This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Flood Sensor is capable of both detecting leaks and floods and when the level of water gets too low in pool or tank, Flood Sensor can work with your Z-Wave network to prevent emergencies such as burst water boiler to leaking air conditioners. With Z-Wave, the scope to save money is endless.The features list:1)Z-Wave Plus certified for wide compatibility (500 serials product).2)Security 0 and Security 2 framework implemented with AES-128 encryption.3)Contains an extension water detecting probe. 4)Temperature measurement.5)Vibration sensor.6)The battery life is up to 1 year. 7)Low battery alert
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Association Group 1 is the lifeline group |
2 | 5 | 1. Basic Set.Flood Sensor will send Basic Set to associated nodes whenWater leak detected. |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Flood sensor can send BASIC SET command to nodes associated with group 2. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Flood sensor can reverse its value of BASIC SET when flooding is triggered. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Send BASIC SET VALUE = 255 to nodes associated with group 2 when flooding alarm is triggered.Send BASIC SET VALUE = 0 to nodes associated with group 2 when flooding alarm is canceled. |
1 | Send BASIC SET VALUE = 0 to nodes associated with group 2 when flooding alarm is triggered.Send BASIC SET VALUE = 255 to nodes associated with group 2 when flooding alarm is canceled. |
Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 240 | The higher the value, the long the report periodically - in hexadecimal values from 0x01 to 0xFF, or 1 to 255 if your controller allows unsigned decimal values. |
0 | Disable flooding alarm |
Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | when the value is 0, the product will not sends a vibration alarm after moving or shaking; |
1 | when the value is 1, the product will sends a vibration alarm after moving or shaking |
The temperature changes at least 1 degree Celsius before reported. Size: 1 Byte, Default Value: 240
Setting | Description |
---|---|
30 - 240 | the higher the value ,the long the report time |
The precision of the temperature value is 1.Available settings(US):-670 - 2570-67257FAvailable settings(Other):-550 - 1250-55125CDefault setting (US): 1040 (104F)Default setting (Other): 400(40C) Size: 2 Byte, Default Value: 1040
Setting | Description |
---|---|
-670 - 2570 | the larger the value , the higher the high temperature(US) |
-550 - 1250 | the larger the value , the higher the high temperature(other) |
The precision of the temperature value is 1.Available settings(US):-670 - 2570-67257FAvailable settings(Other):-550 - 1250-55125CDefault setting (US): 320 (32F)Default setting (Other): 0 (0C) Size: 2 Byte, Default Value: 320
Setting | Description |
---|---|
-670 - 2570 | the smaller the value , the lower the low temperature(US) |
-550 - 1250 | the smaller the value , the lower the low temperature(other) |
0 Disable.1 Enable. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | when the value is 0, the product will not blink LED when being triggered; |
1 | when the value is 1, the product will blink LED when being triggered |
This parameter defines a battery level as the low battery.Available settings: 10-50 (10% - 50%)Default setting: 20 (20%) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
10 - 50 | Set the trigger value for the low battery alarm |
Hardware Platform | ZM5202 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 1.01 |
Z-Wave Version | 6.71.01 |
Certification ID | ZC10-20076939 |
Z-Wave Product Id | 0x0208.0x0200.0x000F |
Firmware Updatable | Not Updatable |
Supported Notification Types | |
Color | Antique Brass |
Sensors | |
Security V2 | S2_UNAUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |