This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Aeotec TriSensor 8
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | |
2 | 5 | |
3 | 5 | |
4 | 5 | |
5 | 5 | |
6 | 5 | |
7 | 5 |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Over Heat Group Threshold Size: 2 Byte, Default Value: 806
Setting | Description |
---|---|
0 | 0 |
Under Heat Group Threshold Size: 2 Byte, Default Value: 600
Setting | Description |
---|---|
0 | 0 |
Over Light Group Threshold Size: 2 Byte, Default Value: 2000
Setting | Description |
---|---|
0 | 0 |
Under Light Group Threshold Size: 2 Byte, Default Value: 100
Setting | Description |
---|---|
0 | 0 |
Low Battery Threshold Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
0 | 0 |
Threshold Check Enable/Disable Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Temperature Threshold Size: 1 Byte, Default Value: 30
Setting | Description |
---|---|
0 | 0 |
Lux Threshold Size: 2 Byte, Default Value: 250
Setting | Description |
---|---|
0 | 0 |
Threshold Check Time Size: 2 Byte, Default Value: 900
Setting | Description |
---|---|
0 | 0 |
Sensor Limit Control Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Temperature Upper Limit Size: 2 Byte, Default Value: 824
Setting | Description |
---|---|
0 | 0 |
Temperature Lower Limit Size: 2 Byte, Default Value: 320
Setting | Description |
---|---|
0 | 0 |
Lux Upper Limit Size: 2 Byte, Default Value: 1000
Setting | Description |
---|---|
0 | 0 |
Set lux lower limit level Size: 2 Byte, Default Value: 100
Setting | Description |
---|---|
0 | 0 |
Temperature Scale Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 |
Automatic Interval Time Size: 2 Byte, Default Value: 3600
Setting | Description |
---|---|
0 | 0 |
Motion Untrigger Time Size: 2 Byte, Default Value: 60
Setting | Description |
---|---|
0 | 0 |
Motion Sensitivity Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | 0 |
Motion Group Control Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Motion Group Value Setting Size: 2 Byte, Default Value: 65280
Setting | Description |
---|---|
0 | 0 |
Motion Group Control Requirement Size: 2 Byte, Default Value: 30000
Setting | Description |
---|---|
0 | 0 |
Hardware Platform | EFR32ZG23A |
Device Type | Notification Sensor DT |
Network Operation | Reporting Sleeping End Node |
Firmware Version | HW: 01 FW: 02.06 |
Z-Wave Version | 7.18.3 |
Certification ID | ZC14-24010383 |
Z-Wave Product Id | 0x0371.0x0102.0x002D |
Color | |
Firmware Updatable | |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |