This is a
Add for inclusion: a) Set the Z-Wave network main controller into adding mode.b) Power cycle once for the led bulb(OFF->ON).The led bulb will flash once when it has been include into the network.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
AIBASE RGBW Bulb is a switch multilevel device based on Z-Wave enhanced 232 slave libraryof V6.51.09.RGBW Bulb has 5 main color channels available for you to adjust: Warm white , Cold white,Red,Green and Blue. RGBW Bulb can be included and operated in any ZWave network with other ZWave certifieddevices from other manufacturers and/or other applications. All nonbattery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.The RGBW Bulb is a security Z-Wave device(S0), so a security enabled controller is needed for take full advantage of all functionally for the LED Bulb. It also supports the Over The Air (OTA) feature for the products firmware upgrade.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Reset the device :Led bulb re-power 6 times (between 0.5-2 seconds each time); If the 6th power on, the led bulb flashes twice (first time: red to green to blue gradient transition, second time: 2700K), which means that the resetting is successful.NOTE:Using this action in case of the primary controller is missing or inoperable.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Z-Wave Plus Lifeline1. When the state of the LED Bulb is changed, Sending Switch Multilevel Report to the associated nodes.2. Sending Device Reset Locally CC to the associated nodes. |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
It is used to get the internal temperture of the bulb. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-128 - 127 | It isused to get the internal temperture of the bulb. |
This parameter is used to Reset to factory configuration and remove the node from the Z-Wave network, or to Reset Configuration parameter to their default value. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
-2004318072 | Reset to factory configuration and removed the node from the Z-Wave network. |
-2013265920 | Reset Configuration parameter to default value. |
Hardware Platform | ZM5101 |
Device Type | Light Dimmer Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 0 FW: 2.00 |
Z-Wave Version | 6.51.09 |
Certification ID | ZC10-18056115 |
Z-Wave Product Id | 0x0384.0x0003.0x0003 |
Firmware Updatable | Updatable by Manufacturer |
Communications Protocol | Manufacturer Proprietary Protocol |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |