This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Danalock supports:- S0/S2 Z-Wave Security- Bluetooth Smart - Twist Assist- Auto-Lock- Hold And Release- End to End
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Z-Wave Plus Lifeline Device Reset Locally: triggered upon reset. Battery/notification: triggered upon low battery. Door Lock operation report: triggered upon a change in door lock Notification: triggered upon a change in door lock |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Helps you to lock and unlock your door lock.
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disabled |
1 | Enabled |
After a unlock operation the lock holds the lock, so the door can be opened
Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 - 2147483647 | Enable no. of seconds |
The lock will run the motor until it hits resistance.
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
The BLE is enabled for a number of seconds.
Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 2147483647 | Enable no. of seconds |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | BLE Always disabled |
1 | BLE Always enabled |
Lock after an unlock. The value is the delay in time before the lock is locked again.
Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Diable |
1 - 2147483647 | Enable no. of seconds |
Hardware Platform | ZM5202 |
Device Type | Door Lock - Keypad |
Network Operation | Listening Sleeping Slave |
Firmware Version | HW: 2 FW: 1.03:00.10 |
Z-Wave Version | 6.71.03 |
Certification ID | ZC10-21117062 |
Z-Wave Product Id | 0x010E.0x0009.0x0001 |
Firmware Updatable | Updatable by Consumer by RF |
Supported Notification Types | Access Control |
Security V2 | S2_ACCESS_CONTROL |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |