This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Aeotec New Generation Nano Shutter1. Used to control the motor of Curtain, support Shutter Mode and Venetian Mode .2. Can be calibrated according to diff e rent curtains3. Used to control other Z-Wave device directly.4. Support S2, more safe and more re liable5. Support SmartStart, faster inclusion
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Used for some commands auto sending when status changed. |
2 | 5 | Retransmit when receiving the follow commands |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Used to set Switch type of External Switch 1,and reports will return automatically during identify. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Unidentified mode when no identify is set, and indicate identify fails when in identify. |
1 | 2-state switch mode |
2 | 3 way switch mode |
3 | Push Button mode |
4 | Enter automatic identification mode(The blue led will fast blink) |
Used to set Switch type of External Switch 1,and reports will return automatically during identify. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Unidentified mode when no identify is set, and indicate identify fails when in identify. |
1 | 2-state switch mode |
2 | 3 way switch mode |
3 | Push Button mode |
4 | Enter automatic identification mode(The blue led will fast blink) |
Setting the Motor Behavior After Power ON. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Stay the same position before power off last time |
1 | Moves to 99% |
2 | Moves to 0% |
Note:1.Motor will stop when receiving this command in moving;2.This configuration will not change after network exclusion or ConfigurationReset. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Shutter mode / Venetian mode :Out 1= Up moving/ Multilevel switch = 99%, Out 2= Down moving/ Multilevel switch = 0% |
1 | Shutter mode : Out 1= Down moving/ Multilevel switch = 0%, Out 2= Up moving/ Multilevel switch = 99%. Venetian mode :Out 1= Up moving/ Multilevel switch = 99%, Out 2= Down moving/ Multilevel switch = 0% |
2 | Shutter mode : Out 1= Up moving/ Multilevel switch = 99%, Out 2= Down moving/ Multilevel switch = 0% Venetian mode: Out 1= Down moving/ Multilevel switch = 0%, Out 2= Up moving/ Multilevel switch = 99%. |
3 | Shutter mode / Venetian mode : Out 1= Down moving/ Multilevel switch = 0%, Out 2= Up moving/ Multilevel switch = 99%. |
Used to Enable/Disable function of External Switch S1&S2.Note :This value can be combine, e.g. set to 3(1+2=3),means networking function and Reset function are both enable. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | Enable network function, inclusion/exclusion |
2 | Enable reset to factory default function |
Used to reset configuration parameter value to default value or reset to factory default settings.NoteParameter 0x16, 0x22, 0x23, 0x24, 0x25, 0x27, 0x28 will not reset to default value by this command. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Reset all configuration parameters to default settings |
1431655765 | reset to factory default settings and removed from the z-wave network |
This parameter is to config the blade turn time(unit = 0.01s),which works only for venetian mode.Details can be found in section 4.2 of Advanced information Product Manual.Note:For Venetian, if this value is set too large for blade turning, curtain may move upwards or downwards.Calibration need to work correctly.Or this setting will force the curtain to move up or down.This configuration will not change after network exclusion or Configuration Reset. Size: 2 Byte, Default Value: 150
Setting | Description |
---|---|
10 - 32767 | 0.1 - 327.67seconds |
Curtain Trip Time is about the run time of the curtain (unit = 0.01s). Details can be found in section 4.2 of Advanced information Product Manual.Note:For Venetian, if this value is set too large for blade turning, curtain may move upwards or downwards.Calibration need to work correctly.Or this setting will force the curtain to move up or down.This configuration will not change after network exclusion or Configuration Reset. Size: 2 Byte, Default Value: 15000
Setting | Description |
---|---|
500 - 32767 | 5 - 327.67 seconds |
Note:Product will enter the right Curtain Mode after calibration, see Configuration 0x27(39) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Set:Exit Calibration Report: Not in Calibration |
1 | Set:Enter Shutter Mode Calibration Report: In Shutter Mode Calibration |
2 | Set:Enter Venetian Mode Calibration Report: In Venetian Mode Calibration |
User confirmation for Calibration(set only) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Go to next step of calibration |
Return Calibration Status(Get or Report) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Calibration Complete |
1 | Calibration start, going to Reference Point A |
2 | Reach Reference Point A, going to Reference Point B |
3 | Reach Reference Point B, waiting for Blade turn Calibraion(Only for Venetian Mode) |
4 | Going to Reference Point C(Only for Venetian Mode) |
5 | Calibration terminated |
Set the Curtain Mode.Note:1. This Operation will enter repositioning automatically;2. This configuration will not change after network exclusion or Configuration Reset. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Shutter Mode |
1 | Venetian Mode |
Set to begin repositioning. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | Repositioning begins |
Used to Get repositioning Status. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Repositioning complete |
1 | in repositioning |
Used to enable/disable calibration lock from different ways. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable calibration |
1 | Enable Action Button/ Command Calibration |
2 | Enable Action Button/ Command/S1/S2 Calibration |
Choose which report to send when switch status change Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | No Report |
1 | Basic Report |
2 | Switch Multilevel Report |
Extern Button Mode SettingNote: when setting value to 2, we advice not to set only one external switchto push button, do remember to change the controller channel beforeoperating push button, or the curtain level will be wrong. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | S1/S2 map to Z-Wave Button |
1 | S1 = Open or Stop, S2 = Close or Stop Note:Operation will not change the curtain mode, including press and hold ,short press. |
2 | 1 When configuration 0x78/79 = 03 Press and hold S1 :blade folds to 180 Press and hold S2 Blade folds to 0 Short press S1 Blinds go downwards Short press S2 Blinds go upwards Note: The device will change its curtain mode if it does not match the current mode. 2 When Configuration 0x78/79 = others S1 = Open or Stop,S2 = Close or Stop ,operation will not change the curtain mode. |
Hardware Platform | ZM5101 |
Device Type | Window Covering - Pos/End Aware |
Network Operation | Always On Slave |
Firmware Version | HW: 141 FW: 3.01:01.03 |
Z-Wave Version | 6.81.03 |
Certification ID | ZC10-19126810 |
Z-Wave Product Id | 0x0371.0x0003.0x008D |
Color | White |
Neutral Wire Required | ok |
Window Covering Control Features | Manual CalibrationSupports Horizontal Blinds/LouversSupports Up/Down Motion |
Firmware Updatable | Updatable by Consumer by RF |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |