Quickstart

This is a secure On/Off Power Switch for CEPT (Europe). To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
1. Put the controller into ADD device mode. Follow the instructions provided by the controller manufacturer.2. Touch and hold any key on the panel for more than 5 seconds. All indication lights will blink in blue color. At this point release the key, the touch panel will start the inclusion process.

Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.


Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.

This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.

If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.

Product Description

A Smart Home deserves something much better than an ordinary switch. Hogar touch panels are a one-of-a-kind collection of switches, dimmers, and scene controllers that will transform walls from boring to absolutely, breath-taking.Hogar Touch Panels are a fine amalgamation of beauty, style, convenience and functionality. The smooth, gleaming, glossy and glass effect Touch Panels challenge common perceptions of a light switch, electrical socket or dimmer and add a touch of elegance to your smart home.The Hogar Controls ten-touch panels feature a stunning glass face with advanced capacitive touch sensors. It allows users to turn the devices on/off with a touch. The red/blue illumination clearly indicates its working state.A one of a kind solution for all your smart home needs, the mechanical structure of the ten-touch panel provides you with the flexibility of suiting any gang box size of US standard electrical boxes. It is simple to install and easy to use with its innovative assembly, plug-and-play feature and completely retrofit design.These Touch Panels are designed for a wide range of purposes where every button can be programmed to work either in switch or scene mode. Combine switches, fan dimmers, light dimmers and scene controllers at the comfort of your conventional gang boxes.The innovative design and chic styling coupled with advanced functionalities make it a delight for users.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.

Using a screwdriver press the config button 5 times.All indication lights will blink in red color. Touch panel will start local reset. Touch panel switch will erase network inclusion state after local reset. Please use this procedure only when the network primary controller is missing or otherwise inoperable.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.

Inclusion

1. Put the controller into ADD device mode. Follow the instructions provided by the controller manufacturer.2. Touch and hold any key on the panel for more than 5 seconds. All indication lights will blink in blue color. At this point release the key, the touch panel will start the inclusion process.

Exclusion

1. Put the controller into REMOVE device mode. Follow the instructions provided by the controller manufacturer.2. Touch and hold any key on the panel for more than 5 seconds. All indication lights will blink in blue color. At this point release the key, the touch panel will start the exclusion process.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association - one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.

Association Groups:

Group Number Maximum Nodes Description
1 5 Name: LifelineCommand:Device Reset Locally NotificationSwitch Binary Report
2 5 Name: HGT-01Command:Basic SetSend Basic Set command to the other node in this association group when active endpoint 1.
3 5 Name: HGT-01Command:Switch Binary SetSend Switch Binary Set command to the other node in this association group when active endpoint 1.
4 5 Name: HGT-02Command:Basic SetSend Basic Set command to the other node in this association group when active endpoint 2.
5 5 Name: HGT-02Command:Switch Binary SetSend Switch Binary Set command to the other node in this association group when active endpoint 2.
6 5 Name: HGT-03Command:Basic SetSend Basic Set command to the other node in this association group when active endpoint 3.
7 5 Name: HGT-03Command:Switch Binary SetSend Switch Binary Set command to the other node in this association group when active endpoint 3.
8 5 Name: HGT-04Command:Basic SetSend Basic Set command to the other node in this association group when active endpoint 4.
9 5 Name: HGT-04Command:Switch Binary SetSend Switch Binary Set command to the other node in this association group when active endpoint 4.

Technical Data

Hardware Platform ZM5202
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 2 FW: 2.05
Z-Wave Version 6.81.01
Certification ID ZC10-18116304
Z-Wave Product Id 0x0293.0x0003.0x441A
Loads Controlled 8
Neutral Wire Required ok
Electric Load Type Dimmable ELV (Magnetic)Dimmable FluorescentDimmable LEDDimmable MLV (Magnetic)ELV (Electronic)FluorescentIncandescentInductive (e.g. Motor)LEDMLV (Magnetic)
Firmware Updatable Updatable by Professional/Technician
Security V2 S2_UNAUTHENTICATED
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

Controlled Command Classes

Explanation of Z-Wave specific terms