This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
PRODUCT FEATURES:- Quick and reliable motion alerts to Z-Wave hub- Accurate temperature and humidity monitoring- Lux sensor for smart light automations- Battery or Micro USB power- The latest S2 security and Z-Wave Plus chip- Supports OTA firmware updates- Built-in tamper switch for extra securitySPECIFICATIONS:- Model Number: ZSE11- Z-Wave Signal Frequency: 908.42 MHz- Power: 2 x CR123A (3 V) batteries / Micro USB- Motion Detection: up to 20 feet- Humidity Detection Range: 0100 %- Light Sensor Detection Range: 065535 lux- Operating Temperature: 32104 F- Dimensions: 2.3 x 2.3 x 2.2- Range: Up to 130 feet line of sight- Installation and Use: Indoor only
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Lifeline communication to the hub |
2 | 5 | Basic set command sent to devices in Group 2 |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Adjust motion sensitivity where 8 is the most sensitive setting. Size: 1 Byte, Default Value: 6
Setting | Description |
---|---|
0 | disable motion reports |
1 - 8 | sensitivity levels where 8 is the most sensitive |
Set motion clear time for the delay before the sensor reports no motion to the hub and associated devices after detecting the last motion activity. Size: 2 Byte, Default Value: 30
Setting | Description |
---|---|
10 - 3600 | seconds |
Decide whether the sensor should send basic set commands to Group 2 when motion is detected. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | doesn't send basic set commands |
1 | sends basic set commands |
Decide whether the sensor should send basic set on or off commands to Group 2 when motion is detected. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | send 0xFF (ON) when motion is detected and 0x00 (OFF) when motion stops |
1 | send 0x00 (OFF) when motion is detected and0xFF (ON) when motion stops |
Decide whether the sensor should send binary sensor reports when motion is detected. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | doesn't send binary sensor reports |
1 | sends binary sensor reports |
Set the reporting frequency for battery, temperature, humidity, and light level. This is the minimum interval in which the sensor will send updates to the hub even if the reporting threshold isnt met. The values entered correspond to the number of hours. Note: Frequent reports will affect battery life. Size: 2 Byte, Default Value: 4
Setting | Description |
---|---|
1 - 744 | hours |
Choose if you'd like the sensor to report temperature in Celsius or Fahrenheit scale. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
1 | Celsius |
2 | Fahrenheit |
Set the battery reporting threshold (measured in percentage). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | doesn't report battery based on the reporting threshold |
1 - 99 | battery percentage |
Set the reporting threshold for temperature.The sensor will report new temperature value to the hub whenever temperature changes by the number of degrees entered as value. Size: 2 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 144 | degrees Fahrenheit |
Set the reporting threshold for humidity. The sensor will report new humidity value to the hub whenever humidity changes by the percentage number entered as value. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 | disable humidity reporting based on environmental changes |
1 - 80 | percentage |
Set the reporting threshold for lux. The sensor will report new lux value to the hub whenever the brightness level changes by the number of lux entered as value. Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 | disable lux reporting based on environmental changes |
1 - 30000 | lux |
Enable or disable LED indicator for motion alerts. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | dont flash LED when motion is detected |
1 | flash LED indicator when motion is detected |
Choose at which percentage level the sensor should send a low-battery alert to the hub. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
10 - 50 | battery level percentage |
Hardware Platform | ZM5101 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 1.04 |
Z-Wave Version | 6.51.09 |
Certification ID | ZC10-21047020 |
Z-Wave Product Id | 0x027A.0x0201.0x0006 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |