Dies ist ein
Ring Motion Sensor can be added via SmartStart or via classic inclusion mode SmartStart Inclusion Steps:1. Initiate add sensor flow in the Ring Alarm mobile applicationFollow the guided add flow instructions provided in the application2. Scan the QR code found on the package of the sensor or the QR code found on the back of the sensor3. Pull the battery tab on the sensor4. When the inclusion process in complete, the LED on the sensor will be solid blue, then go out.5. Test the sensor.Place the sensor in an unoccupied room. Leave the room for at least four minutes. Return to the room and pass in front of the sensorLED will flash if motion is detected.Classic Inclusion Steps:1. Initiate add sensor flow in the Ring Alarm mobile applicationFollow the guided add flow instructions provided in the application2. Select add manually and enter the 5 digit DSK pin found on the package of the sensor or the QR code found on the back of the sensor3. Pull the battery tab on the sensor4. When the inclusion process in complete, the LED on the sensor will be solid blue, then go out.5. Test the sensor.Place the sensor in an unoccupied room. Leave the room for at least four minutes. Return to the room and pass in front of the sensorLED will flash if motion is detected.
Z-Wave ist der internationale Funkstandard zur Kommunikation von Geräten im intelligenten Haus. Dies ist ein Z-Wave Gerät und nutzt die im Quickstart angegebene Funkfrequenz.
Dank Z-Wave können Produkte unterschiedlicher Hersteller miteinander in einem Funknetz verwendet werden. Damit ist auch dieses Produkt mit beliebigen anderen Produkten anderer Hersteller in einem gemeinsamen Z-Wave Funknetz einsetzbar.
Wenn ein Gerät die spezielle sichere Kommunikation unterstützt dann wird es immer dann mit einem anderen Gerät sicher kommunizieren, wenn dieses Gerät auch eine sichere Kommunikation unterstützt. Ansonsten wird aus Kompatibilitätsgründen auf einen normalen Kommunikation umgeschaltet.
Weitere Informationen wie Produktneugkeiten, Tutorials, Supportforen etc. erhalten Sie auf www.zwave.de.
The Ring Protect security system is Rings entry into the DIY security solution space intended to provide customers with a Ring-branded, unique and simplified home security system.Ring Protect features a Z-Wave passive infrared (PIR) motion detector which will be used as a primary intrusion detection unit in the system.The motion sensor will feature best-in-class width and depth of field detection, pet immunity and adjustable sensitivity.The motion sensor will be included in the professionally monitored alarm system.Additionally, the sensors functionality will be extended to the automation features of the Ring Protect solution.
Bitte lesen Sie die Benutzeranleitung bevor Sie das Gerät in Betrieb nehmen.
Damit ein Z-Wave zu einem neuen Netz hinzugefügt werden kann muss es sich im Auslieferungs- oder Reset-Zustand befinden. Im Zweifel ist es sinnvoll, eine Exklusion durchzuführen, um das Gerät ganz sicher in diesem Zustand zu bringen. Diese Exklusion kann von jedem beliebigen Z-Wave Controller durchgeführt werden.
Dieses Gerät kann auch ohne Hilfe eines Controller in den Reset-Zustand zurückgeführt werden. Dies sollte jedoch nur dann gemacht werden wenn der Primärcontroller des Z-Wave-Netzes nicht mehr verfügbar oder defekt ist.
Factory Default Instructions1.Using a pointed end of a paperclip, press and hold the reset button via the reset pin hole found at the back of the sensor2.Blue LED will start to blink rapidly3.Wait for the blue LED to stop blinkingUse this procedure only in the event that the network primary controller is missing or otherwise inoperable.
Im Auslieferungszustand ist das Gerät mit keinem Z-Wave-Netz verbunden. Damit es
mit anderen Z-Wave Geräten kommunizieren kann, muss es in ein bestehendes Z-Wave Netz
eingebunden werden. Dieser Prozess wird bei Z-Wave Inklusion genannt. Geräte können
Netzwerke auch wieder verlassen. Dieser Prozess heißt bei Z-Wave Exklusion. Beide
Prozesse werden von einem Controller gestartet, der dazu in einen Inklusion- bzw.
Exklusion-Modus geschaltet werden muss. Das Handbuch des Controllers enthält
Informationen, wie er in diese Modi zu schalten ist. Erst wenn der Controller
des Z-Wave Netzes im Inclusion-Modus ist, können Geräte hinzugefügt werden.
Das Verlassen des Netzes durch Exklusion führt zum Rücksetzen dieses Gerätes
in den Auslieferungszustand.3>
Das Gerät ist batteriegespeist und damit in der Regel in einem Tiefschlafmodus um
Strom zu sparen. Im Tiefschlafmodus kann das Gerät keine Funksignale empfangen. Daher
wird ein (statischer) Controller benötigt, der netzgespeist und damit immer
funkaktiv ist. Dieser Controller - zum Beispiel ein IP-Gateway - verwaltet eine
Nachrichten-Mailbox für dieses batteriegespeiste Gerät, in dem Nachrichten an dieses
Gerät zwischengespeichert werden. Ohne einen solchen statischen Controller wird die
Nutzung dieses batteriebetriebenen Gerätes sehr schnell zur Entladung der Batterie
führen oder die Nutzung ist komplett unmöglich. Dieses Gerät weckt regelmäßig auf, meldet dies durch Aussenden einer sogenannten
Wakeup-Notifikation und leert dann seine Mailbox im statischen Controller. Dafür
muss bei der Inclusion die Node-ID des Controllers und ein Aufweckinterval
definiert werden. Erfolgt die Inklusion durch einen statischen Controller
wie zum Beispiel ein IP-Gateway, wird dieser Controller diese Konfiguration
automatisch erledigen und in der Regel eine Nutzerschnittstelle anbieten, um das
Aufweck-Interval den Nutzerbedürfnissen anzupassen. Das Aufweckinterval ist ein
Kompromiss zwischen maximaler Batterielaufzeit und minimaler Reaktionszeit des
batteriegespeisten Gerätes. Um das Gerät manuell aufzuwecken, führen Sie die folgende Aktion durch:
Removing the top cover will put the sensor in tamper mode and will keep the sensor awake Inklusion
Ring Motion Sensor can be added via SmartStart or via classic inclusion mode SmartStart Inclusion Steps:1. Initiate add sensor flow in the Ring Alarm mobile applicationFollow the guided add flow instructions provided in the application2. Scan the QR code found on the package of the sensor or the QR code found on the back of the sensor3. Pull the battery tab on the sensor4. When the inclusion process in complete, the LED on the sensor will be solid blue, then go out.5. Test the sensor.Place the sensor in an unoccupied room. Leave the room for at least four minutes. Return to the room and pass in front of the sensorLED will flash if motion is detected.Classic Inclusion Steps:1. Initiate add sensor flow in the Ring Alarm mobile applicationFollow the guided add flow instructions provided in the application2. Select add manually and enter the 5 digit DSK pin found on the package of the sensor or the QR code found on the back of the sensor3. Pull the battery tab on the sensor4. When the inclusion process in complete, the LED on the sensor will be solid blue, then go out.5. Test the sensor.Place the sensor in an unoccupied room. Leave the room for at least four minutes. Return to the room and pass in front of the sensorLED will flash if motion is detected.
Exklusion
Exclusion Instructions:1.Initiate remove sensor flow in the Ring Alarm mobile applicationSelect the settings icon from device details page and choose Remove Device2.Open motion sensors cover3.Remove and replace battery quickly
Kommunikation zu einem schlafenden Gerät (Wakeup)
Die folgenden kleinen Hinweise können bei Problemen im Z-Wave Netz helfen.
Z-Wave Geräte können andere Geräte direkt steuern. Diese direkte Steuerung heißt in Z-Wave Assoziation. In den steuernden Geräten muss dazu die Geräte-ID des zu steuernden Gerätes hinterlegt werden. Dies erfolgt in sogenannten Assoziationsgruppen. Eine Assoziationsgruppe ist immer an ein Ereignis im steuernden Gerät gebunden (Tastendruck oder Auslösen eines Sensors). Bei Eintritt dieses Ereignisses wird an alle in einer Assoziationsgruppe hinterlegten Geräte ein Steuerkommando - meist ein BASIC SET - gesendet.
Gruppen-Nummer | Max. Anzahl Geräte | Beschreibung |
---|---|---|
1 | 1 | Z-Wave Plus Lifeline group - Notification and Battery reports to associated nodes |
2 | 1 | Z-Wave Basic Group - will send a basic report of either 0xFF for motion or 0x00 for no motion. |
Z-Wave Produkte können direkt nach der Inklusion im Netz verwendet werden. Durch Konfigurationseinstellungen kann das Verhalten des Gerätes jedoch noch besser an die Anforderungen der Anwendung angepasst und zusätzliche Funktionen aktiviert werden.
WICHTIG: Manche Steuerungen erlauben nur die Konfiguration von vorzeichenbehafteten Werten zwischen -128 und 127. Um erforderliche Werte zwischen 128 und 255 zu programmieren, muss der gewünschte Wert minus 256 eingegeben werden. Beispiel: um einen Parameter auf einen Wert von 200 zu setzen, müsste der Wert 200-256 = -56 eingegeben werden, wenn nur positive Werte bis 128 akzeptiert werden. Bei Werten von 2 Byte Länge wird die gleiche Logik angewandt: Werte über 32768 werden als negative Werte angegeben.
Configures how often the sensor should send an unsolicited Battery Report to the Lifeline255 to 4200 seconds in 255 second increments that the sensor should wait between sending unsolicited battery reports. Grösse: 2 Byte, Voreingestellt: 0
Wert | Beschreibung |
---|---|
255 - 4200 | 255 to 4200 seconds |
Configures the dwell window or how long the sensor should not be detecting motion before sending the no motion detected message. 1 to 9 minutes. Grösse: 1 Byte, Voreingestellt: 3
Wert | Beschreibung |
---|---|
1 - 9 | 1 to 9 minutes. |
Configures the Pet Immunity, or sensitivity of the motion detection used mostly so only human motion is detected.0 to 2 sensitivity.0: No pet immunity1: 15kg (33lb)2:25kg (55lb) Grösse: 1 Byte, Voreingestellt: 2
Wert | Beschreibung |
---|---|
0 | No pet immunity |
1 | 15kg (33lb) |
2 | 25kg (55lb) |
Parameter 4 is used to activate a walk test mode to test the PIR motion detection coverage after being installed. This mode is active for 15 minutes only after which the sensor returns to normal operation.0: Normal operation0xFF: Activate Walk Test for 15 minutes Grösse: 1 Byte, Voreingestellt: 0
Wert | Beschreibung |
---|---|
0 | Normal operation |
255 | Activate Walk Test for 15 minutes |
Z-Wave Hardware Platform | ZM5202 |
Gerätetyp | Notification Sensor |
Netzwerkfunktion | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 10.07 |
Z-Wave Version | 6.80.00 |
Zertifizierungs-ID | ZC10-18066145 |
Z-Wave Produkt Id | 0x0346.0x0301.0x0201 |
Supported Notification Types | Home Security |
Color | White |
Firmware Updatable | Updatable by Manufacturer |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequenz | XXfrequency |
Maximale Sendeleistung | XXantenna |