This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Manual or Z-Wave control of DC motors (reversed polarity).
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | |
2 | 5 | |
3 | 5 | |
4 | 5 |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Restores state after power failure Size: 1 Byte, Default Value: 100
Setting | Description |
---|---|
0 | 0 |
Auto turn-on timer Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Auto turn-off timer Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Auto turn-on/off timer units Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Enable or Disable Output control Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 |
External switch type for S1 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
External switch type for S2 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Association Reports Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 |
Set repositioning begins Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Enable stop signal Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 |
Led indicator load status Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 |
Motor moving time(Shutter mode) Size: 2 Byte, Default Value: 6000
Setting | Description |
---|---|
0 | 0 |
Blade Turn Time (Venetian mode) Size: 2 Byte, Default Value: 1000
Setting | Description |
---|---|
0 | 0 |
Moving time Calibration Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Curtain working mode Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 |
External Switch control Way Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Enable External Switch Pair Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 |
Inverts the orientation of Motor Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Hardware Platform | ZGM130S037HGN2 / ZGM130S037HGN1 |
Device Type | Window Covering DT |
Network Operation | Always On Slave |
Firmware Version | HW: 01 FW: 01.10 |
Z-Wave Version | 7.16.3 |
Certification ID | ZC14-23090329 |
Z-Wave Product Id | 0x027A.0x0904.0x0219 |
Firmware Updatable | |
Z-Wave Scene Type | |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |