This is a
Push the pairing button until the beep sounds three times.If you hold the master key over the card reader, you will be in Inclusion / Exclusion mode.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
GSL-01ZW can lock/unlock the deadbolt bynumeric keypad, the smartphone and IC card equipped with NFC and FeliCa. Also it can trigger home appliance actions such as lighting, TV, air conditioner. In conjunction with locking / unlocking through Glamo's "iRemocon" smart gateway, and also supports remote locking, deadbolt state reporting, and issuing time-based PIN code.Wireless communication with the device is encrypted, anti-forgery NFC key-card are used as its master key, and also tough metal housing is adopted. When trying to unlock "GSL-01ZW(L)" forcedly or when overyly high temperature due to fire is detected, an alert will be raised.Since "GSL-01ZW(L)" is connected with cloud side Glamo key management system, and is capable of insert, remove key data based on the system requests. It can be integrated with the existing property management enterprise and automated thus its system management cost can be greatly reduced.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Press the clear button and pairing button until the beep sounds three times.When you hold the master key over the card reader, the setting of Z - Wave Reset is reset.NOTE: Reset should be used only when the primary controller is missing or inoperable.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Z-Wave Plus Lifeline |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Get the status of Lock. It is read-only and can not be changed.mode 0-2bit000: Normal mode001: Pairing mode 010: Master key registration mode 011: Key registration mode 100: Door opening modealarm 3-5bit000: Alarm pattern 1001: Alarm pattern 2010: Alarm pattern 3011: Fire occurred100: I forcibly unlocked and tried to destroy101: Door open condition warning / 111: No alarmMalfunction 6bit0: No failure 1: Faulty Size: 1 Byte, Default Value: 56
Setting | Description |
---|---|
0 - 4 | mode (0-2bit) |
0 - 1 | malfunction (6bit) |
0 - 5 | alarm (3-5bit) |
Get key operation logs. It is read-only and can not be changed.300 logs can be saved. 1-2byte(unsigned value )Log output date and time Year3byte(unsigned value )Log output date and time Month4byte(unsigned value )Log output date and time Day Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - 65535 | Log output date and time Year |
1 - 12 | Log output date and time Month |
1 - 31 | Log output date and time Day |
1byte(unsigned value )Log output date and time Hour UTC2byte(unsigned value )Log output date and time Minute UTC3byte(unsigned value )Log output date and time Second UTC4byte(unsigned value )Event Type 0x01: Unlock 0x02: locking 0x03: alarm 0x04: Master Key Registration 0x05: Key registration 0x06: Delete master key 0x07: Delete key 0x08: Delete all keys 0x09: Key invalid 0x0A: Key change 0x0B: Pairing 0x0C: Default configuration 0x0D: Configuration 0x0E: Unlock without authentication 0x0F: Lock without authentication 0x10: Version up of the farm Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - 23 | Log output date and time Hour UTC |
0 - 59 | Log output date and time Minute UTC |
0 - 59 | Log output date and time Second UTC |
1 - 16 | Event Type |
1-4byte(unsigned value )event information0x01: UnlockKey ID 2byteresult 1byte0x00 success0x01 Failure0x02 Failure (in case the dead bolt did not move despite locking / unlocking operation in automatic mode)0x03 Failure (when clutch did not move in manual mode)0x02: lockingKey ID 2byteresult 1byte0x00 success0x01 Failure0x02 Failure (in case the dead bolt did not move despite locking / unlocking operation in automatic mode)0x03 Failure (when clutch did not move in manual mode)0x03: alarmAlarm type 1byte0x01 Alarm notification pattern10x02 Alarm notification pattern20x03 Alarm notification pattern30x04 Automatic unlock when fire occurs0x05 Destruction warning0x07 Alarm stop0x08 Battery remaining warning0x04: Master Key RegistrationKey ID 2byte0x05: Key registrationKey ID 2byte0x06: Delete master keyKey ID 2byte0x07: Delete keyKey ID 2byte0x08: Delete all keysNo details0x09: Key invalidKey ID 2byte0x0A: Key changeKey ID 2byte0x0B: Pairingresult 1byte0x00 Pairing success0x01 Pairing release successful0x0C: Default configurationNo details0x0D: ConfigurationSetting type 1byte (Refer to main unit setting)Setting contents 2byte0x0E: Unlock without authenticationNo details0x0F: Lock without authenticationNo details0x10: Version up of the farmVersion 1byteRevision 1byte Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - -1 | event information |
Get key data. It is read-only and can not be changed.500 key data can be saved.1byte(unsigned value )Valid flag 0bit Disabled1 Valid (default value)Authentication method 1-4bit0000 NFC0001 FeliCa0010 Android(HCE)0011 PIN1111 Default valueType 5-7bit000 Master key registration PIN key (one time) 001 Management PIN key010 Master key011 No locking / unlocking master key100 Additional key111 Default value2byte(unsigned value )Registration type 1byte0x00 user registration0x01 System registration0xFF Default value3-4byte(unsigned value )Number of effective unlocking times 2byte0xFF Default value Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - 7 | Type (byte-1 5-7bit) |
0 - 301 | Number of effective unlocking times 2byte |
0 - 1 | Valid flag (byte-1 0bit) |
0 - 15 | Authentication method (byte-1 1-4bit) |
0 - 256 | Registration type (byte-2 1byte) |
Key DATA 4byte(unsigned value )First byte to fourth byte Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - -1 | Key DATA(1-4) |
Key DATA 4byte(unsigned value )From the fifth byte to the eighth byte Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - -1 | Key DATA(9-12) |
0 - -1 | Key DATA(5-8) |
Key DATA 4byte(unsigned value )From the ninth byte to the twelfth byte Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - -1 | Key DATA(9-12) |
Key DATA 4byte(unsigned value )From the 13th byte to the 16th byte Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - -1 | Key DATA(13-16) |
Token 4byte(unsigned value )First byte to fourth byte Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - -1 | Log Index Flag(225-256) |
0 - -1 | Token(1-4) |
Token 4byte(unsigned value )From the fifth byte to the eighth byte Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - -1 | Token(5-8) |
Token 4byte(unsigned value )From the ninth byte to the twelfth byte Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - -1 | Token(9-12) |
Token 4byte(unsigned value )From the 13th byte to the 16th byte Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - -1 | Token(13-16) |
1-2byte(unsigned value )Registered Date Year3byte(unsigned value )Registered Date Month4byte(unsigned value )Registered Date Day Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - 65535 | Registered Date Year |
1 - 12 | Registered Date Month |
1 - 31 | Registered Date Day |
1byte(unsigned value )Registered Date Hour UTC2byte(unsigned value )Registered Date Minute UTC3byte(unsigned value )Registered Date Second UTC4byte(unsigned value )Reserved Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
1 - 59 | Registered Date Minute UTC |
1 - 23 | Registered Date Hour UTC |
1 - 59 | Registered Date Second UTC |
0 - -1 | Reserved |
1-2byte(unsigned value )Effective start date and time Year3byte(unsigned value )Effective start date and time Month4byte(unsigned value )Effective start date and time Day Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - 65535 | Effective start date and time Year |
1 - 12 | Effective start date and time Month |
1 - 31 | Effective start date and time Day |
1byte(unsigned value )Effective start date and time Hour UTC2byte(unsigned value )Effective start date and time Minute UTC3byte(unsigned value )Effective start date and timeSecond UTC4byte(unsigned value )Reserved2 Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - 23 | Effective start date and time Hour UTC |
0 - 59 | Effective start date and time Minute UTC |
0 - 59 | Effective start date and timeSecond UTC |
0 - -1 | Reserved2 |
1-2byte(unsigned value )Valid end date and time Year3byte(unsigned value )Valid end date and time Month4byte(unsigned value )Valid end date and time Day Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - 65535 | Valid end date and time Year |
1 - 12 | Valid end date and time Month |
1 - 31 | Valid end date and time Day |
1byte(unsigned value )Valid end date and time Hour UTC2byte(unsigned value )Valid end date and time Minute UTC3byte(unsigned value )Valid end date and time Second UTC4byte(unsigned value )Empty(0x00) Size: 4 Byte, Default Value: -256
Setting | Description |
---|---|
0 - 23 | Valid end date and time Hour UTC |
0 - 59 | Valid end date and time Minute UTC |
0 - 59 | Valid end date and time Second UTC |
Delete key data other than master key data.0: Default value1: Delete execution2: Delete complete3: Delete error4: time out Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 4 | Delete Flag |
1byteAlarm number 1byte0x01: Default value0x01: pattern0x02: pattern0x03: pattern2-3byteRing time 2byte0x001E: Default value0x0001-0x0E10: Setting range4byteReject reason / Release result 1byte0x00: Unlock successful0x01: Invalid key ID0x02: Invalid key data0x03: Incorrect combination of key ID and key data0x09: Key ID, key data not specified (default value) u00220xFE: time out0xFF: Key ID, initial value with key data specification Size: 4 Byte, Default Value: 16785151
Setting | Description |
---|---|
1 - 3 | Alerm Pattern |
1 - 3600 | Duration |
0 - 128 | Reason |
1-2byteKey ID3-4byteEmpty (0 fill) Size: 4 Byte, Default Value: -65536
Setting | Description |
---|---|
0 - 65535 | Key ID |
Key DATA 4byte(unsigned value )First byte to fourth byte Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - -1 | Key DATA(1-4) |
Key DATA 4byte(unsigned value )From the fifth byte to the eighth byte Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - -1 | Key DATA(5-8) |
Key DATA 4byte(unsigned value )From the ninth byte to the twelfth byte Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - -1 | Key DATA(9-12) |
Key DATA 4byte(unsigned value )From the 13th byte to the 16th byte Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - -1 | Key DATA(13-16) |
The items that can be set are as follows.1byteBuzzer sound 0-2bitrange action mode 3-4bit00 auto mode01 Manual mode10 Inoperative modeType setting that can be registered as a master key 5-6bit00 NFC card for master key only01 PIN number only10 NFC card for master key and PIN only11 Felica etc. All keys2byteBattery remaining warning threshold 1byterange 33-603byteImaginary mode0bit0:OFF / 1:ONauto lock 1bit0:OFF / 1:ONAutomatic unlock when fire occurs 2bit0:OFF / 1:ONPresence / absence of authentication at locking 3bit0:OFF / 1:ONUnreasonable unlock warning 4bit0:OFF / 1:ONTampering prevention function 5bit0:OFF / 1:ONAutomatic re-lock 6bit0:OFF / 1:ONPIN security key issuance setting on key body operation 7bit0:OFF / 1:ON4byteOpen arbitrarily 1bit0:OFF / 1:ONWakeup button 2bit0:OFF / 1:ON Size: 4 Byte, Default Value: 254871558
Setting | Description |
---|---|
0 - 7 | Buzzer volume (0-2bit) |
0 - 2 | action mode (3-4bit) |
0 - 3 | Type setting that can be registered as a master key (5-6bit) |
33 - 60 | Battery remaining warning threshold (1byte) |
0 - 1 | Imaginary mode (byte-3 0bit) |
0 - 1 | auto lock (byte-3 1bit) |
0 - 1 | Automatic unlock when fire occurs (byte-3 2bit) |
0 - 1 | Presence / absence of authentication at locking (byte-3 3bit) |
0 - 1 | Unreasonable unlock warning (byte-3 4bit) |
0 - 1 | Tampering prevention function (byte-3 5bit) |
0 - 1 | Automatic re-lock (byte-3 6bit) |
0 - 1 | PIN security key issuance setting on key body operation (7bit) |
0 - 1 | Open arbitrarily (byte-4 1bit) |
0 - 1 | Wakeup button (byte-4 2bit) |
1-2byteMaximum Number of Key Registrations 2byterange 1-5003-4byteMaximum number of key registrations by users 2byterange 1-500 Size: 4 Byte, Default Value: 335546880
Setting | Description |
---|---|
1 - 500 | Maximum number of key registrations by users(byte-7,8 2byte |
1 - 500 | Maximum Number of Key Registrations (byte-5,6 2byte) |
Key DATA 4byte(unsigned value )First byte to fourth byte Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - -1 | Key DATA(1-4) |
Key DATA 4byte(unsigned value )From the fifth byte to the eighth byte Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - -1 | Key DATA(5-8) |
Key DATA 4byte(unsigned value )From the 13th byte to the 16th byte Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - -1 | Key DATA(13-16) |
Set lock operation information.1bytemode 1byte0x00:Unlock0x01: locking0x02: Key registration modeUnlock: Default value2-3byteKey ID 2byte0xFF: Default value4byteEmpty (0 fill) Size: 4 Byte, Default Value: -256
Setting | Description |
---|---|
0 - 2 | mode |
0 - 500 | Key ID |
The index where the log is saved is 1, the index which is not saved is 0, and it is possible to check the existence with the bit flag. It is read-only and can not be changed.Range:index1-index32(unsigned value ) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - -1 | Log Index Flag(1-32) |
Range:index33-index64(unsigned value ) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - -1 | Log Index Flag(33-64) |
Range:index65-index96(unsigned value ) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - -1 | Log Index Flag(65-96) |
Range:index97-index128(unsigned value ) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - -1 | Log Index Flag(97-128) |
Range:index129-index160(unsigned value ) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - -1 | Log Index Flag(129-160) |
Range:index161-index192(unsigned value ) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - -1 | Log Index Flag(161-192) |
Range:index193-index224(unsigned value ) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - -1 | Log Index Flag(193-224) |
Range:index257-index288(unsigned value ) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - -1 | Log Index Flag(257-288) |
Range:index289-index300(unsigned value ) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - -1048576 | Log Index Flag(289-300) |
Key DATA 4byte(unsigned value )First byte to fourth byte Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - -1 | Key DATA(1-4) |
Key DATA 4byte(unsigned value )From the fifth byte to the eighth byte Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - -1 | Key DATA(5-8) |
Key DATA 4byte(unsigned value )From the ninth byte to the twelfth byte Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - -1 | Key DATA(9-12) |
Key DATA 4byte(unsigned value )From the 13th byte to the 16th byte Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - -1 | Key DATA(13-16) |
Token 4byte(unsigned value )First byte to fourth byte Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - -1 | Token (1-4) |
Token 4byte(unsigned value )From the fifth byte to the eighth byte Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 | Token (5-8) |
Token 4byte(unsigned value )From the ninth byte to the twelfth byte Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - -1 | Token (9-12) |
Token 4byte(unsigned value )From the 13th byte to the 16th byte Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - -1 | Token (13-16) |
1-2byte(unsigned value )Registered Date Year3byte(unsigned value )Registered Date Month4byte(unsigned value )Registered Date Day Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - 65535 | Registered Date Year |
1 - 12 | Registered Date Month |
0 - 31 | Registered Date Day |
1byte(unsigned value )Registered Date Hour UTC2byte(unsigned value )Registered Date Minute UTC3byte(unsigned value )Registered Date Second UTC4byte(unsigned value )Reserved Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - 23 | Registered Date Hour UTC |
0 - 59 | Registered Date Minute UTC |
0 - 59 | Registered Date Second UTC |
0 - 255 | Reserved |
1-2byte(unsigned value )Effective start date and time Year3byte(unsigned value )Effective start date and time Month4byte(unsigned value )Effective start date and time Day Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - 65535 | Effective start date and time Year |
1 - 31 | Effective start date and time Day |
1 - 12 | Effective start date and time Month |
1byte(unsigned value )Effective start date and time Hour UTC2byte(unsigned value )Effective start date and time Minute UTC3byte(unsigned value )Effective start date and timeSecond UTC4byte(unsigned value )Reserved2 Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - 23 | Effective start date and time Hour UTC |
0 - 59 | Effective start date and time Minute UTC |
0 - 59 | Effective start date and timeSecond UTC |
0 - 255 | Reserved2 |
1-2byte(unsigned value )Valid end date and time Year3byte(unsigned value )Valid end date and time Month4byte(unsigned value )Valid end date and time Day Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - 65535 | Valid end date and time Year |
1 - 12 | Valid end date and time Month |
1 - 31 | Valid end date and time Day |
1byte(unsigned value )Valid end date and time Hour UTC2byte(unsigned value )Valid end date and time Minute UTC3byte(unsigned value )Valid end date and time Second UTC4byte(unsigned value )Empty(0x00) Size: 4 Byte, Default Value: -256
Setting | Description |
---|---|
0 - 23 | Valid end date and time Hour UTC |
0 - 59 | Valid end date and time Minute UTC |
0 - 59 | Valid end date and time Second UTC |
1byte(unsigned value )action 1byte0x00 Registration0x01 update0x02 Delete0xFF Default value2-3byteKey ID 2byte(unsigned value )0xFF Default value4byte(unsigned value )Reject reason 1byte0x01 success0xFD Failure0xFE time out0xFF Default value Size: 4 Byte, Default Value: -1
Setting | Description |
---|---|
0 - 255 | action |
0 - 65535 | Key ID |
0 - 255 | Reject reason |
The ID for which key data is registered is 1, the ID which is not registered is 0, and the presence or absence can be confirmed by bit flag. It is read-only and can not be changed.Range:ID1-ID32(unsigned value ) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - -1 | KeyID Flag(1-32) |
Range:ID33-ID64(unsigned value ) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - -1 | KeyID Flag(33-64) |
Range:ID65-ID96(unsigned value ) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - -1 | KeyID Flag(65-96) |
Range:ID97-ID128(unsigned value ) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - -1 | KeyID Flag(97-128) |
Range:ID129-ID160(unsigned value ) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Valid flag (byte-1 0bit) |
0 - 15 | Authentication method (byte-1 1-4bit) |
0 - 7 | Type (byte-1 5-7bit) |
0 - 256 | Registration type (byte-2 1byte) |
0 - 301 | Number of effective unlocking times 2byte |
0 - -1 | KeyID Flag(129-160) |
Range:ID161-ID192(unsigned value ) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - -1 | KeyID Flag(161-192) |
Range:ID193-ID224(unsigned value ) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - -1 | KeyID Flag(193-224) |
Range:ID225-ID256(unsigned value ) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - -1 | KeyID Flag(225-256) |
Range:ID257-ID288(unsigned value ) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - -1 | KeyID Flag(257-288) |
Range:ID289-ID320(unsigned value ) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - -1 | KeyID Flag(289-320) |
Range:ID321-ID352(unsigned value ) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - -1 | KeyID Flag(321-352) |
Range:ID353-ID384(unsigned value ) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - -1 | KeyID Flag(353-384) |
Range:ID385-ID416(unsigned value ) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - -1 | KeyID Flag(385-416) |
Range:ID417-ID448(unsigned value ) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - -1 | KeyID Flag(417-448) |
Range:ID449-ID480(unsigned value ) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - -1 | KeyID Flag(449-480) |
Range:ID481-ID500(unsigned value ) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - -61696 | KeyID Flag(481-500) |
Delete all saved logs.0: Default value1: Delete execution2: Delete complete3: Delete error4: time out Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 4 | Delete flag |
Hardware Platform | ZM5202 |
Device Type | Door Lock - Keypad |
Network Operation | Listening Sleeping Slave |
Firmware Version | HW: 1 FW: 1.03:01.03 |
Z-Wave Version | 6.71.01 |
Certification ID | ZC10-17125904 |
Z-Wave Product Id | 0x0348.0x0003.0x0001 |
Firmware Updatable | Updatable by Consumer via Internet |
Supported Notification Types | Access ControlEmergency AlarmSystem |
Door Lock Type | Deadbolt Motor Attachment |
Security V2 | S2_ACCESS_CONTROL |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |