Quickstart

This is a secure Window Covering DT for . To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.

This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.

If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.

Product Description

META WIRED MOTOR CONTROLLER7 is an "in wall device", for the multilevel control of roller shutter motors. It can accurately control the opening and closing of blinds, curtains, shutters, venetian blinds as requested by the user through local commands or remotely.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association - one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.

Association Groups:

Group Number Maximum Nodes Description
1 8
2 8
3 8

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.

IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.

Parameter 2: ON_FAVORITE_LEVEL

The On level reached when the Up Button received a double click. Valid value range:50-99
Size: 1 Byte, Default Value: 80

Setting Description
0 0

Parameter 20: CALIBRATION_COMPLETE

Define if the device has been calibrated. (0: not calibrated, 1:calibrated)
Size: 1 Byte, Default Value: 0

Setting Description
0 0

Parameter 21: MAX_LEVEL_TIME

Time in thousandth of a seconds to reach the full open position. Valid value range 100-100.000
Size: 4 Byte, Default Value: 100

Setting Description
0 0

Parameter 22: MIN_LEVEL_TIME

Time in thousandth of a seconds to reach the full close position. Valid value range 100-100.000
Size: 4 Byte, Default Value: 100

Setting Description
0 0

Parameter 23: INVERTION_TIMEOUT

Time in thousandth of a second after which the movement direction can be changed. Valid value range 500-3.000
Size: 4 Byte, Default Value: 500

Setting Description
0 0

Parameter 24: LIMIT_SWITCH_TIMEOUT

Time in thousandth of a second for recognizing that the limit switch has been reached. Valid value range 1000-5.000
Size: 4 Byte, Default Value: 2500

Setting Description
0 0

Parameter 25: FINE_CALIBRATION

Adjustment in Percentage value of the 50% position after the initial calibration. Valid value range 50-150
Size: 1 Byte, Default Value: 100

Setting Description
0 0

Parameter 3: OFF_FAVORITE_LEVEL

The Off level reached when the Down Button received a double click. Valid value range 0-49
Size: 1 Byte, Default Value: 20

Setting Description
0 0

Parameter 37: REPORT_FREQUENCY

Time in seconds after which the new position report is sent if the target position is not reached.
Size: 1 Byte, Default Value: 5

Setting Description
0 0

Parameter 38: SEND_MULTILEVEL_REPORT

Define if the Multilevel Report will be sent unsolicited. (0: report is not sent, 1: report is sent)
Size: 1 Byte, Default Value: 0

Setting Description
0 0

Parameter 61: INVERT_MOVEMENT

Can be used to invert the motor direction. (0: not inverted, 1:inverted)
Size: 1 Byte, Default Value: 0

Setting Description
0 0

Technical Data

Hardware Platform ZGM130S037HGN2 / ZGM130S037HGN1
Device Type Window Covering DT
Network Operation Always On Slave
Firmware Version HW: 01 FW: 02.01
Z-Wave Version 7.16.3
Certification ID ZC14-22120172
Z-Wave Product Id 0x0149.0x0004.0x000d
Security V2 S2_UNAUTHENTICATED ,S2_AUTHENTICATED
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Application Status
  • Association Grp Info V3
  • Association V2
  • Basic V2
  • Configuration V4
  • Device Reset Locally
  • Firmware Update Md V5
  • Indicator V3
  • Manufacturer Specific V2
  • Multi Channel Association V3
  • Switch Multilevel V4
  • Powerlevel
  • Security 2
  • Supervision
  • Transport Service V2
  • Version V3
  • Window Covering
  • Zwaveplus Info V2

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways,Remote Controls or battery operated wall controllers.
  • Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators and even remote controls.
  • Primary Controller — is the central organizer of the network. It must be a controller. There can be only one primary controller in a Z-Wave network.
  • Inclusion — is the process of adding new Z-Wave devices into a network.
  • Exclusion — is the process of removing Z-Wave devices from the network.
  • Association — is a control relationship between a controlling device and a controlled device.
  • Wakeup Notification — is a special wireless message issued by a Z-Wave device to announces that is able to communicate.
  • Node Information Frame — is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.