Connect module to power supply (with temperature sensor connected - if purchased),auto-inclusion (works for about 5 seconds after connected to power supply) orpress service button S for more than 2 second orpress push button I1 three times within 3s (3 times change switch state within 3 seconds).NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply.NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply, connect the sensor and re-include the module.
Z-Wave ist der internationale Funkstandard zur Kommunikation von Geräten im intelligenten Haus. Dies ist ein Z-Wave Gerät und nutzt die im Quickstart angegebene Funkfrequenz.
Dank Z-Wave können Produkte unterschiedlicher Hersteller miteinander in einem Funknetz verwendet werden. Damit ist auch dieses Produkt mit beliebigen anderen Produkten anderer Hersteller in einem gemeinsamen Z-Wave Funknetz einsetzbar.
Wenn ein Gerät die spezielle sichere Kommunikation unterstützt dann wird es immer dann mit einem anderen Gerät sicher kommunizieren, wenn dieses Gerät auch eine sichere Kommunikation unterstützt. Ansonsten wird aus Kompatibilitätsgründen auf einen normalen Kommunikation umgeschaltet.
Weitere Informationen wie Produktneugkeiten, Tutorials, Supportforen etc. erhalten Sie auf www.zwave.de.
The Qubino Flush Shutter DC is ideal for controlling the 1224V DC motors of blinds, rollers, shades, venetian blinds and similar sunscreens. You can control it either remotely through the Z-Wave network or through wall switches. It also measures power consumption and supports the connection of a digital temperature sensor.
Bitte lesen Sie die Benutzeranleitung bevor Sie das Gerät in Betrieb nehmen.
Damit ein Z-Wave zu einem neuen Netz hinzugefügt werden kann muss es sich im Auslieferungs- oder Reset-Zustand befinden. Im Zweifel ist es sinnvoll, eine Exklusion durchzuführen, um das Gerät ganz sicher in diesem Zustand zu bringen. Diese Exklusion kann von jedem beliebigen Z-Wave Controller durchgeführt werden.
Dieses Gerät kann auch ohne Hilfe eines Controller in den Reset-Zustand zurückgeführt werden. Dies sollte jedoch nur dann gemacht werden wenn der Primärcontroller des Z-Wave-Netzes nicht mehr verfügbar oder defekt ist.
press service button S for more than 6 second orpress push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply.By this function all parameters of the module are set to default values and own ID is deleted.NOTE: Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Achtung: Je nach nationalen Sicherheitsnormen kann es nur autorisierten und/oder ausgebildeten Techniker erlaubt sein, elektrische Installationen am Spannungsnetz vorzunehmen. Bitte informieren Sie sich vor der Installation über die Rechtslage.
Im Auslieferungszustand ist das Gerät mit keinem Z-Wave-Netz verbunden. Damit es
mit anderen Z-Wave Geräten kommunizieren kann, muss es in ein bestehendes Z-Wave Netz
eingebunden werden. Dieser Prozess wird bei Z-Wave Inklusion genannt. Geräte können
Netzwerke auch wieder verlassen. Dieser Prozess heißt bei Z-Wave Exklusion. Beide
Prozesse werden von einem Controller gestartet, der dazu in einen Inklusion- bzw.
Exklusion-Modus geschaltet werden muss. Das Handbuch des Controllers enthält
Informationen, wie er in diese Modi zu schalten ist. Erst wenn der Controller
des Z-Wave Netzes im Inclusion-Modus ist, können Geräte hinzugefügt werden.
Das Verlassen des Netzes durch Exklusion führt zum Rücksetzen dieses Gerätes
in den Auslieferungszustand.3>
Inklusion
Connect module to power supply (with temperature sensor connected - if purchased),auto-inclusion (works for about 5 seconds after connected to power supply) orpress service button S for more than 2 second orpress push button I1 three times within 3s (3 times change switch state within 3 seconds).NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply.NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply, connect the sensor and re-include the module.
Exklusion
Connect module to power supply bring module within maximum 1 meter (3 feet) of the main controller,enable add/remove mode on main controller,If service button S is pressed more than 2 and less than 6 seconds (or if push button I1 is pressed three times within 3s) module is excluded, but configuration parameters are not set to default values.NOTE: Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Die folgenden kleinen Hinweise können bei Problemen im Z-Wave Netz helfen.
Z-Wave Geräte können andere Geräte direkt steuern. Diese direkte Steuerung heißt in Z-Wave Assoziation. In den steuernden Geräten muss dazu die Geräte-ID des zu steuernden Gerätes hinterlegt werden. Dies erfolgt in sogenannten Assoziationsgruppen. Eine Assoziationsgruppe ist immer an ein Ereignis im steuernden Gerät gebunden (Tastendruck oder Auslösen eines Sensors). Bei Eintritt dieses Ereignisses wird an alle in einer Assoziationsgruppe hinterlegten Geräte ein Steuerkommando - meist ein BASIC SET - gesendet.
Gruppen-Nummer | Max. Anzahl Geräte | Beschreibung |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline |
2 | 15 | Basic on/off (triggered at change of the input I1 state and reflecting its state) |
3 | 16 | Basic on/off (triggered at change of the input I2 state and reflecting its state) |
4 | 16 | Basic on/off (triggered at sensing moving direction of roller: up=FF, down=0) |
5 | 16 | Basic on/off (triggered at reaching roller position: bottom=FF, top=0) |
6 | 16 | Basic on/off (triggered at reaching roller position: bottom=FF, not bottom=0) |
7 | 16 | Multilevel set (triggered at changes of value of the Flush Shutter DC position) |
8 | 16 | Multilevel set (triggered at changes of value of slats tilting position) |
9 | 16 | Multilevel sensor report (triggered at change of temperature sensor |
Z-Wave Produkte können direkt nach der Inklusion im Netz verwendet werden. Durch Konfigurationseinstellungen kann das Verhalten des Gerätes jedoch noch besser an die Anforderungen der Anwendung angepasst und zusätzliche Funktionen aktiviert werden.
WICHTIG: Manche Steuerungen erlauben nur die Konfiguration von vorzeichenbehafteten Werten zwischen -128 und 127. Um erforderliche Werte zwischen 128 und 255 zu programmieren, muss der gewünschte Wert minus 256 eingegeben werden. Beispiel: um einen Parameter auf einen Wert von 200 zu setzen, müsste der Wert 200-256 = -56 eingegeben werden, wenn nur positive Werte bis 128 akzeptiert werden. Bei Werten von 2 Byte Länge wird die gleiche Logik angewandt: Werte über 32768 werden als negative Werte angegeben.
Flush Shutter DCs module responds to commands ALL ON / ALL OFF that may be sent by the primary or secondary controller within the Z-Wave network. Grösse: 2 Byte, Voreingestellt: 255
Wert | Beschreibung |
---|---|
0 | ALL ON is not active, ALL OFF is not active |
1 | ALL ON is not active ALL OFF active |
2 | ALL ON active ALL OFF is not active |
255 | ALL ON active, ALL OFF active |
Set value is added to or subtracted from the actually measured value to adjust the temperature report sent by an external sensor (sold separately). This parameter only applies to the degrees temperature unit (the Fahrenheit unit is currently not supported). Grösse: 2 Byte, Voreingestellt: 32536
Wert | Beschreibung |
---|---|
1 - 100 | value from 0.1 degrees Celsius to 10.0 degrees Celsius is added to actual measured temperature. |
1001 - 1100 | value from -0.1 degrees Celsius to -10.0 degrees Celsius is subtracted to actual measured temperature. |
32536 | offset is 0.0C |
If an external digital temperature sensor (sold separately) is connected to the module, it reports temperature readings based on the threshold defined in this parameter. This parameter only applies to the degrees temperature unit (the Fahrenheit unit is currently not supported). Grösse: 1 Byte, Voreingestellt: 5
Wert | Beschreibung |
---|---|
1 - 127 | = 0,1 degrees Celsius - 12,7 degrees Celsius, step is 0,1 degrees Celsius |
5 | = 0,5 degrees Celsius |
Choose by how much power consumption needs to increase or decrease to be reported. Values correspond to percentages so if 10 is set (by default), the module will report any power consumption changes of 10% or more compared to the last reading. NOTE: Power consumption needs to increase or decrease by at least 1 Watt to be reported, REGARDLESS of percentage set in this parameter. Grösse: 1 Byte, Voreingestellt: 10
Wert | Beschreibung |
---|---|
0 | reporting disabled |
1 - 100 | = 1% - 100% Reporting enabled. Power report is send (push) only when actual power (in Watts) in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%. |
10 | default value |
The set value refers to the time interval with which the power consumption in Watts is reported (032767 seconds). If 0 is entered (by default), energy consumption reports will not be sent to the controller. Grösse: 2 Byte, Voreingestellt: 0
Wert | Beschreibung |
---|---|
0 | reporting disabled |
1 - 32767 | = 1 second - 32767 seconds. Reporting enabled, power report is send with |
Choose between the two operating modes. If the venetian mode is selected, an additional widget/endpoint will be displayed on the UI interface, which can be used to control the tilt position of the slats. If the Shutter mode is selected, this additional endpoint is hidden.NOTE1: After the value of this parameter is changed, first exclude module (without setting parameters to their default values), wait at least 30s and then reinclude the module! Grösse: 1 Byte, Voreingestellt: 0
Wert | Beschreibung |
---|---|
0 | shutter mode |
1 | venetian mode (up/down and slate rotation) |
Set the time, required by the slats, to make a full turn (180 degrees). NOTE: If the set time is too long and a full turn was already performed, the device will start to move up or down for the remaining time. Grösse: 2 Byte, Voreingestellt: 150
Wert | Beschreibung |
---|---|
0 | tilting time disabled |
1 - 32767 | = 0,01seconds - 327,67 seconds |
150 | = 1,5 seconds |
Choose the position of the slats after up/down movement (activated through the Z-Wave controller or the push-buttons) is completed. Grösse: 1 Byte, Voreingestellt: 1
Wert | Beschreibung |
---|---|
0 | Slats return to previously set position only in case of Z-wave control (not valid for limit switch positions) |
1 | Slats return to previously set position in case of Z-wave control, push-button operation or when the lower limit switch is reached |
This parameter defines the time, required by the Shutter DC motor, to completely open or completely close the attached shutters.After the set time passes, the motor stops (relay goes to the off state).NOTE: It is important that the reference position, for setting the moving time, is always when the Shutter is at its lowest position!Set parameter 74 to 0 and move the Shutter (using the up/down push-buttons or the main controller UI) to the lowest desired position. When the Shutter reaches this position, set the parameter 74 to the duration, required by the Shutter, to completely open or completely close the attached shutters. At this point the Shutter can be moved up (open), but can't be moved down, because this position is already set as its lowest position.To change the defined lowest position of the Shutter below the one, which is already defined (manual recalibration), the parameter 74 must be set to 0 and the procedure, which is described above, should be repeated.In case the Shutter operates using limit switches, but the user still wants to control the opening/closing position with time, this is still possible. If a time duration, which is longer than the opening/closing time of the shutters in real time (limited by the limit switches), is set, the Shutter will stop at the limit switches, but the module relay will switch it off after a defined time, not by the limit switch of the Shutter. Take into consideration that in this condition, positioning the shutters with the slider (through the UI) will not display the correct position of the Shutter. Grösse: 2 Byte, Voreingestellt: 0
Wert | Beschreibung |
---|---|
0 | moving time disabled (working with limitswitches) |
1 - 32767 | = 0,1seconds - 3276,7seconds. After that time motor is stopped (relay goes to off state) |
Define the power consumption threshold at the end positions. Based on this value, the device will know, that the shutters reached the limit switches. Grösse: 1 Byte, Voreingestellt: 6
Wert | Beschreibung |
---|---|
5 - 100 | = (0,5W - 10W), step is 0,1W. |
6 | = 0,6W |
By changing the value of this parameter from 0 to 1, the Shutter enters the calibration mode. For further information about the calibration process, please see section 9. Grösse: 1 Byte, Voreingestellt: 0
Wert | Beschreibung |
---|---|
0 | default value |
1 | start calibration process (when calibration process is finished, completing full cycle - up, down and up, set the parameter 78 (Forced Shutter calibration) value back to 0 |
Define the maximum time before the power consumption of the motor, after one of the relays is switched ON, is read from the device. If there is no power consumption during the set time (motor not connected, damaged or requires longer time to start, motor at the end position), the relay will switch OFF. This time is defined by entering it manually. Grösse: 1 Byte, Voreingestellt: 8
Wert | Beschreibung |
---|---|
3 - 50 | = 0,3seconds - 5seconds (100ms resolution) |
8 | = 800ms |
This parameter defines the maximum time after which the active output will switch off, due to reaching a limit switch. When power consumption is below the specified power threshold, defined in the parameter no. 76, the set time duration will have to pass in order for the output to turn off. Grösse: 1 Byte, Voreingestellt: 8
Wert | Beschreibung |
---|---|
3 - 50 | = 0,3seconds - 5seconds (100ms resolution) |
8 | 8 = 800ms |
This parameter defines the minimum time duration between successive motor movements (minimum time after which the motor is switched off and on again). Grösse: 1 Byte, Voreingestellt: 5
Wert | Beschreibung |
---|---|
1 - 30 | = 0,1seconds - 3seconds (100ms resolution) |
5 | = 500ms |
Z-Wave Hardware Platform | ZM5202 |
Gerätetyp | Window Covering - Pos/End Aware |
Netzwerkfunktion | Always On Slave |
Firmware Version | HW: 1 FW: 6.04:06.05 |
Z-Wave Version | 6.51.09 |
Zertifizierungs-ID | ZC10-18066155 |
Z-Wave Produkt Id | 0x0159.0x0003.0x0053 |
Supported Notification Types | Power Management |
Window Covering Control Features | Automatic CalibrationEndpoint AwareManual CalibrationPosition AwareSupports CurtainsSupports Open/Close MotionSupports Tilt MotionSupports Vertical Blinds |
Sensors | Air Temperature |
Color | Light Blue |
Supported Meter Type | Electric Energy |
Frequenz | XXfrequency |
Maximale Sendeleistung | XXantenna |