This is a
1. Press & hold action button for 5 seconds when siren is in the excluded status2. LED of siren will be on 5 seconds later3. Siren will try inclusion for 1 minute when action button is released4. LED will blink 3 times with 250ms interval if inclusion is successful
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Siren will detect the movement of people or animals in real time and then report it to Z-Wave gateway (LTE Router) through the Z-Wave protocol.It Will be used with AA Battery, Battery life time is 1year.And it can be installed easily by using double side tape.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
1. Press the action button for 10 seconds2. The Green LED is turned on after pressing 10 seconds of the action button3. If the Device is removed (factory reset), the Green LED blinks 5 times Please use this procedure only when the network primary controller is missing or otherwise inoperable
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In order to communicate with the device, a static controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time is significantly decreased.
This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbox. Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static controller this controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the device. To wakeup the device please perform the following action: The device can be made to wake-up prior to the normal wake-up interval by pressing the action button.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
| Group Number | Maximum Nodes | Description |
|---|---|---|
| 1 | 5 | Lifeline Association Group supporting up to 5 nodes. |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Enables or Disables the alarm function. To enable, use the hex value 0xFF which is -128. Size: 1 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 0 | Alarm function off |
| -128 | Alarm function on |
- 0x00 : Mute - 0x01 : Level 1 - 0x02 : Level 2 - 0x03 : Level 3 - 0x04 : Level 4 - 0x05 : Level 5 (Max) Size: 1 Byte, Default Value: 1
| Setting | Description |
|---|---|
| 0 | The alarm sound is muted |
| 1 - 5 | The alarm sound is set to level 1 through 5 (Maximum) |
This parameter sets the time that the alarm will operate when it is triggered. Size: 1 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 0 | 1 Minute |
| 1 | 5 Minutes |
| 2 | 10 Minutes |
| 3 | 15 Minutes |
| 4 | 20 Minutes |
This parameter provides a 3 second preview of the alarm sound. Use value -128 or hex value 0xFF. Size: 1 Byte, Default Value: 0
| Setting | Description |
|---|---|
| -128 | Alarm operating (3 sec) |
| Hardware Platform | ZM5101 |
| Device Type | Siren |
| Network Operation | Listening Sleeping Slave |
| Firmware Version | HW: 18 FW: 39.36 |
| Z-Wave Version | 6.61.00 |
| Certification ID | ZC10-17065638 |
| Z-Wave Product Id | 0x022C.0x004E.0x0001 |
| Supported Notification Types | Emergency AlarmHome Security |
| Firmware Updatable | Updatable by Professional/Technician |
| Color | White |
| Switch Type | Push Button |
| IP (Ingress Protection) Rated | ok |
| Outdoor Use | ok |
| Frequency | XXfrequency |
| Maximum transmission power | XXantenna |