This is a secure Remote Control (Audio) for CEPT (Europe). Please make sure the internal battery is fully charged. To add this device to your network execute the following action:
Put the Z-Wave Controller in inclusion mode. Hold down the central key, then press the top-right key 3 times within 1.5 seconds to enter inclusion mode. Aftersuccessfulinclusion,thedevicewillwaketoreceivethe setting command from Z-Wave Controller in about 20 seconds.

Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.


Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.

This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.

If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.

Product Description

Zipato Z-Wave Remote is a simple controller for controlling AV device through Z-Wave-to-IR extender, and it can also control 8 ON/OFF lighting groups via basic set, based on Z-Wave technology. It is the Z-Waveplusproduct,itsupportthesecurity,OTA...allthe newestfeatures of the Z-Wave technology.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.

Usethisprocedureonlyintheeventthattheprimary controller is lost or otherwise inoperable.Hold down the central key, then press the top-right key 4 times within 1.5 seconds and during 4th press, hold the key until LED lights up. After 3 seconds the LED will turn OFF, and after next 2 seconds, release the tamper key. If successful, the LED will light ON for second. Otherwise, the LED will flash once. IDs are excluded and all settings will reset to factory default.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.

Inclusion

Put the Z-Wave Controller in inclusion mode. Hold down the central key, then press the top-right key 3 times within 1.5 seconds to enter inclusion mode. Aftersuccessfulinclusion,thedevicewillwaketoreceivethe setting command from Z-Wave Controller in about 20 seconds.

Exclusion

Put the Z-Wave Controller in exclusion mode. Hold down the central key, then press the top-right key 3 times within 1.5 seconds to enter exclusion mode. Node ID has been excluded.

Communication to a Sleeping device (Wakeup)

This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In order to communicate with the device, a static controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time is significantly decreased.

This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbox. Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static controller this controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the device. To wakeup the device please perform the following action: After the device is added to the network, it will wake-up once per day in default. When it wakes up it will broadcast the Wake Up Notification message to the network, and wake-up 10 seconds to receive the setting commands. To wake-up the device immediately, please hold down the central key, then press the top-right key once within. The device will wake-up for 10 seconds.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association - one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.

Association Groups:

Group Number Maximum Nodes Description
1 4 Z-Wave Plus Lifeline
2 4 Lighting group control
3 4 Lighting group control
4 4 Lighting group control
5 4 Lighting group control
6 4 Lighting group control
7 4 Lighting group control
8 4 Lighting group control
9 4 Lighting group control

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.

IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.

Parameter 10: Auto Report Battery Time

The interval time for auto report the battery level.
Size: 1 Byte, Default Value: 12

Setting Description
0 - 127 0 means turn off auto report battery.Each tick means 30 minutes.The default value is 12(6 hours).

Parameter 2: Basic Set Level

Setting the BASIC command value to turn on the light. The xFF(-1) means turn on the light. For dimmer equipment 1 to 100 means the light strength. 0 means turn off the light.
Size: 1 Byte, Default Value: -1

Setting Description
-128 - 127 Setting the BASIC command value to turn on the light.

Parameter 7: Customer Function

Customer function switch, using bit control.
Size: 1 Byte, Default Value: 0

Setting Description
1 Switch AV control/ Lighting group control.

Parameter 82: Association Group 2 Basic Set Level

Setting the BASIC command value to turn on the light in the association group 2.
Size: 1 Byte, Default Value: 0

Setting Description
-128 - 127 0 means using the value of configuration 2 to set.

Parameter 83: Association Group 3 Basic Set Level

Setting the BASIC command value to turn on the light in the association group 3.
Size: 1 Byte, Default Value: 0

Setting Description
-128 - 127 0 means using the value of configuration 2 to set.

Parameter 84: Association Group 4 Basic Set Level

Setting the BASIC command value to turn on the light in the association group 4.
Size: 1 Byte, Default Value: 0

Setting Description
-128 - 127 0 means using the value of configuration 2 to set.

Parameter 85: Association Group 5 Basic Set Level

Setting the BASIC command value to turn on the light in the association group 5.
Size: 1 Byte, Default Value: 0

Setting Description
-128 - 127 0 means using the value of configuration 2 to set.

Parameter 86: Association Group 6 Basic Set Level

Setting the BASIC command value to turn on the light in the association group 6.
Size: 1 Byte, Default Value: 0

Setting Description
-128 - 127 0 means using the value of configuration 2 to set.

Parameter 87: Association Group 7 Basic Set Level

Setting the BASIC command value to turn on the light in the association group 7.
Size: 1 Byte, Default Value: 0

Setting Description
-128 - 127 0 means using the value of configuration 2 to set.

Parameter 88: Association Group 8 Basic Set Level

Setting the BASIC command value to turn on the light in the association group 8.
Size: 1 Byte, Default Value: 0

Setting Description
-128 - 127 0 means using the value of configuration 2 to set.

Parameter 89: Association Group 9 Basic Set Level

Setting the BASIC command value to turn on the light in the association group 9.
Size: 1 Byte, Default Value: 0

Setting Description
-128 - 127 0 means using the value of configuration 2 to set.

Technical Data

Hardware Platform SD3502
Device Type Remote Control - AV
Network Operation Portable Slave
Firmware Version HW: 1 FW: 1.12:01.05
Z-Wave Version 6.51.02
Certification ID ZC10-17065643
Z-Wave Product Id 0x0131.0x0008.0x001D
Supported Notification Types Emergency Alarm
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Association Grp Info
  • Association V2
  • Battery
  • Configuration
  • Device Reset Locally
  • Firmware Update Md V2
  • Manufacturer Specific V2
  • Notification V4
  • Powerlevel
  • Security
  • Version V2
  • Wake Up V2
  • Zwaveplus Info V2

Controlled Command Classes

  • Basic
  • Simple Av Control

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways,Remote Controls or battery operated wall controllers.
  • Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators and even remote controls.
  • Primary Controller — is the central organizer of the network. It must be a controller. There can be only one primary controller in a Z-Wave network.
  • Inclusion — is the process of adding new Z-Wave devices into a network.
  • Exclusion — is the process of removing Z-Wave devices from the network.
  • Association — is a control relationship between a controlling device and a controlled device.
  • Wakeup Notification — is a special wireless message issued by a Z-Wave device to announces that is able to communicate.
  • Node Information Frame — is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.