This is a
1.Put the Z-Wave Controller into inclusion mode, and press the pairing button 3 times in 2 seconds to include the module.2.Put the Z-Wave Controller into inclusion mode, and press the external swtich1 or external swtich2 3 times in 2 seconds to include the module.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Z-Wave Roller Shutter Controller is an ideal for the remotely electric motor controller. It is used to control the motors of rollers, shades, blinds, venetian blinds and similar sun shade, which are single phase AC powered. The module can be controlled either through a Z-Wave network or through the wall switch, and measures power consumption of motor.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
1.Press the pairing button 3 times in 2 seconds and press and hold the pairing button for more than 5 seconds at the 3rd time.2.The module is excluded and restores to factory default setting.3.Then the module will be in auto-inclusion mode for 2 minutes.Please use this procedure only when the network primary controller is missing or otherwise inoperable.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Z-Wave Plus Lifeline |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Positioning Calibration:0: Disable1: Executing calibration Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Positioning Calibration |
Set the power changed percentage to send the power report.0: Disabled1 - 100: 1% - 100% Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 100 | changed range |
Set the time interval of reporting watts in seconds.0: Disable60 - 32767: 60 - 32767sec Size: 2 Byte, Default Value: 300
Setting | Description |
---|---|
0 | disable |
60 - 32767 | times |
Set the time interval of reporting KWH in seconds.0: Disable60 - 32767: 60 - 32767sec Size: 1 Byte, Default Value: 3600
Setting | Description |
---|---|
0 | disable |
60 - 32767 | times |
External switch Protection:0: Enable external switch1: Disable external switch Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | External switch Protection |
When the door is opened, set the delay time for automatic closing.0: Disable automatic closing1 - 32767: The door will be closed automatically in 1 - 32767sec Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 32767 | delay time |
When the door is open, set the delay time for automatic notification0: Disable automatic notification1 - 32767: The notification will be sent automatically in 1 - 32767sec Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 32767 | delay time |
Set the operation mode:0: Roller Shutter1: Venetian (up/down and slate rotation) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Set the operation mode |
Angles of blinds00130260390412051506180 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 6 | Set the angle of blinds |
Set the slats turning time:1 - 127: 0.1 - 12.7 sec Size: 1 Byte, Default Value: 15
Setting | Description |
---|---|
1 - 127 | Set the slats turning time |
Set the delay time to start the motor up to the blade:0: No offset time1 - 127: 0.1 - 12.7 sec Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 127 | delay time |
Set the delay time to start the motor down to the blade.0: No offset time1 - 127: 0.112.7 sec Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 127 | delay time |
Hardware Platform | ZM5101 |
Device Type | Window Covering - Pos/End Aware |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 2.00 |
Z-Wave Version | 6.81.00 |
Certification ID | ZC10-19036390 |
Z-Wave Product Id | 0x0068.0x0003.0x0014 |
Firmware Updatable | Updatable by Manufacturer |
Window Covering Control Features | Supports CurtainsSupports Rotation MotionSupports Up/Down MotionSupports Vertical Blinds |
Supported Meter Type | Electric Energy |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |