This is a
SmartStart Learn Mode:
1. SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity.
2. Indicator Light will become flash white light for 1s indicating the product has been powered, and then become flash blue light indicating SmartStart Learn Mode starts.
3.It will become constantly bright yellow light after being assigned a NodeID.
4. If Adding succeeds, it will bright blue light for 2s and become Load Indicator Mode.
5. If Adding fails, it will bright red light for 2s and turn back to breathing blue light and then start SmartStart Learn Mode again.
Note: The label of QR Code on the product and package are used for SmartStart Inclusion.
The Z-Wave DSK Code is at bottom of the package. Please do not remove or damage them.
The Aeotec Smart Switch 7 is an elegant appearance, small size, easy to use, Smart Plug. This supports power metering function, with high measurement accuracy, and more accurate knowledge of the power consumption of the load, over-current, over-load and over-heat protection, which is more secure and reliable, scene personalization and is more intelligent, Night Light Mode to reduce light pollution, S2 Security, which is safer and more reliable and SmartStart, making inclusion more convenient.
Button Presses and LED reaction.
Button Press | Function when released. | LED Reaction |
Power On | (Unpaired from the network). (Paired into the network). |
Breathes blue. LED follows the state of load (configurable). |
QR Code Scan | Pairs into Z-Wave network. | Blue fast blink during pairing, then solid blue for 2 seconds to indicate success. |
Tap or Click | Controls load state. |
LED Follows load control state. |
Press 2 times slowly | Enters pair mode. | Blue fast blink, after first Click Red and after second Click Orange. The LED change to Green, if the device paired |
Press 2 times fastly | Enters unpair mode | After press 2 times the led indicate purple. After inclusion, the LED flashes Blue |
Press 3 times | Disable the Alarm Response | LED stops flash |
Press and hold for 2 to 5 seconds. | Toggles LED display mode when SS7 is paired. | Yellow LED
|
Press and hold for 5 to 10 seconds. | Test communication quality | Indicator Light will become cyan light when press, and quickly flash cyan light when release, indicating start to test communication quality between the product and Node 1.
At the end of the test, Indicator Light will display the colour according to the communication quality.
Good = green light for 2s. General = yellow light for 2s. Poor = red light for 2s. |
Press and hold for 10 to 15 seconds. | Reset overload alarm and over current Alarm | Red LED flashes |
Press and hold for 15 to 20 seconds. | Stay in Z-Wave network, but factory resets all settings back to default. | Red LED Flashes faster. |
Press and hold for 20 seconds and more. | Completely factory reset and remove from Z-Wave network. | Breathes Blu |
Reset to factory default | If not, plug it into a wall socket and power on. To complete the reset process manually, press and hold the Action Button for at least 15s and then release. The LED indicator will become breathing blue light, which indicates the reset operation is successful. Otherwise, please try again. |
Inclusion | 1. Plug the device into a power outlet.
2. Press the button on the device once to cancel the Smartstart mode.
3. Press the button on the device again. |
Exclusion | 1. Plug the device into a power outlet. 2. Press Action Button 2 times quickly. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline. |
2 | 5 | Retransmit a Basic Set, Binary Switch Set or Scene Activation Set to the nodes associated. |
Define a threshold power and automatically turn off switch when the load connected bypasses the maximum allowed power regardless of always on setting.Over-load protection will be active if the load power exceeds the setting and lasts for more than 30s. If be active, Indicator Light will become red light blinking and the product will send out Notification Report (Over-load detected), and disable the function that manually or RF control the switch state until users set Protection State to be unprotected through the Gateway or Controller. Even power off will still keep Protection State. Size: 2 Byte, Default Value: 2415
Setting | Description |
---|---|
0 | Disable over-load protection |
1 - 2415 | Threshold power is 1-2145W |
Enabled by (Alarm Settings), and determines what the switch does in the case an alarm is triggered.When receives any alarm enabled by Alarm Settings, Indicator Light will keep blinking based on Parameter 0x12 (18). It will prohibit user from manually or RF control the switch state until the alarm is disable. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable, no reaction to alarm settings |
1 | Switch is ON |
2 | Switch is OFF |
3 | Switch will turn ON in 5 seconds, and then turn OFF in 5 seconds in a cycle until user disables the alarm manually |
Determine if alarms are enabled in Switch, and what Switch will react to which alarm. The format of the parameter is Bit field (Checkboxes). The parameter MUST be treated as a bit field where each individual bit can be set or reset. A graphical configuration tool SHOULD present this parameter as a series of checkboxes. Please refer to the manual for more details about supported Notification Type and Notification Event. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Access Control trigger state |
256 | Smoke Alarm |
512 | CO Alarm |
1024 | CO2 Alarm |
2048 | Heart Alarm |
4096 | Water Alarm |
8192 | Access Control |
16384 | Home Security |
Determines the method of disabling the alarm of the device.Note:Power off will also disable the alarm response without any limitation. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Can be disabled by 3x tapping Action Button within 1 second |
1 | Can be disabled when receives a State Idle corresponding to the alarm. Note: If Access Control is enable, it also can be disabled when receives the reversal state of window/door. |
10 - 255 | Sets the duration of the alarm in seconds(i.e. Customer sets this setting to 50, the alarm state of the Switch will disable after 50 seconds) |
When receiving the enable Alarm, it will flash according to the blink frequency configured by this parameter until the Alarm is disable. Brightness level and color is based on current indicator. If the value of brightness level and color is 0, it will flash based on last visible color. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
1 - 9 | Set amount of blinks per seconds. |
The parameter can be used to test the effect of LED blinking. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Stop blinking. |
1 - 255 | Set the duration and start the blinking process. * This sets the timeframe of blinking in seconds. * Once the duration ends, the blinking will stop. |
Action in case of power out. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Last status |
1 | Switch is on |
2 | Switch is off |
Configure what command will be sent via Lifeline when switch state has changed. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | None |
1 | Basic Report |
2 | Binary Switch Report |
Note: Configuring brightness and color of Indicator Light in different time/status of different modes will be saved in the current setting mode. Please refer to the manual for more details. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | Disable Mode |
1 | Night Light Mode |
2 | ON/OFF Mode |
If you want to set Night Light Mode to be enable at 19:00 at night and disable at 07:30 in the morning, you just need to configure:Value1=0x13, Value2=0x00, Value3=0x07, Value4=0x1E. Size: 4 Byte, Default Value: 301991936
Setting | Description |
---|---|
0 - 2147483647 | Value1=Enable Hour, Value2=Enable Minute, Value3=Disable Hour, Value4=Disabale Minute |
Threshold Power (W) for inducing automatic report. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 - 2300 | 1-2300W |
Threshold Power Consumption (kWh) for inducing automatic report. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 - 10000 | 1-10000kWh |
Threshold Current (A) for inducing automatic report. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 - 100 | 0.1-10A. Unit is 0.1A. |
The format of the parameter is Bit field (Checkboxes). The parameter MUST be treated as a bit field where each individual bit can be set or reset. A graphical configuration tool SHOULD present this parameter as a series of checkboxes.Note:The sending frequency is related to Configuration Parameter 0x6F (111). Size: 4 Byte, Default Value: 15
Setting | Description |
---|---|
1 | Power Consumption |
2 | Power |
4 | Voltage |
8 | Current |
Configure the sending frequency of Meter Report. Size: 4 Byte, Default Value: 600
Setting | Description |
---|---|
0 | Disable |
600 - 2592000 | 600-2592000s. (10minute-30day) |
Factory Reset or Initialization (Write Only) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1431655765 | Factory Reset: Restore the product to factory settings and remove from the network. |
0 | Initialization: Initialize all configuration parameters to default values. |
Dimensions | 42 x 42 x 70 mm |
Weight | 56 gr |
Hardware Platform | ZM5101 |
EAN | 1220000016415 |
IP Class | IP 20 |
Voltage | 230 V |
Load | 10A |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Z-Wave Version | 6.81.03 |
Certification ID | ZC10-19066544 |
Z-Wave Product Id | 0x0371.0x0003.0x00AF |
Outdoor Use | ok |
Sensors | CurrentPowerVoltage |
Supported Notification Types | Power ManagementSystem |
Z-Wave Scene Type | Scene |
Color | White |
Firmware Updatable | Updatable by Consumer by RF |
Supported Meter Type | Electric Energy |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |