This is a
Add the Device (Smart Plug) to ZWave Network1.Make sure the sensor is powered. 2.Set ZWave controller or ZWave gateway into inclusion mode (Refer to the controller or gateway operating manual) 3.Press the button three times within 1.5 second, the device will enter inclusion mode. And the LED will flash on and off with green alternately five times within 2 seconds.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
This product can be included and operated in any ZWave network with other ZWave certified devices from other manufacturers and/or other applications. All nonbattery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.In the front casing, there is button that is used to carry out include, exclude or reset factory default settings on PCB Board.When power is first supplied, the LED will flash on and off with yellow alternately every 1 second intervals within 5 seconds if the detector has not been added a ZWave network, otherwise the LED will flash on and off 5 times with cyan alternately every 300 millisecond. Please get familiar with the terms below before starting the operations.This Plug has function that remembers the relay states, the plug will turn on after power up next time if the plug is turn on before the power cutoff.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Note:to use the reset procedure only when the primary controller is missing or inoperable.Restore the Device (Smart Plug) to Factory Default SettingsReset procedure will delete all information on the ZWave network and ZWave controller or ZWave Gateway, and restore the sensor to factory default settings.1.Make sure the sensor is powered. 2.Press and hold the button more than 10 seconds until the LED blink with red color. 3.Release the button.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | GROUP 1 is lifeline service that assigned to plug statusON/OFF. It enables the Plug to send reports and readings to ZWave Controller or ZWave Gateway. This Group Support:NOTIFICATION_REPORT_V4 METER_REPORT_V4 SWITCH_BINARY_REPORT DEVICE_RESET_LOCALLY_NOTIFICATION |
2 | 5 | GROUP 2 allows for sending control commands to associated devices such as Siren, relay module, lighting, etc. If current load is over the max current defined in parameter #3, the Plug will send a BASIC_SET (0xFF) to associated devices. When current load is normal, plug will send a BASIC_SET (0x00) to associated devices. This Group Support:BASIC_SET |
3 | 5 | GROUP 3 allows for Send Notification to associated devices in this group. This Group Support: NOTIFICATION_REPORT_V4 |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
This parameter defines Disable/Enable meter report measure data to controller. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable Report |
1 | Enable Report |
This parameter defines the button on/off function is enabled or not on the top of the wall plug. This parameter can be configured 0 and 1. If this parameter is set to 1, users can turn on and off the wall plug by pressing the button on the top of the wall plug. If this parameter is set to 0, the wall plug cannot be turned on and off by pressing the button. Size: 1 Byte, Default Value: 1
Setting | Description |
---|
This parameter defines interval time (in seconds) that Meter report data to main controller. Size: 2 Byte, Default Value: 300
Setting | Description |
---|---|
1 - 65535 | s |
This parameter defines maximum current the plug can provide to load that be connected to plug. If the current consumed by load is greater than maximum current, the plug will cut off power, and send NOTIFICATION_EVENT_POWER_MANAGEMENT_OVER_LOAD_DETECTED to associated devices in lifeline. Red Led will blink every seconds until current is normal (less than Parameter #3). You must remove the loader and turn on the Plug (press the button once) to enable current monitor and clear NOTIFICATION ALARM.This parameter value must be great than #4. If user set this parameter to default by Configure CC, the parameter #4 will be set to default value. Size: 1 Byte, Default Value: 13
Setting | Description |
---|---|
1 - 16 | Ampere |
This parameter defines maximum current, if the current plug provide to load is great than this parameter, the plug will light yellow LED, but plug cannot cutoff power.This parameter value must be less than parameter #3. If user set this parameter to default by Configure CC, the parameter #3 will be set to default value. Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
1 - 3 | Ampere |
This parameter defines the LED indication Function ON/OFF. This parameter can be configured with 0 or 1, where 0 means disable LED indication Function and will always be turnoff, and 1 means enable LED Function. Size: 1 Byte, Default Value: 1
Setting | Description |
---|
This parameter defines by how much current changed must change to be reported to the ZWave Controller or ZWave Gateway, in percents. If the rate of current change ratio is greater than this parameter, the plug will report the results, voltage, current, power and energy, that plug measure to ZWave Controller or ZWave Gateway. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 100 | % |
This parameter defined the relay status if remember or not. If remembered, the plug will restore the relay status last power off when the plug supply power next time. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Dont Remember, the relay will keep OFF when Plug Supply Power |
1 | emember the Relay Status. |
This parameter defines the timer function Enable/Disable. This parameter can be configured with 0 or 1, where 0 means disable time switch function and 1 enable. The time period will be defined in parameter #9.If this parameter is Set to 1, and when turn the plug relay on, the timer in plug start run with time period defined in parameter #9 and the plug will turn the relay off. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Time switch Disable |
1 | Time switch Enable |
This parameter defines the time period that plug time switch off. This parameter can be configured 1 ~ 65535(in minutes). If Parameter #9 is set to 1, and relay is turnon, the relay will be turnoff after delay this parameter. Size: 2 Byte, Default Value: 150
Setting | Description |
---|---|
1 - 65535 | minutes |
Hardware Platform | ZM5202 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 65 FW: 3.70 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-17085749 |
Z-Wave Product Id | 0x0266.0x0003.0x0350 |
Supported Meter Type | Electric Energy |
Supported Notification Types | Power Management |
Color | White |
Firmware Updatable | Updatable by Manufacturer |
Switch Type | Push Button |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |