This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
The IQ Smart Dimmer can be used to turn any outlet into a smart outlet to turn lamps On, Off, or control dimming of any lamps with dimmable light bulbs. Each Z-Wavedevice also serves as a repeater in the Z-Wave network, extending and improving the mesh network in the installed location.The IQ Smart Dimmer is a Z-Wave Pluscertified device and includes S2 security and SmartStart. You can now add this device securely and with ease using QR code on the box or device.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Lifeline. QZ2142-840 will trigger AUTO report function if the Switch status had been changed. |
2 | 5 | When the output of the QZ2142-840 is changed, On (0xFF) or Off (0x00). The QZ2142-840 will automatically send out a related basic set command On (0xFF) or Off (0x00) to its associated group. |
3 | 5 | When the output of the QZ2142-840 is changed, On (0xFF) or Off (0x00). The QZ2142-840 will automatically send out a related basic set command On (0xFF) or Off (0x00) to its associated group. |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Multilevel minimumvalue can be setLocal Button> this should apply to both for local or Z-Wave operationParameter=10Size=1Value=0disableValue=1..Value=99 Default = 1 Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disabled |
1 - 99 | Minimum multilevel level |
Multilevel maximumvalue can be setLocal Button> this should apply to both for local or Z-Wave operationParameter=11Size=1Value=0disableValue=1..Value=100- NOT ACCEPTED BY HUBDefault = 99 Size: 1 Byte, Default Value: 99
Setting | Description |
---|---|
0 | Disabled |
1 - 100 | Maximum multilevel level |
Double Tap Behavior: when switch is off and quickly press UPPER paddle 2 times, switch turns on to x brightnessLocal Button Parameter=12Size=1Value = 0enable double tap to full brightness (99)Value = 1 custom value set in parameter 18 Value = 2 enable double tap to maximum brightness (turn on to the value relate with parameter 11) Value = 3 disable double tap to full brightnessDefault = 0 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Double tap goes to full brightness |
1 | Double tap goes to custom value in Parameter 18 |
2 | Double tap goes to maximum brightness based on Parameter 11 |
3 | Disable double tap to full brightness |
Enable or Disable local / Z-Wave control Parameter=15Size=1Value=0 disable (when paddle pressed switch will not turn light on or off BUT it will still control the light via z-wave and it will change LED indicator status and on/off/multilevel status when paddle is pressed)Value=1 enable (normal operation like now)Value = 2 disable local and Z-Wave control (LED and on/off status will still change if paddle pressed) >> make sure that status is still reported and LED indicator changes when Z-Wave control is disabledDefault = 1 Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable local control |
1 | Enable local Z-Wave control |
2 | Disable local and Z-Wave Control |
dimmer speed (only for local press & hold): amount of seconds it takes to go from 0 to 100% brightness when pressing and holding the paddleParameter=16Size=1,Value=1from 0x63 to 0x00 or from 0x00 to 0x63 need 1sValue=2 from 0x63 to 0x00 or from 0x00 to 0x63 need 2s ..Value=99 from 0x63 to 0x00 or from 0x00 to 0x63 need 99sDefault = 5 Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 99 | Dimming speed in seconds |
Custom brightness level - in this parameter define default brightness level the switch will turn on to from main switch or regular switch in 3-way when pressed upper paddle once.Parameter: 18Size: 1 byte decValues 0-990 - last brightness level1-99 custom brightness leveldefault = 0 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Last brightness level |
1 - 99 | Custom brightness level |
3-way switch typeParameter=19,Size=1,Value=0 toggle switch(device changes status when switch changes status,it can only turn on or turn off lamp,it cant dimmer)(default);Value = 1toggle switch(press 1x change device status;quickly press 2x the result dependonPar11/Par12; quickly Press 3x it trigger dimmer in loop(dimmer up/dimmer down )Value=2 momentary switch (press 1x change device status;quickly press 2x the result dependonPar11/Par12;holdtrigger dimmer in loop(dimmer up/dimmer down )Value=3 momentary switch (press 1x change device status;quickly press 2x the result dependonPar11/Par12;holdtrigger dimmer in loop(dimmer up/dimmer downBUT after double click to full brightness, hold will dim DOWN always instead of trying to increase brightness) >> This value is missing, please add to settingNotice: when the value=1,or value=2,the switch cant respond immediately,because it need to recognize multiplepress. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | toggle switch(device changes status when switch changes status, it can only turn on or turn off lamp |
1 | toggle switch(press 1x change device status; quickly press 2x the result dependonParameter 11 and 12 |
2 | momentary switch (press 1x change device status; quickly press 2x the result dependonPar11 and 12 |
3 | momentary switch (press 1x change device status; quickly press 2x the result dependonPar11 and Par12 |
Parameter=2Size=1Value=0 On when Off and Off when OnValue=1On when On and Off when OffValue=2Always OffValue=3Always OnDefault =0 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Output and the LED are in the different state. |
1 | Output and the LED are in the same state. |
2 | LEDAlways OFF |
3 | LEDAlways ON |
Association reportsParameter=20,Size=1Values:0Z-WavecontrolMultilevelreport (withouteachlevel,justfinallevel)Manualcontrol (shortpress):Basicreport(withouteachlevel,justfinallevel)Manualcontrol(longpress & relayenable):Basicreport(withouteachlevel,justfinallevel)Manualcontrol(longpress &relaydisable):Multilevelreport (eachlevelwillbereported) 1Z-WavecontrolMultilevelreport (withouteachlevel,justfinallevel)Manualcontrol (shortpress):Basicreport (withouteachlevel,justfinallevel)Manualcontrol(longpress & relayenable OR disable):Basicreport (withouteachlevel,justfinallevel)2Z-WavecontrolMultilevelreport (withouteachlevel, justfinallevel)Manualcontrol (shortpress): Multilevel report (withouteachlevel, justfinallevel)Manualcontrol (longpress & relayenable):Multilevelreport (withouteachlevel, justfinallevel)Manualcontrol (longpress &relaydisable):Multilevelreport (eachlevelwillbereported)default = 2 Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | Z-WavecontrolMultilevelreport (withouteachlevel,justfinallevel) Manualcontrol (shortpress):Basicreport(withouteachlevel,justfinallevel) Manualcontrol(longpress & relayenable):Basicreport(withouteachlevel,justfinallevel) Manualcontrol(longpress &relaydisable):Multilevelreport (eachlevelwillbereported) |
1 | Z-WavecontrolMultilevelreport (withouteachlevel,justfinallevel) Manualcontrol (shortpress):Basicreport (withouteachlevel,justfinallevel) Manualcontrol(longpress & relayenable OR disable):Basicreport (withouteachlevel,justfinallevel) |
2 | Z-WavecontrolMultilevelreport (withouteachlevel, justfinallevel) Manualcontrol (shortpress): Multilevel report (withouteachlevel, justfinallevel) Manualcontrol (longpress & relayenable):Multilevelreport (withouteachlevel, justfinallevel) Manualcontrol (longpress &relaydisable):Multilevelreport (eachlevelwillbereported) |
Disabled Relay BehaviorParameter=21,Size=1Value=0 report on/off and multilevelstatus when paddle is pressed and change LED indicatorstatus and Parameter 15 is set to value 0 or 2 (output control disabled) according to setting in Parameter 20.Value=1 DONt report on/off or multilevel status or and change LED indicator status when paddle is pressed and Parameter 15 is set to value 0 or 2 (output control disabled). Default = 0 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | report on/off and multilevelstatus when paddle is pressed and change LED indicatorstatus and Parameter 15 is set to value 0 or 2 (output control disabled) according to setting in Parameter 20. |
1 | DONt report on/off or multilevel status or and change LED indicator status when paddle is pressed and Parameter 15 is set to value 0 or 2 (output control disabled). |
Night Mode Brightness LevelSet the level of brightness the dimmer will turn on to when off and lower paddle held DOWN for 2 seconds.Parameter=22,Size=1Values: 0- disable function; 1-99 %Default:: 20 Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
0 | Disabled |
1 - 99 | Brightness level |
LED Indicator ColorParameter=23Size=1Value=0 WhiteValue=1BlueValue=2GreenValue=3RedDefault = 1 Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | White |
1 | Blue |
2 | Green |
3 | Red |
LED Indicator BrightnessParameter=24Size=1Value=0 Bright (100%)Value=1Medium (60%)Value=2Low (30%)Default =1 Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | Medium (60%) |
2 | Low (30%) |
0 | Bright (100%) |
Single Tap Behavior: when switch is off and press UPPER paddle 1 time, switch turns on to x brightnessLocal Button Parameter=25Size=1Value = 0last brightness level Value = 1 custom value set in parameter 18 Value = 2 maximum brightness set in parameter 11 Value = 3 full 100% brightnessDefault = 0 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | last brightness level |
1 | custom value set in parameter 18 |
2 | maximum brightness set in parameter 11 |
3 | full 100% brightness |
Auto Turn-Off Timer--- Values: 065535 (minutes) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Default |
1 - 65535 | 165535 (minutes) |
Auto Turn-On Timer Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Default |
1 - 65535 | 165535 (minutes) |
Restores state after power failureParameter=8Size=1Value=0 output offValue=1 output onValue=2out put the state after powerDefault =2 Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | Output OFF |
1 | Output ON |
2 | The state before a power outage |
Ramp rateLocal Button + Z-Wave> change to local and Z-Wave like in the latest ZEN30 firmware, also applies to any multilevel changes (so there should be soft transition between 20 and 80% brightness if changed from the hub for example)Parameter=9Size=1,Value=1from 0x63 to 0x00 or from 0x00 to 0x63 need 1sValue=2 from 0x63 to 0x00 or from 0x00 to 0x63 need 2s ..Value=99 from 0x63 to 0x00 or from 0x00 to 0x63 need 99sDefault = 1 Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 99 | Ramp rate in seconds |
Hardware Platform | ZGM130 |
Device Type | Multilevel Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.00 |
Z-Wave Version | 7.13.6 |
Certification ID | ZC12-22040337 |
Z-Wave Product Id | 0x012A.0xFF00.0xFF0D |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |