Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Simon iO Dimmer is ready to operate with Z-Wave controllers and configured to be managed by Simon100 IO APP using the HUB plug IO for getting a better user experience. Sending the Blind Up/Down or setting a specific position.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
When the pushbutton is released after a press of (30sec
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 3 | Z-Wave Plus Lifeline |
2 | 20 | ctrl.CC Basic, Basic Report, Value 0x00 - 0x63 Report Dimming vaule after 2 seconds of last dimming change. |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Activates the Central LED. Configuration Used by Masters iO in order to identify the devices associated to their Group2 during manual association process. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Turns the LED OFF |
1 - 255 | Turns the LED ON |
Time that Dimmer delays the activation of the load after it receives an ON request.This value must be set in hexadecimal format, and can accept these values:0 --> ON Delay is 0.0x01...0x7F --> Delay ON is from 1 to 127 seconds. (1 second resolution)0x80...0xfE--> Delay ON is from 1 to 127 seconds. (1 minute resolution) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | ON Delay is 0 seconds |
1 - 127 | ON Delay is set in seconds from 1 to 127 seconds |
128 - 254 | ON Delay is set in minutes from 1 to 127 minutes |
Time that Dimmer activates of the load after it turns the load ON.This value must be set in hexadecimal format, and can accept these values:0 --> Activation Time is 0.0x01...0x7F --> Activation Time is from 1 to 127 seconds. (1 second resolution)0x80...0xfE--> Activation Time is from 1 to 127 seconds. (1 minute resolution) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Activation Time is 0 seconds |
1 - 127 | Activation Time is set in seconds from 1 to 127 seconds |
128 - 154 | Activation Time is set in minutes from 1 to 127 minutes |
Sets the Left and Right Leds to 20% in order to find the device and the touch areas at night. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Left and Right LEDs OFF |
1 - 255 | Left and Right LEDs ON at 20percent |
Locks the local control of the sunblind. This configuration does not modifies the control via Z-Wave. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Local action enabled |
1 - 255 | Local action locked |
Write only parameter used to restore configurations or perform a completely restore default. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
17170 | Configuration values are restored |
39015 | Factory reset. |
Time that Dimmer delays the deactivation of the load after it receives an OFF request.This value must be set in hexadecimal format, and can accept these values:0 --> Delay OFF is 0.0x01...0x7F --> Delay OFF is from 1 to 127 seconds. (1 second resolution)0x80...0xfE--> Delay OFF is from 1 to 127 seconds. (1 minute resolution) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | OFF Delay is 0 seconds |
1 - 127 | OFF Delay |
128 - 254 | OFF Delay is set in minutes from 1 to 127 minutes |
Defines the action to be performed when key is pressed. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 | When short press, the device toggles the load. The Slider does not work. |
1 | When short press, the device turns ON the load. The Slider does not work. |
2 | When short press, the device turns OFF the load. The Slider does not works. |
4 | When short press, the device turns ON the load. When hold press from 2seconds to 10seconds device turns OFF the load. The Slider does not works with this configuration, the device will not send the Node Info neither Show the LEDs feedback with this press action. The Slider does not work. |
5 | When short press, the device toggles the load. The Slider dims the load when it is ON. |
Write only value that performs a fast blink on Central LED during 5 seconds in order to identify the device when it is installed in a multiple frame. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 255 | Central LED performs a fast blink |
Read only 2 Byte configuration parameter used to read the dimmer state.Byte 0 is used to know the load state ON or OFF.0 Dimmer is OFF.1 Dimmer is ON.Byte 1 is used to Know the last active dimming percentage. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 99 | Load is OFF and las timming value is from 1% to 99% |
256 - 355 | Load is ON Dimmed at 1% to 99% |
Read only configuration used to know is device needs to be calibrated in order to work properly. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Device is calibrated |
255 | Calibration must be performed |
Locks the major part of Hold press effects in order to avoid undesired callibrations, Z-Wave changes or restores Default.0xFF Hold Press from 2sec to 20 sec does not performs a Node infoHold Press of 10 to 15 does not performs a automatic callibrationHold press of 15 to 30 does not changes the sunblind or awing reportsHold press of 30sec restores configuration except Lock Hold Press, and sends a Node info in order to add or remove from Z-Wave Network Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Hold Press is available |
1 - 255 | Hold Press from 2sec to 20 sec does not performs a Node info,Hold Press of 10 to 15 does not performs a automatic callibration,Hold press of 15 to 30 does not changes the sunblind or awing changes, Hold press of 30sec restores configuration except Lock Hold Press, and sends a Node info in order to add or remove from Z-Wave Network |
Sets the u0022Set Timeu0022 that will take the Dimmer to go from 0% to 100%This value must be set in hexadecimal format, and can accept these values:0 --> Set Time is 0.0x01...0x7F --> Set Time is from 1 to 127 seconds. (1 second resolution)0x80...0xfE--> Set Time is from 1 to 127 seconds. (1 minute resolution) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Sets Time is 0 |
1 - 127 | Set Time is set in seconds from 1 to 127 minutes |
128 - 254 | Set Time is set in minutes from 1 to 127 minutes |
Sets the u0022Fade Timeu0022 that will take the Dimmer to go from 100% to 0%This value must be set in hexadecimal format, and can accept these values:0 --> Fade Time is 0.0x01...0x7F --> Fade Time is from 1 to 127 seconds. (1 second resolution)0x80...0xfE--> Fade Time is from 1 to 127 seconds. (1 minute resolution) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Fade Time is 0 seconds |
1 - 127 | Fade Time is set in seconds from 1 to 127 seconds |
128 - 254 | Fade Time is set in minutes from 1 to 127 minutes |
Relative adjust used to set the minimum regulation value. This adjust is done in reference to internal values, accepted dimming values will always be from 1 to 0x63.Minimum Value must be < than Maximum Value. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 98 | minimum internal dimming value |
Relative adjust used to set the maximum regulation value. This adjust is done in reference to internal values, accepted dimming values will always be from 1 to 0x63.Maximum Value must be > then Minimum Value. Size: 1 Byte, Default Value: 100
Setting | Description |
---|---|
2 - 99 | maximum internal dimming value |
Write only configuration used to request the automatic adjust of UP and DOWN times. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
255 | Sunblind starts its callibration process |
Hardware Platform | ZM5202 |
Device Type | Light Dimmer Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 4.24:78.59:70.48 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-18026010 |
Z-Wave Product Id | 0x0267.0x0007.0x0000 |
Neutral Wire Required | ok |
Supported Meter Type | |
Electric Load Type | |
Firmware Updatable | |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |