This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Kwikset 10 key touchpad long range connected electronic deadbolt
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
CP1 is r/w parameter with 1byte.Set on status LED show the status of the latch every 6sec.Set off status not be shown Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 |
CP10 is r/w parameter with a 1byte.When read return handing of lock.When written run handing operation.Report 0=!success-0=fail Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 |
CP2 is r/w parameter with 1byte.Set on buzzer is enabled,will sound in normal events.Set off buzzer is disabled,sound won't occur Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 |
CP3 is r/w parameter with 1byte.Set on program button is available for user code maintenance.Set off program button isn't available Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 |
CP4 is r/w parameter with 1byte.Control the secure screen functionality on touch locks only.Parameter isn't used on non-touch locks Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 |
CP40 is write parameter with 1byte.Used to request the lock to perform a factory reset back to its default state Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
CP46 is read parameter with 4byte.Used to retrieve the calculated sideload value from the last motor run it was performed Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Hardware Platform | ZGM130S037HGN2 / ZGM130S037HGN1 |
Device Type | Lock DT |
Network Operation | Listening Sleeping End Node |
Firmware Version | HW: 01 FW: 10.20:69.35 |
Z-Wave Version | 7.20.2 |
Certification ID | ZC14-24080463 |
Z-Wave Product Id | 0x0090.0x0811.0x23A9 |
Door Lock Type | Deadbolt |
Security V2 | S2_ACCESS_CONTROL |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |