This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Heatit Z-TRM6 DC is an electronic thermostat with a potential free relay, designed for boiler control or actuators. The thermostat can be controlled through your Z-Wave network or via the buttons on the front. The thermostat has a user friendly interface.Heatit Z-TRM6 DC has 3 modes; Heat - Cool and Eco.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 0 | |
2 | 10 | |
3 | 10 | |
4 | 10 |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Disable or enable local control Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Manually calibrate the Internal sensor Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Manually calibrate the Floor sensor Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Manually calibrate the External sensor Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Select regulation mode Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Select degrees for regulation hysteresis Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 | 0 |
Decide what is shown during standby Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Set brightness during active state Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 | 0 |
Set brightness during standby state Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 | 0 |
Set temperature report interval Size: 2 Byte, Default Value: 840
Setting | Description |
---|---|
0 | 0 |
Set temperature report hysteresis in C Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 | 0 |
Select sensor mode of the device. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 |
Time to turn on regulation after error Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Set the setpoint for heating mode Size: 2 Byte, Default Value: 210
Setting | Description |
---|---|
0 | 0 |
Set the setpoint for Cooling mode Size: 2 Byte, Default Value: 180
Setting | Description |
---|---|
0 | 0 |
Set the setpoint for ECO mode Size: 2 Byte, Default Value: 180
Setting | Description |
---|---|
0 | 0 |
Set thermostat state update interval Size: 2 Byte, Default Value: 43200
Setting | Description |
---|---|
0 | 0 |
Changes operating mode Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 |
Enable or disable OWD Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Set the size of load Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Decide if output should be inverted Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Valve exercise period Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Select resistance of the connected NTC Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Set minimum setpoint for Internal sensor Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 | 0 |
Set minimum setpoint for Floor sensor Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 | 0 |
Set minimum setpoint for External sensor Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 | 0 |
Set maximum setpoint for Internal sensor Size: 2 Byte, Default Value: 400
Setting | Description |
---|---|
0 | 0 |
Set maximum setpoint for Floor sensor Size: 2 Byte, Default Value: 400
Setting | Description |
---|---|
0 | 0 |
Set maximum setpoint for External sensor Size: 2 Byte, Default Value: 400
Setting | Description |
---|---|
0 | 0 |
Hardware Platform | EFR32ZG23A |
Device Type | Thermostat DT |
Network Operation | Always On End Node |
Firmware Version | HW: 01 FW: 01.00:02.07 |
Z-Wave Version | 7.18.1 |
Certification ID | ZC14-23120376 |
Z-Wave Product Id | 0x019B.0x0032.0x3201 |
IP (Ingress Protection) Rated | ok |
Thermostat Power Source | Mains powered (120V/240V) |
Thermostat Modes | CoolEnergy Save Heat |
Neutral Wire Required | ok |
Color | White |
Firmware Updatable | Updatable by Consumer by RF |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |