This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
The Ness Z-Wave Single Button (ZWSB) is a simple Z-Wave scene controller that allows you to control devices through the Z-Wave network and run various scenes defined in your Z-Wave gateways.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | |
2 | 5 | |
3 | 5 |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
This parameter defines how the Basic Set commands send to the nodes listed in 2nd association group after a Key Pressed 1 time scene event has triggered. 0 - No Basic Set commands send; 1 - Basic Set ON/OFF alternately; 2 - Basic Set ON with delay off; 3 - Basic Set OFF. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 |
The period of time in seconds to send Basic Set OFF command to Association Group 2 after BASIC Set ON command has reported. This parameter take affected only the option 2 has been selected in Configuration Parameter 1. 10 - disable BASIC Set OFF report; Time in seconds to send BASIC Set OFF command. Size: 2 Byte, Default Value: 10
Setting | Description |
---|---|
0 | 0 |
This parameter defines the duration that the key need to be pressed and held down to trigger the Key Held Down Scene event. The value is in seconds. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | 0 |
This parameter defines how the Start Level Change/the Stop Level Change commands send to the nodes listed in 3rd association group. 0 - No any Start Level Change and Stop Level Change commands send; 1 - Send the Start Level Change/the Stop Level Change commands when the Key Held Down/the Key Released scene event has triggered; 2 - Send Start Level Change command when the Key Held Down. It does not sent the Stop Level Change command when the Key Released. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 |
This parameter defines the duration in Switch Multilevel Start Level Change command. The value is in second. 0 - Instantly transition from the current value to the new target value; 1 ~ 120 - The time transition should take from the current value to the new target value. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | 0 |
Report battery low warning message when battery level reaches this value in percentage. Range: 10~50 (10%~50%); The battery level range: 100% - 3V; 0% - 1.8V. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 | 0 |
The battery level scheduled report interval time is based on every 30 minutes per kick. The value N related to the time in minutes is N x 30 minutes. Range: 0~120. Default: 12 (12x30 =360 minutes). Value = 0 - Disable Battery level scheduled report. Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
0 | 0 |
Hardware Platform | ZGM130S037HGN2 / ZGM130S037HGN1 |
Device Type | Central Scene DT |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 01 FW: 01.01 |
Z-Wave Version | 7.16.3 |
Certification ID | ZC14-22090132 |
Z-Wave Product Id | 0x0189.0x0204.0x0601 |
Color | |
Switch Type | |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |