This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Aeotec TriSensor 8 was developed to detect ambient values and movement and to transmit them with Z-Wave Plus. It is powered by Aeotec’s Gen8 technology. You can find out more about TriSensor 8 by following that link. To see whether TriSensor 8 is known to be compatible with your Z-Wave system or not, please reference our Z-Wave gateway comparison listing. The technical specifications of TriSensor 8 can be viewed at that link.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
1. Make sure the device has been powered.
2. Press and hold the button for 12+ seconds, then release the action button.
The product contains batteries. Please remove the batteries when the device is not used. Do not mix batteries of different charging level or different brands.
Placement Considerations.
There are some placement considerations when using the TriSensor 8 as a motion sensor. Above are some diagrams that show the distance at which the wall or ceiling installations can perform based on the height TriSensor 8 is installed, as well as the angle.
The longer detection range of the motion sensor is in the direction of the side of the battery.
Installation positioning advice:
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
1. Set your Z-Wave gateway into Z-Wave unpair (exclusion) mode.
2. Tap the action button 3x times within 1.5 seconds; the red LED will light up.
Power up TriSensor 8.
TriSensor 8 can only be battery-powered, you must first power up your TriSensor before you can pair it and use it in your Z-Wave network.
Steps.
1. Remove the battery cover by sliding the Unlock button LEFT, then pull the cover off.
2. Insert 1x CR123A lithium batteries orientated according to the diagram within your sensor.
Try inserting the batteries flat rather than at an angle.
WARNING: Not compatible with rechargeable CR123A batteries (3.6V).
3. You can close up the TriSensor 8 by placing the cover back on at an angle, but I would recommend doing this once you are done pairing the sensor to your Z-Wave network. So hold of on doing this so that you can reach the Action button on the TriSensor 8.
The Node Information Frame (NIF) is the business card of a Z-Wave device. It contains information about the device type and the technical capabilities. The inclusion and exclusion of the device is confirmed by sending out a Node Information Frame. Beside this it may be needed for certain network operations to send out a Node Information Frame. To issue a NIF execute the following action: Press button 3 times.
This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In order to communicate with the device, a static controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time is significantly decreased.
This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbox. Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static controller this controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the device. To wakeup the device please perform the following action: Press and hold the button for 3 seconds.
Here are a few hints for network installation if things dont work as expected.
This device is capable of receiving a new firmware 'over the air'. The update function needs to be supported by the central controller. Once the controller starts the update process, perform the following action to confirm the firmware update: You can find OTA Update by Aeotec.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifeline |
2 | 5 | Motion (Basic Set) |
3 | 5 | Over Heat (Basic Set) |
4 | 5 | Under Heat (Basic Set) |
5 | 5 | Over light (Basic Set) |
6 | 5 | Under Light (Basic Set) |
7 | 5 | Temperature (Multisensor) |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Timeout configuration set in second for TriSensor to send no trigger status. Size: 2 Byte, Default Value: 60
Setting | Description |
---|---|
30 - 3600 | seconds |
Set the sensitivity of TriSensor. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | disable |
1 - 3 | Sensitivity |
Set control of other devices on group2 based on motion trigger Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Send BASIC_SET (0xFF) when motion is triggered to associated device Send BASIC_SET (0x00) when motion is untriggered to associated device |
1 | Send BASIC_SET (0x00) when motion is triggered Send BASIC_SET (0xFF) when motion is untriggered |
2 | Send BASIC_SET (0xFF) when motion is triggered, Nothing when motion untriggered |
3 | Send BASIC_SET (0x00) when motion is triggered, Nothing when motion untriggered. |
4 | Send BASIC_SET (0x00) when motion is untriggered, Nothing when motion triggered. |
5 | Send BASIC_SET (0xFF) when motion is untriggered, Nothing when motion triggered. |
6 | Send BASIC_SET (value is configured by parameter 8) when motion is triggered to associated devices. Send BASIC_SET (value is configured by parameter 8) when motion is untriggered. |
Set Basic Set value for Group2. The MSB will act as the basic set value when motion trigger. The LSB will act as the basic set value when motion untrigger. E.g. value=0x0A00, then BASIC_SET(0x0A) will be sent when motion trigger, BASIC_SET(0x00) will be sent when motion untrigger. Size: 2 Byte, Default Value: 65280
Setting | Description |
---|---|
0 - 30000 | Value |
Set threshold of Light/Lux when devices associated in group2 should be triggered by motion. Associated device only receive BASIC_SET command when light <= (this value). Size: 2 Byte, Default Value: 30000
Setting | Description |
---|---|
0 - 30000 | Value |
Set threshold of temperature. Designed to control Air Conditioners or temperature controllers ON or OFF. If measured temperature >= (this value, Scale is determined by Param24) send BASIC_SET (0xFF) to associated devices. If measured temperature < (this value) send BASIC_SET (0x00) to associated devices. E.g. Value 239 means 23.9 C. Value 750 means 75.0 F. Size: 2 Byte, Default Value: 270
Setting | Description |
---|---|
270 - 850 | °C |
806 - 1850 | °F |
Set threshold of temperature. Designed to control Air Conditioners or temperature controllers ON or OFF. If measured temperature <= (this value, Scale is determined by Param24) send BASIC_SET (0xFF) to associated devices. If measured temperature > (this value) send BASIC_SET (0x00) to associated devices. E.g. Value 155 means 15.5 C. Value 600 means 60.0 F Size: 2 Byte, Default Value: 155
Setting | Description |
---|---|
-100 - 155 | °C |
140 - 600 | °F |
0 | disable |
Set threshold of Light/Lux. If measured light/lux >= (this value) send BASIC_SET (0xFF) to associated devices. If measured light < (this value) send BASIC_SET (0x00) to associated devices. Size: 2 Byte, Default Value: 2000
Setting | Description |
---|---|
0 | disable |
1 - 30000 | Lux |
Set threshold of Light/Lux. If measured light/lux <= (this value) send BASIC_SET (0xFF) to associated devices. If measured light/lux > (this value) send BASIC_SET (0x00) to associated devices. Size: 2 Byte, Default Value: 100
Setting | Description |
---|---|
0 | disable |
1 - 30000 | Lux |
Configure low battery report threshold, sends low battery report via notification and battery report when battery level drops under setting. Unit %. Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
10 - 50 | % |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | disable |
1 | enable |
Size: 1 Byte, Default Value: 30
Setting | Description |
---|---|
0 | disable |
1 - 255 | Value x 0,1 |
Size: 2 Byte, Default Value: 250
Setting | Description |
---|---|
0 | disable |
0 - 10000 | Lux |
Set threshold check time in seconds. Size: 2 Byte, Default Value: 900
Setting | Description |
---|---|
60 - 65535 | Time in seconds |
This value is bit mask. Used to enable/disable measurement reports for various sensors that is more than the upper limit value or less than the lower limit value. (1+2=3) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Temperature upper level |
2 | Lux upper level |
4 | Temperature lower level |
8 | Lux lower level |
Set upper limit level for temperature set in scale of 0.1. Scale is determined by Param23. If (Current measurement) > (Upper Limit), then report sensor. Size: 2 Byte, Default Value: 280
Setting | Description |
---|---|
280 - 1000 | °C |
824 - 2120 | °F |
Set lux upper limit level. If (Current measurement) > (Upper Limit), then report sensor. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
-400 - 0 | °C |
-400 - 320 | °F |
Set Lux upper limit level. If (Current measurement) > (Upper Limit), then report sensor. Size: 2 Byte, Default Value: 1000
Setting | Description |
---|---|
0 - 30000 | Lux |
Set Lux lower limit level. If (Current Measurement) < (Lower limit), then report sensor. Size: 2 Byte, Default Value: 100
Setting | Description |
---|---|
0 - 30000 | Lux |
Set the scale for temperature when reports. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | °C |
1 | °F |
Interval time set in seconds to check the sensor report. Multilevel Sensor Report will be sent when timeout Size: 2 Byte, Default Value: 3600
Setting | Description |
---|---|
30 - 65535 | Time in seconds |
Dimensions | 45 x 45 x 40 mm |
Weight | 22 gr |
Hardware Platform | EFR32ZG23 |
EAN | 1220000017276 |
IP Class | IP 20 |
Voltage | 3V |
Battery Type | 1 * CR123A |
Device Type | Sensor |
Firmware Version | 02.07 |
Z-Wave Version | 07.12 |
Certification ID | ZC14-24010390 |
Z-Wave Product Id | 0x0371.0x0002.0x002d |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |