1Refer to your primary controller to enter into the Inclusion Mode or Exclusion Mode2When it is prompted to enter it, please triple click the PROG button within 1 second.Green Indicator flashes TWICE then stay off
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
ZXT-600 AC Master is a Z-Wave plus certified IR Bridge for split air conditioner control by receiving Z-Wave command and translating to Infrared command and flawlessly work with any Z-Wave compliant gateway. With its over 250 brands built-in code library and ever-green up to date cloud IR database supporting advanced code learning search, ZXT-600 can easily set up and smart control most of AC brands and models actively worldwide by Z-Wave gateway. The battery powered device will allow you to mount it anywhere you want such as wall, ceiling or put it on table and never compromise on the form factor. By supporting OTA function, gateway can enable ZXT-600 to update firmware if newest available.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Press and Hold PROG button for 3 seconds on AC Master, the Green Indicator will light up. DO NOT Release the PROG Button until Green Indicator flashes TWICE.Remark : All the Setting and Data will be permanently deleted.Please use this procedure only when the network primary controller is missing or otherwise inoperable.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Association Group #1 (max. 1 node) is default to associate with the primary controller (Gateway/Hub/Controller) for AC Master Status change report, refer to below for report details: a) Current Room Temperature (report in precision of 0.5C or 1F) (It will be according to Configuration Parameter 39 setting to decide the trigger level) b) Current Battery Level (Only apply in Low Battery Warning happened) c) Device Reset Locally Notification (Only report when the AC Master has been triggered the RESET TO DEFAULT) |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Default: 0x00range: (0x0000 to 0x20)refer to learning mapping table
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 32 | Storage Location |
Default: 0x00range: 0 to 4 (0x00 to 0x04)0(0x00) : Idle - IR Channel is idle1(0x01) : OK - the last learning operation was completed successfully2(0x02) : Learning - ZXT-600 is busy processing previous learning request3(0x03) : FullAll locations are being used.4(0x04) : The last learning request was failedNote:The status value 0x01 and 0x04 will be reset to 0x00 after ZXT-600 receives a get command to this parameter.
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 4 | IR Code Learning Status |
Refer to Code Finder Webpage
Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1150 | IR Code Number |
0(0x00) = Disable (Default)(for saving battery life)Auto report if room temperature is different from last report.1(0x01) = 1F (0.5C)2(0x02) = 2F (1C) 3(0x03) = 3F (1.5C)4(0x04) = 4F (2C)5(0x05) = 5F (2.5C)6(0x06) = 6F (3C)7(0x07) = 7F (3.5C)8(0x08) = 8F (4C)
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 8 | Room Temperature Change |
Default: 0xFF0 or 255(0x00 or 0xFF)0(0x00): Disable255(0xFF): Enable (Default)
Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 | Disable |
255 | Enable |
Default: 0x01Range 0 to 1 (0x00 or 0x01)0(0x00) : Swing OFF1(0x01) : Swing Auto (Default)
Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | SWING OFF |
1 | SWING Auto |
Auto report by the following time interval.1(0x01) = 1 Hr2(0x02) = 2 Hrs3(0x03) = 3 Hrs4(0x04) = 4 Hrs5(0x05) = 5 Hrs6(0x06) = 6 Hrs7(0x07) = 7 Hrs8(0x08) = 8 Hrs (Default)
Size: 1 Byte, Default Value: 8
Setting | Description |
---|---|
0 - 8 | Time Interval |
Temperature offset value.0(0x00) = 0C (Default)1(0x01) = 1C2(0x02) = 2C3(0x03) = 3C4(0x04) = 4C5(0x05) = 5C255(0xFF) = -1C254(0xFE) = -2C253(0xFD) = -3C252(0xFC) = -4C251(0xFB) = -5C
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 5 | Positive Range |
251 - 255 | Negative Range |
Hardware Platform | ZM5202 |
Device Type | Thermostat - HVAC |
Network Operation | Listening Sleeping Slave |
Firmware Version | HW: 3 FW: 1.03:01.07:171.06 |
Z-Wave Version | 6.61.00 |
Certification ID | ZC10-18036053 |
Z-Wave Product Id | 0x037C.0x0109.0x8490 |
Sensors | Target Temperature |
Color | White |
Thermostat HVAC Systems Supported | |
Thermostat Modes | AutoAwayCoolDry AirFan OnlyHeatResume |
Firmware Updatable | Updatable by Consumer by RF |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |