This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Use the Z-Wave shut-off valve actuator to shut your main water valve automatically when a leak is detected.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | |
2 | 5 | |
3 | 5 | |
4 | 5 | |
5 | 5 |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Motor Full Close Offset (%) Size: 1 Byte, Default Value: 4
Setting | Description |
---|---|
0 | 0 |
Battery Threshold To Auto Report Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 | 0 |
Low Battery Level to Report Size: 1 Byte, Default Value: 30
Setting | Description |
---|---|
0 | 0 |
Water Valve Low Battery Control Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 |
Inverse Switch Binary Report value Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Valve SET Value when receives 0xFF Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 |
Valve SET Value when receives 0x00 Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | 0 |
Configure reporting temperature unit Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | 0 |
Temperature Threshold to auto report Size: 2 Byte, Default Value: 260
Setting | Description |
---|---|
0 | 0 |
Configure Temperature Report Offset Size: 2 Byte, Default Value: 256
Setting | Description |
---|---|
0 | 0 |
Configure Overheat Trigger Report Value Size: 2 Byte, Default Value: 360
Setting | Description |
---|---|
0 | 0 |
Configure overheat recover report value Size: 2 Byte, Default Value: 342
Setting | Description |
---|---|
0 | 0 |
Overheat trigger SET value Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Overheat cancellation SET value Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Configure Freeze Trigger Report Value Size: 2 Byte, Default Value: 288
Setting | Description |
---|---|
0 | 0 |
Configure Freeze Recover Report Value Size: 2 Byte, Default Value: 292
Setting | Description |
---|---|
0 | 0 |
Configure Valve Control during freeze Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 |
Configure freeze trigger SET value Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Freeze cancellation SET value Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Auto Report Time in Mins Size: 1 Byte, Default Value: 15
Setting | Description |
---|---|
0 | 0 |
Water Leak Trigger SET value Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 |
Water Leak Cancellation SET value Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Enable / Disable Water Leak Valve Control Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 |
Report When No Longer Trigger Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 | 0 |
Disable/Enable Buzzer Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 |
Configure LED brightness level Size: 1 Byte, Default Value: 80
Setting | Description |
---|---|
0 | 0 |
Disable / Enable Touch Keylock Protection Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Disable / Enable Water Valve Report Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 |
Disable / Enable Overheat Report Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Disable / Enable Freeze Report Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 |
Disable / Enable Water Leak Report Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 |
Disable / Enable AC Power Report Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 |
Disable / Enable Battery Report Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 |
Motor Auto Control Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 | 0 |
Motor Auto Control Day Size: 1 Byte, Default Value: 14
Setting | Description |
---|---|
0 | 0 |
Motor Full Open Offset (%) Size: 1 Byte, Default Value: 9
Setting | Description |
---|---|
0 | 0 |
Hardware Platform | ZGM130S037HGN2 / ZGM130S037HGN1 |
Device Type | Binary Switch DT |
Network Operation | Always On End Node |
Firmware Version | HW: 04 FW: 02.00 |
Z-Wave Version | 7.18.8 |
Certification ID | ZC14-24070455 |
Z-Wave Product Id | 0x027A.0x0101.0x0036 |
Outdoor Use | ok |
Color | |
Firmware Updatable | |
IP (Ingress Protection) Rated | ok |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |