This is a
When the pushbutton is released after a press of (2sec
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Master Dimmer iO is ready to operate with Z-Wave controllers and configured to be managed by Simon100 iO APP using the HUB plug iO for getting a better user experience. allowing the control of other Z-Wave devices via Basic Set/Get commands.Available colors Black and White.visit http://www.simon.es/simon100/ to learn more about Simon 100 iO.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
When the pushbutton is released after a press of (30sec
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 3 | Z-Wave Plus Lifeline |
2 | 20 | ctrl. This group is used to add the devices to be controlled by Master Roller blind. Device sends Basic Sets and Gets, and Manufacturer specific Gets, Configuration Gets and Sets when manual association is being performed over Simon devices. |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Activates the Central LED. Configuration Used by Masters iO in order to identify the devices associated to their Group2 during manual association process. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Turns Central LED OFF |
1 - 255 | Turns Central LED ON |
Sets the Central LED to 20% in order to find the device at night. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Central LED OFF |
1 - 255 | Central LED ON at 20percent |
Locks the local control of associated devices and controller. This configuration does not modifies the control via Z-Wave, where if a Set is received it will retransmitted to all group 2 associated nodes Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Local control is available |
1 - 255 | Local control is locked |
Write only parameter used to restore configurations or perform a completely restore default. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
17170 | Configuration values are restored |
39015 | Factory reset |
Enables or disables the manual association process. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Hold press of 10sec to 30sec starts manual association of devices to group 2 |
1 - 255 | Hold press of 10sec to 30sec sends a Node Info |
Defines the function performed by the device when keypad is pressed Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 | Short press switches between the last power on and off (depending on the status of the associated control) by sending a Basic Set to 0x00 or 0xFF to the associated nodes. |
1 | Short press activates those associated by sending Basic Set to 0xFF |
2 | Short press deactivates those associated by sending Basic Set to 0x00 |
4 | Short Press always turn on the associated nodes by sending a Basic Set to 0xFF. Press from 2sec to 10sec always turns off the associated nodes by sending a Basic Set to 0x00 |
5 | When Short press Master inverts the load state via Basic Set, When the slider is enabled and load is ON, Multilevel Sets are sent to modify the dimming value. |
Write only value that performs a fast blink on Central LED during 5 seconds in order to identify the device when it is installed in a multiple frame Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 255 | Central LED performs a fast blink |
Configuration used to know the device state and last active dimming value in case of act retransmitting values different from 0 or 0xFF. This value is represented in Hexadecimal. Byte 0 informs about Load State (0 load is OFF and 1 load is ON) Byte 1 informs about Last active load value (0-0x63 or 0xFF) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 99 | Load is OFF or sunblind is stopped with diming value or position x |
256 - 355 | Load is ON or sunblind is going DOWN with diming value or position x |
Locks the major part of Hold press effects in order to avoid undesired Z-Wave changes, associations or restores Default. 0xFF Hold Press from 2sec to 10 sec does not performs a Node info. Hold Press of 10 to 30 does not performs a manual association process. Hold press of 30sec restores configuration except Lock Hold Press, and sends a Node info in order to add or remove from Z-Wave Network Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Hold press is available |
1 - 255 | Hold Press is Locked |
This configuration has only effects when there is only 1 associated node in group 2. Is used to set if Master has to be always informed about the controlled device state or it is consulted when user touches the keypad. Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 | Device must receive reports about controlled device state |
1 - 255 | Device consults the device state once keypad detects touch |
Disables the sending of Central Scene Notifications to avoid perform 2 actions at same time (Central Scene action and Group 2 action). Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 | Device does not sends Central Scene Notifications |
1 - 255 | Device sends Central Scene Notifications is no devices are added to group 2 |
Hardware Platform | ZM5202 |
Device Type | Wall Controller |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 4.24:79.50 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-18026013 |
Z-Wave Product Id | 0x0267.0x0008.0x0000 |
Neutral Wire Required | ok |
Firmware Updatable | Updatable by Professional/Technician |
Z-Wave Scene Type | Central Scene |
Frequency | XXfrequency |