock configuration parameters. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Unlock |
1 | Lock |
Reset the Nano Switch to factory default. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1431655765 | Reset to factory default setting and removed from the z-wave network |
0 | Reset all configuration parameters to factory default setting |
Output Load will be turned off automatically after 30 seconds and if the temperature of product inside exceeds 100 . Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
To set which notification would be sent to the associated devices (Group 1) when the state of Nano Dimmers load is changed. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 | Send Nothing |
1 | Send Hail CC |
2 | Send Basic Report CC |
3 | Send Hail CC when using the manual switch to change the load state. |
To set which notification would be sent to the associated nodes in association Group 3 when using the external switch 1 to switch the loads. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Send Nothing |
1 | Send Basic Set CC |
To set which notification would be sent to the associated nodes in association Group 4 when using the external switch 2 to switch the loads. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | Send Basic Set CC |
0 | Send Nothing |
Configure the state of LED when it is in 3 modes (Energy mode, Momentary indicate mode, Night light mode) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Energy mode. The LED will follow the status (on/off). |
1 | Momentary indicate mode. When the state of Switchs load changed, the LED will follow the status (on/off) of its load, but the LED will turn off after 5 seconds if there is no any switch action. |
2 | Night light mode. The LED will remain ON state. |
Set the ON/OFF time of the LED when it is in Night light mode. Size: 4 Byte, Default Value: 301991936
Setting | Description |
---|---|
0 - 60 | The minute time of OFF |
256 - 316 | The hour time of OFF |
65536 - 65596 | The minute time of ON |
16777216 - 16777276 | The hour time of ON |
Set the ON time of output load. Size: 4 Byte, Default Value: 8327680
Setting | Description |
---|---|
0 - 60 | The minute value of ON time |
65536 - 65543 | The day value (Mon to Sun) |
16777216 | Enable the setting. |
256 - 316 | The hour value of ON time |
16777215 | Disable the setting. |
Set the OFF time of output load. Size: 4 Byte, Default Value: 8327680
Setting | Description |
---|---|
256 - 316 | The hour value of ON time |
65536 - 65543 | The day value (Mon to Sun) |
16777215 | Disable the setting. |
0 - 60 | The minute value of ON time |
16777216 | Enable the setting. |
Hardware Platform | ZM5101 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 139 FW: 1.01:01.00 |
Z-Wave Version | 6.51.09 |
Certification ID | ZC10-17035522 |
Z-Wave Product Id | 0x0086.0x0203.0x008B |
Switch Type | Toggle |
Z-Wave Scene Type | Scene |
Electric Load Type | Dimmable LEDELV (Electronic)FluorescentIncandescentLEDMLV (Magnetic) |
Firmware Updatable | Updatable by Consumer by RF |
Supported Notification Types | Heat Alarm |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |