Dies ist ein
The sensor supports Auto Inclusion feature where it will automatically enter Inclusion mode when firstpowered up after a factory reset.1. Use a screwdriver to detach the rear cover.2. Put a Z-Wave Controller into inclusion mode.3. Insert 1 CR123 3V battery to the battery compartment with the correct polarity. The LED on the device should turn ON.4. The Inclusion process should be completed when the LED stops blinking.5. Do not refit the rear cover yet and proceed to the Testing section before mounting.Note: If Auto Inclusion fails, refer to the Troubleshooting section regarding Manual Inclusion.1. Put the Z-Wave Controller into Inclusion mode2. Press the tamper switch 3 times within 1.5seconds to put the unit into inclusion mode
Z-Wave ist der internationale Funkstandard zur Kommunikation von Geräten im intelligenten Haus. Dies ist ein Z-Wave Gerät und nutzt die im Quickstart angegebene Funkfrequenz.
Dank Z-Wave können Produkte unterschiedlicher Hersteller miteinander in einem Funknetz verwendet werden. Damit ist auch dieses Produkt mit beliebigen anderen Produkten anderer Hersteller in einem gemeinsamen Z-Wave Funknetz einsetzbar.
Wenn ein Gerät die spezielle sichere Kommunikation unterstützt dann wird es immer dann mit einem anderen Gerät sicher kommunizieren, wenn dieses Gerät auch eine sichere Kommunikation unterstützt. Ansonsten wird aus Kompatibilitätsgründen auf einen normalen Kommunikation umgeschaltet.
Weitere Informationen wie Produktneugkeiten, Tutorials, Supportforen etc. erhalten Sie auf www.zwave.de.
Eaton's Z-Wave Plus battery operated motion sensoris a versatile motion detector that can be triggered by movement or changes in light level when paired with your Home automation or a Security system.Detects motion in a space with in-built Passive Infra-red and Light SensorWhen used with a compatible Smart Hub, get alerted on your smart phone or Tablet, trigger scenes or have lights come ON automaticallyCR123A Lithium Battery included with the product ~ expected battery life of 2 yearsCan be mounted using included screws or double sided tape120 field of view with 1032 sq. ft coverage for Major motionSupports Z-Wave Plus functionality with S2 security certification
Bitte lesen Sie die Benutzeranleitung bevor Sie das Gerät in Betrieb nehmen.
Damit ein Z-Wave zu einem neuen Netz hinzugefügt werden kann muss es sich im Auslieferungs- oder Reset-Zustand befinden. Im Zweifel ist es sinnvoll, eine Exklusion durchzuführen, um das Gerät ganz sicher in diesem Zustand zu bringen. Diese Exklusion kann von jedem beliebigen Z-Wave Controller durchgeführt werden.
Dieses Gerät kann auch ohne Hilfe eines Controller in den Reset-Zustand zurückgeführt werden. Dies sollte jedoch nur dann gemacht werden wenn der Primärcontroller des Z-Wave-Netzes nicht mehr verfügbar oder defekt ist.
This procedure should only be used when the controller is inoperable:1. Press the tamper switch 3 times within 1.5seconds to put the unit into exclusion mode2. Within 1 second of step 1, press the tamper switchagain and hold until LED is off (about 5 seconds)3. Node ID is excluded. The device reverts to factorydefault state and will be in auto-inclusion mode for4 minutes
Im Auslieferungszustand ist das Gerät mit keinem Z-Wave-Netz verbunden. Damit es
mit anderen Z-Wave Geräten kommunizieren kann, muss es in ein bestehendes Z-Wave Netz
eingebunden werden. Dieser Prozess wird bei Z-Wave Inklusion genannt. Geräte können
Netzwerke auch wieder verlassen. Dieser Prozess heißt bei Z-Wave Exklusion. Beide
Prozesse werden von einem Controller gestartet, der dazu in einen Inklusion- bzw.
Exklusion-Modus geschaltet werden muss. Das Handbuch des Controllers enthält
Informationen, wie er in diese Modi zu schalten ist. Erst wenn der Controller
des Z-Wave Netzes im Inclusion-Modus ist, können Geräte hinzugefügt werden.
Das Verlassen des Netzes durch Exklusion führt zum Rücksetzen dieses Gerätes
in den Auslieferungszustand.3>
Das Gerät ist batteriegespeist und damit in der Regel in einem Tiefschlafmodus um
Strom zu sparen. Im Tiefschlafmodus kann das Gerät keine Funksignale empfangen. Daher
wird ein (statischer) Controller benötigt, der netzgespeist und damit immer
funkaktiv ist. Dieser Controller - zum Beispiel ein IP-Gateway - verwaltet eine
Nachrichten-Mailbox für dieses batteriegespeiste Gerät, in dem Nachrichten an dieses
Gerät zwischengespeichert werden. Ohne einen solchen statischen Controller wird die
Nutzung dieses batteriebetriebenen Gerätes sehr schnell zur Entladung der Batterie
führen oder die Nutzung ist komplett unmöglich. Dieses Gerät weckt regelmäßig auf, meldet dies durch Aussenden einer sogenannten
Wakeup-Notifikation und leert dann seine Mailbox im statischen Controller. Dafür
muss bei der Inclusion die Node-ID des Controllers und ein Aufweckinterval
definiert werden. Erfolgt die Inklusion durch einen statischen Controller
wie zum Beispiel ein IP-Gateway, wird dieser Controller diese Konfiguration
automatisch erledigen und in der Regel eine Nutzerschnittstelle anbieten, um das
Aufweck-Interval den Nutzerbedürfnissen anzupassen. Das Aufweckinterval ist ein
Kompromiss zwischen maximaler Batterielaufzeit und minimaler Reaktionszeit des
batteriegespeisten Gerätes. Um das Gerät manuell aufzuwecken, führen Sie die folgende Aktion durch:
After it has been included into a Z-Wave network, the sensor will go to sleep but will send a WakeupNotification Command periodically at preset interval to the controller. The Motion sensor will stayawake for at least 10 seconds and then go back to sleep to conserve battery life.The time interval between Wakeup Notification Commands can be set in the Wakeup Command Classbased on the range values below:Minimum Wake Up Interval: 600s (10 minutes)Maximum Wake Up Interval: 86400s (1 day)Default Wake Up Interval: 14400s (4 hours)Wake Up Interval Step Seconds: 600s (10 minutes) Inklusion
The sensor supports Auto Inclusion feature where it will automatically enter Inclusion mode when firstpowered up after a factory reset.1. Use a screwdriver to detach the rear cover.2. Put a Z-Wave Controller into inclusion mode.3. Insert 1 CR123 3V battery to the battery compartment with the correct polarity. The LED on the device should turn ON.4. The Inclusion process should be completed when the LED stops blinking.5. Do not refit the rear cover yet and proceed to the Testing section before mounting.Note: If Auto Inclusion fails, refer to the Troubleshooting section regarding Manual Inclusion.1. Put the Z-Wave Controller into Inclusion mode2. Press the tamper switch 3 times within 1.5seconds to put the unit into inclusion mode
Exklusion
1. Put the Z-Wave Controller into Exclusion mode2. Press the tamper switch 3 times within 1.5seconds to put the unit into exclusion mode
Kommunikation zu einem schlafenden Gerät (Wakeup)
Die folgenden kleinen Hinweise können bei Problemen im Z-Wave Netz helfen.
Z-Wave Geräte können andere Geräte direkt steuern. Diese direkte Steuerung heißt in Z-Wave Assoziation. In den steuernden Geräten muss dazu die Geräte-ID des zu steuernden Gerätes hinterlegt werden. Dies erfolgt in sogenannten Assoziationsgruppen. Eine Assoziationsgruppe ist immer an ein Ereignis im steuernden Gerät gebunden (Tastendruck oder Auslösen eines Sensors). Bei Eintritt dieses Ereignisses wird an alle in einer Assoziationsgruppe hinterlegten Geräte ein Steuerkommando - meist ein BASIC SET - gesendet.
Gruppen-Nummer | Max. Anzahl Geräte | Beschreibung |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline |
2 | 4 | Basic SetPIR Control |
Z-Wave Produkte können direkt nach der Inklusion im Netz verwendet werden. Durch Konfigurationseinstellungen kann das Verhalten des Gerätes jedoch noch besser an die Anforderungen der Anwendung angepasst und zusätzliche Funktionen aktiviert werden.
WICHTIG: Manche Steuerungen erlauben nur die Konfiguration von vorzeichenbehafteten Werten zwischen -128 und 127. Um erforderliche Werte zwischen 128 und 255 zu programmieren, muss der gewünschte Wert minus 256 eingegeben werden. Beispiel: um einen Parameter auf einen Wert von 200 zu setzen, müsste der Wert 200-256 = -56 eingegeben werden, wenn nur positive Werte bis 128 akzeptiert werden. Bei Werten von 2 Byte Länge wird die gleiche Logik angewandt: Werte über 32768 werden als negative Werte angegeben.
The Basic Set Level determines the value that will be sent from the Basic Set command for devicesassociated with Group 2. For a Binary Switch Device (e.g., receptacle or appliance module), it will bea simple ON command. For a Multilevel Switch Device (e.g., a dimmer), it will be set to the level setby this parameter. Grösse: 1 Byte, Voreingestellt: 99
Wert | Beschreibung |
---|---|
1 - 99 | Basic Set Level |
In order to provide the best efficiency of the sensor, it is recommended to test the sensor withmovements from the farthest end of the coverage area at first time of use. If movements cannotbe detected consistently, simply adjust the sensitivity level with Configuration Parameter #3. Thisparameter can be configured with the value of 1 through 10, where 1 means low sensitivity and 10means high sensitivity. Grösse: 1 Byte, Voreingestellt: 6
Wert | Beschreibung |
---|---|
1 - 10 | Sensitivity level low (1) to high (10) |
The Re-trigger Interval Setting determines the amount of time between when the sensor will retriggera signal that motion has been detected. During this time, the sensor will not report motioneven though motion may be detected. The time interval can be set between 5 secs to 3600 secs. Grösse: 1 Byte, Voreingestellt: 180
Wert | Beschreibung |
---|---|
5 - 3600 | Time in seconds |
The user can set a lux level percentage which determines when the light sensor will be activated. Ifthe lux level of ambient illumination falls below this percentage, and motion is detected, the sensorwill emit a Z-Wave ON Command to the controller. Percentage can be set between 1% to 100%. Grösse: 1 Byte, Voreingestellt: 20
Wert | Beschreibung |
---|---|
1 - 100 | In percentages |
The function of on-off duration setting will be useful if the detector is connected with a module orlighting. The duration determines how long the module/lighting should stay ON. For instance, LampModule turns OFF 100 secs after it has been turned ON. This parameter can be configured with thevalue of 5 through 3600, where 5 means 5 second delay and 3600 means 3600 seconds of delay. Grösse: 2 Byte, Voreingestellt: 15
Wert | Beschreibung |
---|---|
5 - 3600 | In seconds |
Z-Wave Hardware Platform | SD3502 |
Gerätetyp | Notification Sensor |
Netzwerkfunktion | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 1.00:00.05 |
Z-Wave Version | 6.71.01 |
Zertifizierungs-ID | ZC10-18126337 |
Z-Wave Produkt Id | 0x001A.0x0042.0x0053 |
Firmware Updatable | Updatable by Consumer by RF |
Supported Notification Types | Luminance |
Color | White |
Sensors | LuminanceMotion/No Motion (Binary) |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequenz | XXfrequency |
Maximale Sendeleistung | XXantenna |