This is a
When the pushbutton is released after a press of (2sec
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Roller Blind IO is ready to operate with Z-Wave controllers and configured to be managed by Simon100 IO APP using the HUB plug IO for getting a better user experience. Sending the Blind Up/Down or setting a specific position.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
When the pushbutton is released after a press of (30sec
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 3 | Z-Wave Plus Lifeline |
2 | 20 | ctrl.CC Basic, Basic Report, Value 0x00 - 0x63 Report sunblind position when the value changes and it is stopped |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Activates the Central LED. Configuration Used by Masters iO in order to identify the devices associated to their Group2 during manual association process. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Turns the LED OFF |
1 - 255 | Turns the LED ON |
Sets the Left and Right Leds to 20% in order to find the device and the touch areas at night. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Left and Right LEDs OFF |
1 - 255 | Left and Right LEDs ON at 20percent |
Locks the local control of the sunblind. This configuration does not modifies the control via Z-Wave. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Local action enabled |
1 - 255 | Local action locked |
Write only parameter used to restore configurations or perform a completely restore default. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
17170 | Configuration values are restored |
39015 | Factory reset. |
Write only value that performs a fast blink on Central LED during 5 seconds in order to identify the device when it is installed in a multiple frame. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 255 | Central LED performs a fast blink |
Read only value used to inform about sunblind state.Byte 0 is used to inform if Sunblind is stopped or going UP or DOWNByte 2 is used to report the sunblind position. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 99 | Sunblind is stoped with position 0 to 99per cent |
256 - 355 | Sunblind is Moving DOWN with position 0 to 99per cent |
512 - 611 | Sunblind is Moving UP with position 0 to 99per cent |
Read only Value that informs that UP/DOWN times have not been adjusted and position percentage will not be adequate. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Calibration is not required. |
255 | It is necessary to calibrate the device to work properly. |
Locks the major part of Hold press effects in order to avoid undesired callibrations, Z-Wave changes or restores Default.0xFF Hold Press from 2sec to 20 sec does not performs a Node infoHold Press of 10 to 15 does not performs a automatic callibrationHold press of 15 to 30 does not changes the sunblind or awing reportsHold press of 30sec restores configuration except Lock Hold Press, and sends a Node info in order to add or remove from Z-Wave Network Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Hold Press is available |
1 - 255 | Hold Press from 2sec to 20 sec does not performs a Node info,Hold Press of 10 to 15 does not performs a automatic callibration,Hold press of 15 to 30 does not changes the sunblind or awing changes, Hold press of 30sec restores configuration except Lock Hold Press, and sends a Node info in order to add or remove from Z-Wave Network |
Sets the UP time In seconds in order to calculate the sunblind position. Size: 1 Byte, Default Value: 60
Setting | Description |
---|---|
1 - 120 | Sets UP time of Sunblind |
Sets the DOWN time In seconds in order to calculate the sunblind position. Size: 1 Byte, Default Value: 60
Setting | Description |
---|---|
1 - 120 | Sets DOWN time of Sunblind |
Write only configuration used to request the automatic adjust of UP and DOWN times. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
255 | Sunblind starts its callibration process |
Hardware Platform | ZM5202 |
Device Type | Window Covering - Pos/End Aware |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 4.24:75.53:66.47 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-18026011 |
Z-Wave Product Id | 0x0267.0x0004.0x0000 |
Neutral Wire Required | ok |
Window Covering Control Features | Automatic Calibration |
Firmware Updatable | Updatable by Professional/Technician |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |