Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
FEATURES:- Powerful dry contact NO/NC relays to control loads up to 20 A for NO- Perfect for DC motors, pumps, commercial gates, or HVAC equipment- Control up to 2 connected loads independently or together- Z-Wave or optional wall switch control (toggle or momentary type)- Monitor inputs independently from output control- Built-in timers for each relay to simplify automation- Built-in Z-Wave Plus signal repeater to extend network range- Powered by 12-24 V DC/AC or USB C port for easy set-up- Wall mounting and minimal design for clean installation- NEW 700 Z-Wave chip, S2 security, and SmartStartSPECS:- Model Number: ZEN17- Z-Wave Signal Frequency: 908.42 MHz- Power: 12-24 V DC/AC or USB C (DONT use laptop / tablet chargers)- Maximum Load: NO relays: 20 A, NC relays: 10 A- Inputs: dry contact or 12-24 V AC/DC (use 1 input type at a time!)- Range: Up to 200 feet line of sight- Operating Temperature: 32-104 F (0-40 C)- Installation and Use: Indoor only
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Lifeline communication to the hub |
2 | 5 | Basic set for devices associated with relay 1 |
3 | 5 | Basic set for devices associated with relay 2 |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Set the on off status for the relays after power failure. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | ALL relays forced to OFF (regardless of state prior to power outage) |
1 | ALL relays remember and restore on/off status after power failure (default) |
2 | ALL relays forced to ON (regardless of state prior to power outage) |
3 | Relay 1 remembers and restores on/off status after power failure, Relay 2 forced to ON |
4 | Relay 2 remembers and restores on/off status after power failure, Relay 1 forced to ON. |
Choose if youd like the connected input (switch) on S1 C / VC C to trigger the load connected to R1 or if you want to use the input reports for monitoring only and separate theoutput from the input. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | input trigger disabled |
1 | input trigger enabled (default) |
Choose if youd like the connected input (switch) on S2 C / VC C to trigger the load connected to R2 or if you want to use the input reports for monitoring only and separate the output from the input. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | input trigger disabled |
1 | input trigger enabled (default) |
Choose between seconds, minutes, and hours as the unit for the auto turnoff timer for Relay 1. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | minutes |
1 | seconds |
2 | hours |
Choose between seconds, minutes, and hours as the unit for the auto turn on timer for Relay 1. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | minutes |
1 | seconds |
2 | hours |
Choose between seconds, minutes, and hours as the unit for the auto turn off timer for Relay 2. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | minutes |
1 | seconds |
2 | hours |
Choose between seconds, minutes, and hours as the unit for the auto turn on timer for Relay 2. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | minutes |
1 | seconds |
2 | hours |
Choose the wall switch or input type you want to connect to the S1 C terminals.Press and hold the Z-Wave button for 5 seconds to change to garage mode manually.IMPORTANT: If you set this parameter to value 4-10, youll need to exclude and re-include the device (without changing any settings) so that a child device is created for the input of your choice! Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | momentary for lights only |
1 | toggle switch (light on when the switch is toggled up, light off when the switch is toggled down); |
2 | toggle switch (state changes whenever the switch is toggled) |
3 | garage door (momentary mode for Z-Wave control) |
4 | leak alarm (water sensor) |
5 | heat alarm |
6 | motion alert |
7 | open/close alert (door sensor) |
8 | CO alarm |
9 | CO2 alarm |
10 | on/off report (dry contact switch/sensor) |
Sync R1 and R2 together to prevent them from being activated at the same time. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | DC motor mode disabled (relays will activate whenever they're triggered) |
1 | DC motor mode enabled (relay will check the status of the other relay aer being triggered and will shut the other relay off before activating so that only one of the relays is on at the same time) |
Choose the wall switch or input type you want to connect to the S2 C terminals.Click twice, holding the Z-Wave button for 5 seconds the second time to change to garage mode manually. IMPORTANT: If you set this parameter to value 4-10, youll need to exclude and re-include the device (without changing any settings) so that a child device is created for the input of your choice! Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | momentary for lights only |
1 | toggle switch (light on when the switch is toggled up, light off when the switch is toggled down) |
2 | toggle switch (state changes whenever the switch is toggled) |
3 | garage door (momentary mode for Z-Wave control) |
4 | leak alarm (water sensor) |
5 | heat alarm |
6 | motion alert |
7 | open/close alert (door sensor) |
8 | CO alarm |
9 | CO2 alarm |
10 | on/off report (dry contact switch/sensor) |
Choose if you want the LED indicator to turn on when any of the relays are on or if all of them are off, or if you want it to remain on or off at all times. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | LED indicator is on when ALL of the relays are off, LED indicator is off when any of the relays is on (default); |
1 | LED indicator is on when any of the relays is on, LED indicator is off when ALL of the relays are off; |
2 | LED indicator is always OFF; |
3 | LED indicator is always ON |
Use this parameter to set the time after which you want the device connected to Relay 1 to automatically turn off once it has been turned on. The number entered as valuecorresponds to the number of minutes, seconds, or hours (set the unit in Par. 15). Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | disabled |
1 - 65535 | minutes/seconds/hours |
Use this parameter to set the time after which you want the device connected to Relay 1 to automatically turn on once it has been turned off. The number entered as valuecorresponds to the number of minutes, seconds, or hours (set the unit in Par. 16). Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | disabled |
1 - 65535 | minutes/seconds/hours |
Use this parameter to set the time after which you want the device connected to Relay 2 to automatically turn off once it has been turned on. The number entered as value corresponds to the number of minutes, seconds, or hours (set the unit in Par. 17). Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | disabled |
1 - 65535 | minutes/seconds/hours |
Use this parameter to set the time after which you want the device connected to Relay 2 to automatically turn on once it has been turned off. The number entered as value corresponds to the number of minutes, seconds, or hours (set the unit in Par. 18). Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | disabled |
1 - 65535 | minutes/seconds/hours |
Hardware Platform | ZGM130 |
Device Type | Binary Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.00 |
Z-Wave Version | 7.13.6 |
Certification ID | ZC12-21030204 |
Z-Wave Product Id | 0x027A.0xBB00.0xBB0A |
Firmware Updatable | Updatable by Consumer by RF |
Color | Gray |
Switch Type | Dry Contact |
Electric Load Type | FluorescentIncandescentInductive (e.g. Motor)LEDMLV (Magnetic) |
Loads Controlled | 2 |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |