This is a
Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer.Pressing Include button three times within 2 seconds will enter inclusion mode.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Using Micromodule Motor Controller user can control connected rollershuttersandblinds,finelyadjusttheirpositionwithhis Z-Wave controller, Z-Wave remote or simple push of a button.MicromoduleMotorControllerisZ-WavePlusenableddevice whichmakesitcompatiblewithanyZ-Waveenablednetwork, regardless of the manufacturer. Slim design makes it easy to fit in majority of wall boxes. New smart-relay calibration technology reduces inrush current caused by the load and enables module to work perfectly with all kinds of roller shutters and blinds. Micromodule is able to detect position of the Shutter by using thepatternedpowermeasuringmethod,soitcanberemote controlled not only fully up or down, but also can be adjusted to ex. 30% or 50%. When manually operated by the push button, Micromodule Motor Controllercanalsomemorizethepositionandsendthenew shutter position to its controller (ex. IP-Gateway).
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Use this procedure only in the event that the network primary controller is missing or otherwise inoperable.Pressing Include button three times within 2 seconds will enter inclusion mode.Within 1 second, press Include button again for 5 seconds until LED is off.IDs are excluded.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | LifelineThere is only one group called Group1, there is only one node for Group1 which support MULTILEVEL_SWITCH_REPORT, METER_REPORT_COMMAND_V3, ALARM_REPORT. |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Ifthesettingisconfiguredfor1hour(setvalue=720),the Micromodulewillreportitsinstantpowerconsumptionevery 1hourtothenodeofcorrespondingGroup.Themaximum intervaltoreportitsinstantpowerconsumptionis45hours (5s*32767/3600=45hr). Default value is 1 hour. Size: 2 Byte, Default Value: 720
Setting | Description |
---|---|
1 - 32767 | 5*720s=3600s=1 hour |
Ifthesettingisconfiguredfor1hour(setvalue=6),the MicromodulewillreportitsAccumulatedPowerConsumption (KW/h)every1hourtothenodeofcorrespondingGroup.The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days). Default value=1 hour. Size: 2 Byte, Default Value: 6
Setting | Description |
---|---|
1 - 32767 | 6*10min= 1 hour |
This is a warning when the wattage of load exceeds the preset thresholdvalue,Ifthesettingvalueis500,whentheload currentoverthisvalue,Micromodulewillsendcurrentmeter reportcommandtothenodeofcorrespondingGroup.Default value=500. Size: 2 Byte, Default Value: 500
Setting | Description |
---|---|
10 - 500 | 500*0.01=5 A |
This is a warning when the KWh of load over the preset threshold value,Ifthesettingvalueis10000,whentheAccumulated PowerConsumptionofRelay1orRelay2overthisvalue, Micromodule will send KWh Meter Report command to the node ofcorrespondingGroup,minimumvalueis1KWhanddefault value is 10000 kWh. Size: 2 Byte, Default Value: 10000
Setting | Description |
---|---|
1 - 10000 | 10000*1KWh=10000KWh |
1.ONE PUSH BUTTONWhen the configuration setting is One Push Button, only S1 input will be valid. The control moving commands can be accepted in this switch type while the shutter is moving. In this switch type, theinclusion/exclusion/reset/associationfunctioncanalsobe fulfilled by pressing S1 just like the operation of include button. WhenS1isshortpressed,theshutterwillmoveuptoward TOP(0xFF). If during this movement S1 is short pressed again, the shutter will stop moving. A third short pressing of S1 will move the shutter down toward BOTTOM(0x00). If during this movement S1 is short pressed again, the shutter will stop moving. And so on Inverting direction and stopping.2.TWO PUSH BUTTON: (THE DEFAULT SETTING IS TWO PUSH BUTTON (2))IfthissettingisconfiguredasTwoPushButton,S1andS2 input will be valid, but will not accept pressing S1 and S2 at the sametime.Inthisswitchtype,theinclusion/exclusion/reset/association function can also be fulfilled by pressing S1 or S2 just like the operation of include button. When S1 is pressed and held more than 1.5 seconds, the shutter will move up toward TOP(0xFF), and the shutter will stop moving when S1 is released. When S2 is pressed and held for more than 1.5 seconds, the shutter will move down toward BOTTOM(0x00), and the shutter will stop moving when S2 is released.WhenS1isshortpressed,theshutterwillmoveuptoward TOP(0xFF). If during this movement S1 i short pressed again S1 again, the shutter just keep moving up toward TOP(0xFF). The easy way to stop this moving is short pressing S2. When S2 is short pressed, the shutter will move down toward BOTTON(0x00). If during this movement S2 is short pressed again S2 again, the shutter just keep moving down toward BOTTON(0x00). The easy way to stop this moving is short pressing S1. When in Two Push Button switch type, S1 or S2 are pressed and not released, and PAN08 receive any control moving command from Z-Wave RF (Ex. BASIC_SET, BINARY_SWITCH_SET, MULTILEVEL_SWITCH_SET, MULTILEVEL_SWITCH_START_LEVEL_CHANGE or MULTILEVEL_SWITCH_STOP_LEVEL_CHANGEorSCENE_ACTIVATION_SET),PAN08wontdoanychangeinpositionbut report alarm to Group1 (Alarm_Type=1, Alarm_level =0xFF), this indicate that the S1 or S2 not been release. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | 1: One Push button |
2 | 2:Two Push button |
Mode 1 : In 5 seconds period after controlled by a moving command, it will report the destination level when received request command. Out of the 5 seconds period, it will report the actual level of the shutter when received request command.Mode 2 : Whenever the shutter moves past a 10 percent level, it will auto report the level to Group 1 node. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
1 | 1:Report destination level in 5s |
2 | 2:Report 10 percent level while running |
Hardware Platform | SD3502 |
Device Type | Window Covering - Pos/End Aware |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.04 |
Z-Wave Version | 6.51.02 |
Certification ID | ZC10-17055604 |
Z-Wave Product Id | 0x0131.0x0001.0x0015 |
Firmware Updatable | Updatable by Consumer by RF |
Electric Load Type | Incandescent |
Neutral Wire Required | ok |
Supported Meter Type | Electric Energy |
Color | White |
Window Covering Control Features | Endpoint AwareManual CalibrationPosition AwareSupports CurtainsSupports Up/Down Motion |
Loads Controlled | 2 |
Switch Type | Push Button |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |