This is a
The sensor must be added to a Z-Wave network prior to use. To include the sensor in a network both the sensor and the network controller must be in inclusion mode at the same time. Refer to the instructions provided by the manufacturer of your specific controller for details on initiating the controllers inclusion mode. 1)Verify that the Z-Wave Plus controller you are using is compatible with the Flood Freeze sensor.2)Either mount or move the Flood Freeze sensor as close as possible to the location the sensor will remain. See installation section below.3)Put your Z-Wave Plus Controller into add (inclusion) mode. 4)To add the sensor to an existing Z-Wave network, follow the directions to put your Z-Wave Controller into add (inclusion) mode. The Flood Freeze enters add and remove (inclusion/exclusion) when powered on (when battery is added).If the LED starts blinking continuously, the sensor has no node ID and was not successfully added, so start step C over again.Make sure to remove the battery for 10 seconds if adding to a Z-Wave network fails.5)If after 5 seconds the LED is not blinking, look on the Z-Wave controllers interface for feedback on whether the sensor was added successfully. If you do not see any feedback that the sensor was added, follow directions for removing the sensor from a Z-Wave network, and then try adding the sensor again. If you are still having problems, you may need to add additional Z-Wave listening devices in-between the controller and the sensor.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Z-Wave Plus Wireless Flood/Freeze Sensor. Product Overview -Z-Wave Plus enabled device which detects flood and freeze. -Reports tamper condition when cover is open. Product Specifications -For indoor use only -Operating frequency: 868.2 MHz -Operating temperature: 049C, 32120F (ambient temperature) -Operating humidity 5-95% non-condensing -Battery type required: 3V Lithium CR123A -Battery life approximately 5 years
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
The Flood Freeze sensor factory defaults on network exclusion.Please use this procedure only when the network primary controller is missing or otherwise inoperable."- You may use wording of your own choosing as long as it effectively means the same thing
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In order to communicate with the device, a static controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time is significantly decreased.
This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbox. Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static controller this controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the device. To wakeup the device please perform the following action: This device is asleep most of the time but can respond to queries on a Wake Up Notification; however for test purposes, the device will stay awake while tampered for testing Z-Wave Plus command class functionality.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline |
Hardware Platform | ZM5202 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 255 FW: 10.09 |
Z-Wave Version | 6.51.09 |
Certification ID | ZC10-18056106 |
Z-Wave Product Id | 0x014A.0x0005.0x0010 |
Color | White |
Supported Notification Types | Water Alarm |
Sensors | FreezeOpen/Closed (Binary) |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |