This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Venture WISE Window Sensor is a wireless, battery powered Hall effect contact sensor,compatible with the Z-Wave Plus standard. Changing the devicesstatus will automatically send signal to the Z-Wave controller andassociated devices.Sensor can be used to trigger scenes and wherever there is a needfor information about opening or closing of doors, windows, garagedoors, etc. Opening is detected by separating the sensors body andthe magnet.In addition the Sensor is equipped with a built-in temperaturesensor.Main features of Sensor:- Compatible with any Z-Wave or Z-Wave Plus Controller,- Supports protected mode (Z-Wave network Security Mode) withAES-128 encryption,- Door/window opening detected through separation of Sensorsbody and a magnet,- Built-in temperature sensor,- Detects tampering, when detached or opened,- Easily mounted on doors, windows, garage gates and roller blinds,- Battery powered,- Visual LED indicator signaling status of the device,- 7 color variations.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | u0022Lifelineu0022 reports the device status and allows for assigning single device only (main controller by default). |
2 | 5 | On/Off is assigned to the device status - contact sensor (sends Basic Set command frames). |
3 | 5 | Tamper is assigned to the TMP switch (sends alarm command frames). |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
This parameter allows to set in what state is door window when the magnet is close to the sensor. 0 - closed when magnet near1 - opened when magnet near Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | closed when magnet near |
1 | opened when magnet near |
Parameter defines events which result in sending on/off commands to devices added to the 2nd association group.These commands are sent alternately to switch the devices on and off. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | switch after opening and closing |
1 | switch after opening (parameter 12) |
2 | switch after closing (parameter 13) |
Value sent to devices in 2nd association group when opening is detected. The value of 0 turns OFF the device, 255 turns it On. In case of associating devices allowing smooth control, values 1-99 allow to set an associated device to a specified level. Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
0 | turns OFF the associated device |
1 - 99 | sets the associated device to a specified level |
255 | turns ON the associated device |
Value sent to devices in 2nd association group when closing is detected. The value of 0 turns OFF the device, 255 turns it On. In case of associating devices allowing smooth control, values 1-99 allow to set an associated device to a specified level. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | turns OFF the device |
1 - 99 | sets the associated device to a specified level |
255 | turns ON the device |
Time that must elapse from opening to send the command frame to to devices in 2nd association group. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 32400 | time in seconds |
Time that must elapse from closing to send the command frame to devices in 2nd association group. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 32400 | time in seconds |
This parameter defines events indicated by the visual LED indicator. Disabling events might extend battery life.1 - indication of opening-closing status change2 - indication of wake up (1 x click or periodical)4 - indication of device tampering NOTEParameter 2 values may be combined, e.g. 1+2=3 means that in -dications for opening/closing and waking up are enabled. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | no indication |
1 | indication of opening/closing status change |
4 | indication of device tampering |
6 | indication of wake up (1 x click or periodical) and indication of device tampering |
7 | indication of indication of opening/closing status change, wake up (1 x click or periodical) and indication of device tampering |
This parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network Security Mode. It does not apply to 1st group Lifeline. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 | none of the groups sent as secure |
1 | 2nd group On-Off sent as secure |
2 | 3rd group Tamper sent as secure |
3 | 2nd and 3rd group sent as secure |
Time period after which a tamper alarm will be cancelled. Size: 2 Byte, Default Value: 5
Setting | Description |
---|---|
0 - 32400 | time in seconds |
Reporting cancellation of tamper alarm to the controller and 3rd association group. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | do not send tamper cancellation report |
1 | send tamper cancellation report |
This parameter defines how often the temperature will be measured.The shorter the time, the more frequently the temperature will be measured, but the battery life will shorten. Size: 2 Byte, Default Value: 300
Setting | Description |
---|---|
0 | temperature measurements disabled |
5 - 32400 | time in seconds |
This parameter defines the change of temperature in comparison with last reported, resulting in temperature report being sent to the main controller.NOTEParameter 51 is active only if parameter 50 is not set to 0. Temperature measurement is performed before sending any report (regardless of parameter no. 50).Excessive reporting can affect battery lifetime. Reporting on the basis of temperaturechange (parameterno. 51) is recommended. Size: 2 Byte, Default Value: 10
Setting | Description |
---|---|
0 | temperature reports based on threshold disabled |
1 - 300 | temperature threshold (0.1 C - 30 C, 0.1 C step) |
This parameter determines how often the temperature reports will be sent to the main controller (regardless of parameters 50 and 51). Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | periodic temperature reports disabled |
300 - 32400 | time in seconds |
The value to be added to the actual temperature, measured by the sensor (temperature compensation). Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
-1000 - 1000 | (-100100 C, 0.1 C step) |
Temperature alarms reported to the Z-Wave controller. Thresholds are set in parameters 55 and 56. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | temperature alarms disabled |
1 | high temperature alarm |
2 | low temperature alarm |
3 | high and low temperature alarms enabled |
If temperature is higher than set value, overheat notification will be sent and high temperature scene will be triggered (if activated). Size: 2 Byte, Default Value: 350
Setting | Description |
---|---|
1 - 600 | (0.1 - 60 C, 0.1 C step) |
If temperature is lower than the set value, underheat notification will be sent and low temperature scene will be triggered (if activated). Size: 2 Byte, Default Value: 100
Setting | Description |
---|---|
0 - 599 | (0 - 59.9 C, 0.1 C step) |
Hardware Platform | ZM5101 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 2 FW: 3.02 |
Z-Wave Version | 6.51.09 |
Certification ID | ZC10-22127118 |
Z-Wave Product Id | 0x010F.0x0702.0x1000 |
Supported Notification Types | Access ControlHeat AlarmHome SecurityPower Management |
Sensors | Air Temperature |
Firmware Updatable | Updatable by Consumer by RF |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |