This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Custos WWD (Wireless Water Detector) Is the smallest Z-Wave compact wireless water detector with 4 sides water detection capabilities plus integrated port for remote water sensor probe as secondary physical/logical detector, innovative design allows it to work on all orientations without worrying accidental flip, incorporated high energy density lithium battery for up to X years of battery operation life span.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifeline Group- Device Reset Locally Notification- Sensor Binary Report- Indicator Report- Sensor Multilevel ReportTemperature Temperature level change auto report will be sent after wakeup every time based on Configuration Parameter 0x31 Setting.- Battery Report- Heat Alarm Notification Report (0x04)- 0x00 = State idle- 0x02 = Overheatno location support -- 0x06 = Underheatno location support- Water Alarm Notification Report (0x05)- 0x00 = State idle- 0x02 = Water leak detectedno location support- Power Management Notification (0x08)- 0x00 = State Idle- 0x11 = Battery Fluid is low |
2 | 5 | - Basic Set- 0x00 = IDEL / CANCEL (Based on Configuration Parameter 0x41 Setting)- 0xFF = TRIGGERED (Based on Configuration Parameter 0x40 Setting)-0x00 = Let the water run through (Based on Configuration Parameter 0x13)-0xFF = Doesnt let the water run through. (Based on Configuration Parameter 0x12)- 0x00 = Let the water run through (Based on Configuration Parameter 0x13)- 0xFF = Doesnt let the water run through. (Based on Configuration Parameter 0x12) |
3 | 5 | - Basic Set- 0x00 = IDEL / CANCEL (Based on Configuration Parameter 0x43 Setting)- 0xFF = TRIGGERED (Based on Configuration Parameter 0x42 Setting)-0xFF = TRIGGERED (Based on Configuration Parameter 0x31 Setting) |
4 | 5 | - Basic Set- 0x00 = IDEL / CANCEL (Based on Configuration Parameter 0x45 Setting)- 0xFF = TRIGGERED (Based on Configuration Parameter 0x44 Setting) |
5 | 5 | - Basic Set- 0x00 = IDEL / CANCEL (Based on Configuration Parameter 0x47 Setting)- 0xFF = TRIGGERED (Based on Configuration Parameter 0x46 Setting) |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Sensors Function Enable / Disable Size: 1 Byte, Default Value: 15
Setting | Description |
---|---|
0 | Built-in Water Detection Probe *(Default Enabled) |
1 - 0 | Remote Water Detection Probe *(Default Enabled) |
2 - 0 | Overheat Detection *(Default Enabled) |
3 - 0 | Freeze Detection *(Default Enabled) |
Water Leak Probe Cancellation Report Set Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Send Basic SET when Water Alarm Cancelled Either Built-in or Remote Water Detection Probe |
1 - 0 | Send Basic SET when Water Alarm Cancelled Built-in And Remote Water Detection Probe |
Battery Level Change Value to auto report Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 | Disable Battery Level Change Auto Report |
1 - 63 | Auto report when wake up every time. *(Default 0x0A = 10%) |
Battery Lower Threshold Level Report Size: 1 Byte, Default Value: 30
Setting | Description |
---|---|
1 - 99 | Battery Lower Threshold Valve Report *(Default 30%) |
Configure Temperature Report Unit Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | Disable Temperature Report |
1 - 0 | Report Celsius C unit |
2 - 0 | Report Fahrenheit F unit |
Temperature Level Change to auto report Size: 2 Byte, Default Value: 260
Setting | Description |
---|---|
0 - 255 | From 0C to 255C |
256 - 511 | From 0F to 255F |
Temperature Value Offset Report Set Size: 2 Byte, Default Value: 256
Setting | Description |
---|---|
0 - 255 | From 0C to 255C |
4096 - 4351 | From -1C to -255C |
256 - 511 | From 0F to 255F |
4353 - 4607 | From -1F to -255F |
Overheat Trigger Value SET Size: 2 Byte, Default Value: 360
Setting | Description |
---|---|
0 - 255 | From 0C to 255C |
256 - 511 | From 0F to 255F |
Overheat Cancellation Value auto report Size: 2 Byte, Default Value: 342
Setting | Description |
---|---|
0 - 255 | From 0C to 255C |
256 - 511 | From 0F to 255F |
Configure Freeze Trigger Report value Size: 2 Byte, Default Value: 360
Setting | Description |
---|---|
0 - 255 | From 0C to 255C |
256 - 511 | From 0F to 255F |
Configure Freeze Recover Report Value Size: 2 Byte, Default Value: 342
Setting | Description |
---|---|
0 - 255 | From 0C to 255C |
256 - 511 | From 0F to 255F |
Built-in Water Leak Trigger Basic SET Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable Basic Set (Send nothing) |
1 - 0 | Basic Set ON (0xFF) |
2 - 0 | Basic Set OFF (0x00) |
Built-in Water Leak Cancellation Basic SET Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable Basic Set (Send nothing) |
1 - 0 | Basic Set ON (0xFF) |
2 - 0 | Basic Set OFF (0x00) |
Remote Water Leak Trigger Basic SET Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable Basic Set (Send nothing) |
1 - 0 | Basic Set ON (0xFF) |
2 - 0 | Basic Set OFF (0x00) |
Remote Water Leak Cancellation Basic SET Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable Basic Set (Send nothing) |
1 - 0 | Basic Set ON (0xFF) |
2 - 0 | Basic Set OFF (0x00) |
Overheat Trigger Value Basic SET Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable Basic Set (Send nothing) |
1 - 0 | Basic Set ON (0xFF) |
2 - 0 | Basic Set OFF (0x00) |
Overheat Recover Value Basic SET Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable Basic Set (Send nothing) |
1 - 0 | Basic Set ON (0xFF) |
2 - 0 | Basic Set OFF (0x00) |
Freeze Trigger Value Basic SET Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable Basic Set (Send nothing) |
1 - 0 | Basic Set ON (0xFF) |
2 - 0 | Basic Set OFF (0x00) |
Freeze Recover Value Basic SET Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable Basic Set (Send nothing) |
1 - 0 | Basic Set ON (0xFF) |
2 - 0 | Basic Set OFF (0x00) |
Resend Water Leak Notification Time Set Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Do not resend |
1 - 30 | 1 - 30 Minutes |
Buzzer Related Function Actions Set Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 | Buzzer Enable responds with GSensor in action *(Default 1 = Eanbled) |
1 - 0 | Buzzer Enable responds with Water Leak Detection *(Default 1 = Enabled) |
Sound works first 3S Water Leak Detected Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable Saving mode (Buzzer sound works during whole Water Leak is detected) |
1 - 0 | Enable Saving mode (Buzzer function only works 3s when Water Leak is detected) |
Hardware Platform | ZGM130 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 2.00 |
Z-Wave Version | 7.14.3 |
Certification ID | ZC12-21010160 |
Z-Wave Product Id | 0x0270.0x0201.0x010B |
Outdoor Use | ok |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |