This is a
Add Multi-Sensor into a Z-Wave network:a. Let the primary controller go into inclusion mode (If you dont know how to do this, refer to its manual). b. Short Press one time this Z-Button. c. The Multi-Sensor LED will blink, If the inclusion is successful, then LED will keep on 2 seconds. Otherwise, the LED will blink until timeout, in which case you need to repeat the process from step b.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
The Multi sensor is designed for use with scenes in home automation systems, integrate motion, light, temperature and humidity sensors, powered by CR123A battery or USB cable. The Motion Sensor lets you know when movement is detected in a certain area and can trigger different actions in response to that movement (or lack of movement). It also lets you know the ambient temperature and humidity to trigger different actions to make you more comfort.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Reset Multi-Sensor to factory Default:1. Press and hold the Z-Button for 5seconds.2. If holding time is more than 5seconds, the LED will blink fast at acceleration. If reset success Multi-Sensor LED will turn off. When the Z-Button is released, it will send Device Reset Locally Command. Otherwise please repeat step 2.Note: 1, This procedure should only be used when the primary controller is inoperable.2, Reset Multi-Sensor to factory default settings.It will set the Multi-Sensor to not in Z-Wave network state; delete the Association setting and restore the Configuration setting to the default.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline1. Notification Report.Sensor will send Notification Report when Motion Detection Unknown Location and (Event inactive).2. Multilevel Sensor ReportSensor will send Multilevel Sensor Report (Temperature, humidity, luminance) interval of 2 hours.3. Battery Report.Sensor will send Battery Report when the battery level is low and the battery reports value is 0xFF.4. Device Reset Locally. |
2 | 5 | Send Basic Set when PIR trigger |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Low Battery Power Level of alarm threshold values: the value range are 10~50 for percentage, so the Battery Low Power level can setting 10%~50%. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
10 - 50 | Low Battery Power Level of alarm threshold values |
Set 101 ~ 104 to default. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Set 101 ~ 104 to default. |
The interval time of sending the temperature reporting. if setting to 0 then the temperature reporting is disabled 1. Valid values: 0x00-0x28DE802. The minimum interval time is 1 minutes. For example, if the value is set to be more than 1 and less than 60, the interval time is 1 minutes, if the value is set to be more than 60 and less than 120, the interval time is 2 minutes. Size: 4 Byte, Default Value: 7200
Setting | Description |
---|---|
0 | the temperature reporting is disabled |
1 - 2678400 | The interval time of sending the temperature reporting is 31 days2678400 seconds |
The interval time of sending the humidity reporting. if setting to 0 then the humidity reporting is disabled 1. Valid values: 0x00-0x28DE802. The minimum interval time is 1 minutes. For example, if the value is set to be more than 1 and less than 60, the interval time is 1 minutes, if the value is set to be more than 60 and less than 120, the interval time is 2 minutes. Size: 4 Byte, Default Value: 7200
Setting | Description |
---|---|
0 | the humidity reporting is disabled |
1 - 2678400 | The interval time of sending the humidity reporting is 31 days2678400 seconds |
The interval time of sending the luminance reporting. if setting to 0 then the luminance reporting is disabled 1. Valid values: 0x00-0x28DE802. The minimum interval time is 1 minutes. For example, if the value is set to be more than 1 and less than 60, the interval time is 1 minutes, if the value is set to be more than 60 and less than 120, the interval time is 2 minutes. Size: 4 Byte, Default Value: 7200
Setting | Description |
---|---|
0 | the luminance reporting is disabled |
1 - 2678400 | The interval time of sending the luminance reporting is 31 days2678400 seconds |
The interval time of sending the battery level reporting. if setting to 0 then the battery level reporting is disabled 1. Valid values: 0x00-0x28DE802. The minimum interval time is 1 minutes. For example, if the value is set to be more than 1 and less than 60, the interval time is 1 minutes, if the value is set to be more than 60 and less than 120, the interval time is 2 minutes. Size: 4 Byte, Default Value: 86400
Setting | Description |
---|---|
0 | the battery level reporting is disabled |
1 - 2678400 | The interval time of sending the battery level reporting is 31 days2678400 seconds |
Enable 111 ~ 114 temperature/humidity/luminance/ battery level change reporting.0 = Unable1 = Enable Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Unable |
1 | Enable |
Configuration temperature change threshold.Valid values: 1-500(unit 0.1) Size: 2 Byte, Default Value: 10
Setting | Description |
---|---|
1 - 500 | the temperature change threshold value(unit 0.1) |
Configuration humidity change threshold.Valid values: 1-32(unit %) Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 32 | humidity change threshold value(unit %) |
Configuration luminance change threshold.Valid values: 1-65528(unit lx) Size: 2 Byte, Default Value: 150
Setting | Description |
---|---|
-32767 - -1 | luminance change threshold is 32767 to 65528 |
0 - 32766 | luminance change threshold is 0 to 32766 |
Configuration battery level change threshold.Valid values: 1-100(unit %) Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
1 - 100 | battery level change threshold value(unit)% |
Turn on/off PIR 0x0A indicates the highest sensitivity, 0x00 means off PIR detection function. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 10 | 0x0A indicates the highest sensitivity, 0x00 means off PIR detection function. |
PIR triggers the waiting time value Size: 2 Byte, Default Value: 30
Setting | Description |
---|---|
5 - 15300 | the waiting time of the PIR triggering |
Whether the BASIC SET command is sent after the PIR is triggered Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Unable |
1 | Enable |
PIR triggers the correspondence between the value of the Basic set and the PIR state, When value is 0x00 PIR triggers Send the basic set command 0xff PIR alarm release send the basic set command 0x00, otherwise PIR triggers send the basic set command 0x00 PIR alarm release send the basic set command 0xff. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | PIR triggers Send the basic set command 0xff PIR alarm release send the basic set command 0x00 |
1 | PIR triggers send the basic set command 0x00 PIR alarm release send the basic set command 0xff. |
Hardware Platform | ZM5101 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 3 FW: 2.01 |
Z-Wave Version | 6.81.00 |
Certification ID | ZC10-18106256 |
Z-Wave Product Id | 0x0300.0x0200.0x0009 |
Supported Notification Types | Luminance |
Sensors | Air TemperatureHumidityLuminanceMotion/No Motion (Binary) |
Firmware Updatable | Updatable by Consumer by RF |
Security V2 | S2_UNAUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |