This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Aeotec MultiSensor 7 was developed to detect ambient values and movement and to transmit them with Z-Wave Plus. It is powered by Aeotec’s Gen7 technology. You can find out more about MultiSensor 7 by following that link.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Press and hold the button for 20 seconds. When the red led flashes, the device will enter the factory reset mode.
The product contains batteries. Please remove the batteries when the device is not used. Do not mix batteries of different charging level or different brands.
Determine the power type you want to use.
MultiSensor 7 can be a sleeping battery device or a repeater as a USB-powered device. Make sure you select your preferred power type before you start pairing.
Note - Any time you change the input power type (ie. Battery to USB power), you should re-include as your Z-Wave hub will only understand if it is a sleeping device or a Repeater device upon its first pair into your controller.
For a USB powered installation (acts as a repeater when paired on USB power):
1. Remove the battery cover by sliding the Unlock button LEFT, then pull the cover off.
2. Insert the MicroUSB of the provided USB cable into your sensor‘s MicroUSB port.
3. Insert the larger end of the USB cable into a computer or any 5V adapter which will immediately power your MultiSensor 7.
4. Make sure to seat the Battery Cover back onto the MultiSensor 7 and lock it in by sliding the Unlock button RIGHT.
For a battery-powered installation (acts as a sleeping device when paired on battery power):
1. Remove the battery cover by sliding the Unlock button LEFT, then pull the cover off.
2. Insert two CR123A lithium batteries orientated according to the diagram within your sensor.
Try inserting the batteries flat rather than at an angle.
Note: MultiSensor 7 can be powered by a single CR123A (doesn‘t matter which port), though batteries will require changing more frequently (half the expected battery life).
WARNING: Not compatible with rechargeable CR123A batteries (3.6V).
3. Make sure to seat the Battery Cover back onto the MultiSensor 7 and lock it in by sliding the Unlock button RIGHT.
To install your TriSensor with the Back-Mount Plate;
1. You can affix the Back-Mount Arm by Double-Sided Tape or using the provided KA2.5ƒ-20 mm screws.
Tips: We suggest you choose the second method (using screws to affix the Back-Mount Arm) which would be more stable.
2. After you have completed the affixing of Back-Mount Arm, you will need to lock TriSensor to the Back-Mount Arm by screwing TriSensor in.
3. The Back-Mount Arm may be locked at various angles by turning the Friction Lock clockwise and counter-clockwise to respectively tighten or loosen the angle of the arm. You can rotate the Friction Lock to change the measurement area of sensor.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Button Functions.
Action button press | LED Status | Function |
1x Tap (when factory reset) | Solid Yellow | Pair Mode Enters Z-Wave pair mode, flashes white/green 4 times within 2 seconds upon success. |
1x Tap (when already paired) | Solid Purple | Sends NIF / Excludes device if Z-Wave controller is in unpair mode, starts blue LED fade in/out if unpaired and factory reset successfully. |
Press and hold [1, 2 seconds) | No LED | N/A |
Press and hold [2, 5 seconds) | Solid Red | Quick Wakeup LED will disappear as soon as you release its button. The MultiSensor 7 will send a wakeup report to your Z-Wave Controller to take in any queued z-wave commands waiting in your controller. |
Press and hold [5, 9 seconds) | Solid Orange | Long Wakeup Mode LED will remain solid Orange upon release of its button for 5 minutes maximum (or until told to sleep by user or z-wave controller). This will allow you to easily configure this device while the sensor is used with battery power assuming your Z-Wave controller does not queue the command. |
Press and hold [9, 15 seconds) | Solid Cyan | Communication Health Test (Direct gateway communication - does not test through repeaters). This will test your MultiSensor 7 direct communication to your Z-Wave Controller. It will remain Cyan while it is testing. Once finished it will become a solid color for 2 seconds as red, yellow, or green to indicate health: Red = Bad health, can‘t communicate at all. Yellow = Moderate health, could use improvement, some communcation missed. Green = Great health |
Press and hold [15, 20 seconds) | Blinking Red | Release here to cancel Factory Reset. |
Press and hold [20+ seconds) | Blue fade in/out for 2 seconds. | Factory Reset. |
This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In order to communicate with the device, a static controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time is significantly decreased.
This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbox. Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static controller this controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the device. To wakeup the device please perform the following action:
In order to configure Multisensor 7, you must either (1) wake up Multisensor 7 using the below button press function, or (2) temporarily put your Multisensor 7 on USB power.
This section will go over the manual wakeup of this sensor in case you don‘t want to wait for configuration.
Quick Wakeup.
1. Press and hold Multisensor 7 Action button
2. Wait until the LED turns into a Red Color (1 - 2 seconds)
3. Release Multisensor 7 Action Button, the LED should turn off right away. Any queued commands in your Z-Wave Controller will be sent over.
Long Wakeup.
1. Press and hold Multisensor 7 Action button
2. Wait until the LED turns into a solid orange color (2 - 5 seconds)
3. Release Multisensor 7 Action Button, the LED should remain solid orange while it is awake. Send any configurations from your hub (assuming the commands are not queued).
4. Tap the Action Button on Multisensor 7 to put Multisensor 7 back to sleep, or wait 5 minutes. (recommended to manually put it back to sleep to conserve battery life).
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifeline |
2 | 5 | Basic Set Command will be sent to the associated device when motion trigger or untrigger. The basic set value is determined by Param11, Param12. See Param13 for more information. |
3 | 5 | Basic Set: When the temperature change value is over or under the threshold set by Param16. Scale is determined by Param64. |
4 | 5 | Basic Set: When the temperature change value is under or over the threshold set by Param17. Scale is determined by Param64. |
5 | 5 | Basic Set: When the current humidity is over or under the threshold set by Param14 |
6 | 5 | Basic Set: When the current humidity is under or over the threshold set by Param15 |
7 | 5 | Basic Set: When the current light/lux is over or under the threshold set by Param18 |
8 | 5 | Basic Set: When the current light/lux is under or over the threshold set by Param19. |
9 | 5 | Basic Set: When the current UV is over or under the threshold set by Param20 |
10 | 5 | Basic Set: When the current UV is under or over the threshold set by Param21 |
11 | 5 | Sensor Multilevel Report: When sensors above over limit or below under limit. |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Used to enable/disable beaming.If set to 1, FLiRs commands will be supported. But the device must be re-included into the network to activate it. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Presence re-detection time set in second to allow motion sensor to reset timeout of motion sensor. In this time, the motion sensor can not be triggered again. If this value reach zero, the timeout configuration value set by Param3 will be reset. This setting value must always be less than timeout configuration.0 - disable1~3600 - timeout set in seconds Size: 2 Byte, Default Value: 30
Setting | Description |
---|---|
30 - 3600 | timeout set in seconds |
Timeout configuration set in second for motion sensor to send no trigger status. Size: 2 Byte, Default Value: 240
Setting | Description |
---|---|
30 - 3600 | timeout set in seconds |
Set the sensitivity of motion sensor. Size: 1 Byte, Default Value: 11
Setting | Description |
---|---|
0 | Disable |
1 - 11 | sensitivity range |
Set which command class will be sent when the motion sensor is triggered or detriggered. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | Sends Notification Report |
1 | Sends Sensor Binary Report |
2 | Sends Notification and Sensor Binary Report |
Used to enable/disable vibration sensor. Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 | disable vibration |
1 - 254 | timeout set in minutes to reset vibration status |
255 | timeout set in minutes to reset vibration status |
Used to enable/disable vibration intensity reports. If set to 1, vibration intensity will be sent to gateway when triggered. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Timeout set in seconds after Wakeup CC is send out before go to sleep. If wakeup no more information received, return to sleep mode immediately. Size: 1 Byte, Default Value: 15
Setting | Description |
---|---|
0 - 255 | Timeout set in seconds |
This value is Readonly. Used to report the power status (USB or Battery powered) The device must be re-included in the network to change the role type. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | When battery powered, the device will act as RSS. |
1 | When USB cable insert, the device will act as LSS. |
Set control of other devices on group2 based on motion trigger. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Send BASIC_SET (0xFF) when motion is triggered to associated device Send BASIC_SET (0x00) when motion is untriggered to associated device |
1 | Send BASIC_SET (0x00) when motion is triggered Send BASIC_SET (0xFF) when motion is untriggered |
2 | Send BASIC_SET (0xFF) when motion is triggered, Nothing when motion untriggered. |
3 | Send BASIC_SET (0x00) when motion is triggered, Nothing when motion untriggered. |
4 | Send BASIC_SET (0x00) when motion is untriggered, Nothing when motion triggered. |
5 | Send BASIC_SET (0xFF) when motion is untriggered, Nothing when motion triggered. |
6 | Send BASIC_SET (value is configured by parameter 12) when motion is triggered to associated devices. Send BASIC_SET (value is configured by parameter 12) when motion is untriggered. |
Set Basic Set value for Group2. The MSB will act as the basic set value when motion trigger. The LSB will act as the basic set value when motion untrigger. E.g. value=0x0A00, then BASIC_SET(0x0A) will be sent when motion trigger, BASIC_SET(0x00) will be sent when motion untrigger. Size: 2 Byte, Default Value: 65280
Setting | Description |
---|---|
0 - 65535 | Set Basic Set value for Group2. |
Set threshold of Light/Lux when devices associated in group2 should be triggered by motion. Associated device only receive BASIC_SET command when light Size: 2 Byte, Default Value: 30000
Setting | Description |
---|---|
0 - 30000 | Set threshold of Light/Lux |
Set threshold of humidity. If measured humidity >= (this value), send BASIC_SET (0xFF) to associated devices through group5. If measured humidity < (this value) send BASIC_SET (0x00) to associated devices through group5. Size: 1 Byte, Default Value: 60
Setting | Description |
---|---|
0 - 100 | Set threshold of humidity. |
Set threshold of humidity. If measure humidity(this value) send BASIC_SET (0x00) to associated devices through group6. Size: 1 Byte, Default Value: 40
Setting | Description |
---|---|
0 - 100 | Set threshold of humidity. |
Set threshold of temperature. Designed to control Air Conditioners or temperature controllers ON or OFF. If measured temperature >= (this value, Scale is determined by Param64) send BASIC_SET (0xFF) to associated devices. If measured temperature<(this value) send BASIC_SET (0x00) to associated devices. E.g. Value 239 means 23.9 C. Value 750 means 75.0 F. Size: 2 Byte, Default Value: 239
Setting | Description |
---|---|
-400 - 850 | Set threshold of temperature |
Set threshold of temperature. Designed to control Air Conditioners or temperature controllers ON or OFF. If measured temperature(this value) send BASIC_SET (0x00) to associated devices. E.g. Value 155 means 15.5 C. Value 600 means 60.0 F. Size: 2 Byte, Default Value: 155
Setting | Description |
---|---|
-400 - 850 | Set threshold of temperature |
Set threshold of Light/Lux. If measured light/lux >= (this value) send BASIC_SET (0xFF) to associated devices. If measured light/lux < (this value) send BASIC_SET (0x00) to associated devices. Size: 2 Byte, Default Value: 2000
Setting | Description |
---|---|
0 - 30000 | Set threshold of Light/Lux. |
Set threshold of Light/Lux. If measured light/lux(this value) send BASIC_SET (0x00) to associated devices. Size: 2 Byte, Default Value: 100
Setting | Description |
---|---|
0 - 30000 | Set threshold of Light/Lux. |
Set threshold of UV. If measured UV >= (this value) send BASIC_SET (0xFF) to associated devices. If measured UV < (this value) send BASIC_SET (0x00) to associated devices. Size: 1 Byte, Default Value: 8
Setting | Description |
---|---|
0 | Set threshold of UV. |
Set threshold of UV. If measured UV(this value) send BASIC_SET (0x00 to associated devices.) Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 11 | Set threshold of UV. |
Configure low battery report threshold, sends low battery report via notification and battery report when battery level drops under setting. Unit %. Size: 1 Byte, Default Value: 50
Setting | Description |
---|---|
10 - 90 | Configure low battery report threshold |
Enable/Disable threshold reporting, check time can be adjusted by Param45. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | disable all threshold reports |
1 | enable all threshold reports |
Threshold = (Value * 0.1) Scale is determined by Param64. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 255 | Threshold = (Value * 0.1) Scale is determined by Param64. 0 = disable. |
Humidity range = 1% to 50%, Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 - 50 | Humidity range = 1% to 50%, 0 = disable. |
Size: 2 Byte, Default Value: 250
Setting | Description |
---|---|
0 - 10000 | Lux Threshold 0 = disabled |
Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 11 | UV Threshold 0 = disabled |
Set threshold check time in seconds if the threshold is enabled via Parameter 40. Size: 2 Byte, Default Value: 240
Setting | Description |
---|---|
1 - 65535 | Set threshold check time in seconds when USB powered |
60 - 65535 | Set theshould check time in secons when Battery powered |
Enable/Disable alarm report for low temperature Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Used to enable/disable measurement reports for various sensors that is more than the upper limit value or less than the lower limit value. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Temperature upper level |
2 | Humidity upper level |
4 | Lux upper level |
8 | UV upper level |
16 | Temperature lower level |
32 | Humidity lower level |
64 | Lux lower level |
128 | UV lower level |
Set upper limit level for temperature set in scale of 0.1. Scale is determined by Param64. If (Current measurement) > (Upper Limit), then report sensor. Size: 2 Byte, Default Value: 280
Setting | Description |
---|---|
-400 - 1000 | Set upper limit level for temperature |
Set lower limit level for temperature set in scale of 0.1. Scale is determined by Param64. If (Current Measurement) < (Lower limit), then report sensor. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
-400 - 1000 | Set lower limit level for temperature |
Temperature recover limit set in scale of 0.1. Scale is determined by Param64. If (Current measurement) = (lower limit + recover limit), then temperature report. Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
1 - 255 | Temperature recover limit set in scale of 0.1. |
Set humidity upper limit level. Size: 1 Byte, Default Value: 60
Setting | Description |
---|---|
0 - 100 | Set humidity upper limit level. |
Set humidity lower limit level Size: 1 Byte, Default Value: 40
Setting | Description |
---|---|
0 - 100 | Set humidity lower limit level |
Set humidity recover limit level. Refer to Param 51. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 50 | Set humidity recover limit level |
Set lux upper limit level. Size: 2 Byte, Default Value: 1000
Setting | Description |
---|---|
0 - 30000 | Set lux upper limit level. |
Set lux recover limit level. Refer to Param 51. Size: 1 Byte, Default Value: 100
Setting | Description |
---|---|
1 - 255 | Set lux recover limit level. |
Set UV upper limit level. Size: 1 Byte, Default Value: 8
Setting | Description |
---|---|
1 - 11 | Set UV upper limit level. |
Set UV lower limit level. Size: 1 Byte, Default Value: 4
Setting | Description |
---|---|
1 - 11 | Set UV lower limit level. |
Set UV recover limit level. Refer to Param 51. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 5 | Set UV recover limit level. |
This is read only and bit mask. Out of the limit state of sensors. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | within limit |
1 | Temperature upper level |
2 | Humidity upper level |
4 | Lux upper level |
8 | UV upper level |
16 | Temperature lower level |
32 | Humidity lower level |
64 | Lux lower level |
128 | UV lower level |
Set the scale for temperature when reports. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Celsius |
1 | Fahrenheit |
Allow user to enable/disable LED activity of specific reports sent by sensor. Button press indicator is not affected by this. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | disable |
1 | enable |
If LED is enabled by Param81, allow user to change the report color of motion sensor. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 | Disable |
1 | Red |
2 | Blue |
3 | Green |
4 | Pink |
5 | Cyan |
6 | Purple |
7 | Orange |
8 | Yellow |
9 | White |
If LED is enabled by Param81, allow user to change the report color of temperature sensor. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Red |
2 | Blue |
3 | Green |
4 | Pink |
5 | Cyan |
6 | Purple |
7 | Orange |
8 | Yellow |
9 | White |
If LED is enabled by Param81, allow user to change the report color of humidity sensor. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Red |
2 | Blue |
3 | Green |
4 | Pink |
5 | Cyan |
6 | Purple |
7 | Orange |
8 | Yellow |
9 | White |
If LED is enabled by Param81, allow user to change the report color of Lux sensor. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Red |
2 | Blue |
3 | Green |
4 | Pink |
5 | Cyan |
6 | Purple |
7 | Orange |
8 | Yellow |
9 | White |
If LED is enabled by Param81, allow user to change the report color of UV sensor.0 - Disabled1 - Red2 - Blue3 - Green4 - Pink5 - Cyan6 - Purple7 - Orange8 - Yellow9 - White Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Red |
2 | Blue |
3 | Green |
4 | Pink |
5 | Cyan |
6 | Purple |
7 | Orange |
8 | Yellow |
9 | White |
If LED is enabled by Param81, allow user to change the report color of vibration sensor. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | Disable |
1 | Red |
2 | Blue |
3 | Green |
4 | Pink |
5 | Cyan |
6 | Purple |
7 | Orange |
8 | Yellow |
9 | White |
If LED is enabled by Param81, allow user to change the report color of battery. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Red |
2 | Blue |
3 | Green |
4 | Pink |
5 | Cyan |
6 | Purple |
7 | Orange |
8 | Yellow |
9 | White |
If LED is enabled by Param81, allow user to change the report color of wakeup. Size: 1 Byte, Default Value: 8
Setting | Description |
---|---|
0 | Disable |
1 | Red |
2 | Blue |
3 | Green |
4 | Pink |
5 | Cyan |
6 | Purple |
7 | Orange |
8 | Yellow |
9 | White |
If LED is enabled by Param81, allow user to change indicator color when receiving communication from gateway or other devices. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Red |
2 | Blue |
3 | Green |
4 | Pink |
5 | Cyan |
6 | Purple |
7 | Orange |
8 | Yellow |
9 | White |
Checklist 1 for automatic timed report. When the corresponding item is selected, it will be checked when timeout setting by Param111. Size: 1 Byte, Default Value: 241
Setting | Description |
---|---|
1 | Battery |
16 | UV |
32 | Temperature |
64 | Humidity |
128 | Lux |
Checklist 2 for automatic timed report. When the corresponding item is selected, it will be checked when timeout setting by Param112. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Battery |
16 | UV |
32 | Temperature |
64 | Humidity |
128 | LUX |
Checklist 3 for automatic timed report. When the corresponding item is selected, it will be checked when timeout setting by Param113. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Battery |
16 | UV |
32 | Temperature |
64 | Humidity |
128 | LUX |
Interval time set in seconds to check the checklist1s items. Multilevel Sensor Report will be sent when timeout. Size: 2 Byte, Default Value: 3600
Setting | Description |
---|---|
30 - 65535 | Interval time set in seconds |
Interval time set in seconds to check the checklist2s items. Multilevel Sensor Report will be sent when timeout. Size: 2 Byte, Default Value: 3600
Setting | Description |
---|---|
30 - 65535 | Interval time set in seconds |
Interval time set in seconds to check the checklist3s items. Multilevel Sensor Report will be sent when timeout. Size: 2 Byte, Default Value: 3600
Setting | Description |
---|---|
30 - 65535 | Interval time set in seconds |
Can add or minus this setting value to calibrate temperature when checked. Scale is defined by Param64. e.g. Value 15 means 1.5C or 1.5F. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
-200 - 200 | Temperature Offset Value |
Can add or minus this setting value to calibrate humidity when checked. Unit: %. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-100 - 100 | Humidity Offset Value |
Can add or minus this setting value to calibrate Lux when checked. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
-10000 - 10000 | Lux Offset Value |
Can add or minus this setting value to calibrate UV when checked. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-10 - 10 | Offset Value range -10-10. |
Dimensions | 45 x 45 x 40 mm |
Weight | 65 gr |
Hardware Platform | ZGM130 |
EAN | 1220000016873 |
IP Class | IP 20 |
Voltage | 3V |
Battery Type | 2 * CR123A |
Device Type | Notification Sensor |
Network Operation | Always On Slave |
Z-Wave Version | 7.12.2 |
Certification ID | ZC12-20120147 |
Z-Wave Product Id | 0x0371.0x0002.0x0018 |
Firmware Updatable | Updatable by Consumer by RF |
Color | White |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |