Quickstart

This is a secure On/Off Power Switch for Europe. To run this device please connect it to your mains power supply. 1. With the gateway application scan the QR code on the Device label and add the Security 2 (S2) Device Specific Key (DSK) to the Provisioning List in the gateway.
2. Connect the Device to a power supply.
3. Check if the blue LED is blinking in Mode 1. If so, the Device is not added to a Z-Wave™ network.
4. Adding will be initiated automatically within a few seconds after connecting the Device to a power supply, and the Device will be added to a Z-Wave™ network automatically. 
5. The blue LED will be blinking in Mode 2 during the adding process.
6. The load connected to O will be blinking 1s on/1s off/1s on/1s off if the Device is successfully added to a Z-Wave™ network.
7. The green LED will be blinking in Mode 1 if the Device is successfully added to a Z-Wave™ network.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.

This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.

If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.

Product Description

The Wave 2PM (Device) is a single product that enables remote control of two electrical devices such as bulbs, ceiling fans, and IR heaters. It switches (on/off) two independent loads and measures their power consumption separately and in total. The Device is compatible with switches (default) and push-buttons.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.

1. To enter the Setting mode, quickly press and hold the S button on the Device until the LED turns Solid blue.
2. Press the S button multiple times until the LED turns Solid red.
3. Press and hold (> 2s) S button on the Device until the red LED starts blinking in Mode 3. Releasing the S button will start the factory reset.
4. During factory reset, the LED will turn solid green for about 1s, then the blue and red LED will start blinking in Mode 3 for approx. 2s.
5. The blue LED will be blinking in Mode 1 if the Factory reset is successful.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.

Installation

The Device can control various types of loads (e.g., bulbs). Each circuit can support a load up to 10 A (with a total of 16 A for both circuits) and its power consumption is measured individually and in total (AC only). It can be retrofitted into standard electrical wall boxes, behind power sockets and light switches or other places with limited space.
⚠CAUTION! Danger of electrocution. Mounting/installation of the Device to the power grid has to be performed with caution, by a qualified electrician.
⚠WARNING! Danger of electrocution. Every change in the connections has to be done after ensuring there is no voltage present at the Device terminals.
⚠CAUTION! Use the Device only with a power grid and appliances that comply with all applicable regulations. A short circuit in the power grid or any appliance connected to the Device may damage it.
⚠CAUTION! Do not connect the Device to appliances exceeding the given max. load!
⚠CAUTION! Do not shorten the antenna.
⚠RECOMMENDATION: Place the antenna as far away as possible from metal elements, as they can cause signal interference.
⚠CAUTION! Connect the Device only in the way shown in these instructions. Any other method could cause damage and/or injury.
⚠CAUTION! Do not install the Device where it can get wet.
⚠CAUTION! Do not use the Device if it has been damaged!
⚠CAUTION! Do not attempt to service or repair the Device yourself!
⚠RECOMMENDATION: Connect the Device using solid single-core wires with increased insulation heat resistance not less than PVC T105°C (221°F).
⚠CAUTION! Before starting the mounting/installation of the Device, check that the breakers are turned off and there is no voltage on their terminals. This can be done with a phase tester or multimeter. When you are sure that there is no voltage, you can proceed to connecting the wires.

AC-Power
For AC circuits connect both L terminals to the Live wire and the N terminal to the Neutral wire. Connect the first load circuits to the O1 terminal and the Neutral wire. Connect the second load circuits to the O2 terminal and the Neutral wire. Connect the first switch/push-button to the SW1 terminal and the Live wire. Connect the second switch/push-button to the SW2 terminal and the Live wire.

DC-Power
For DC circuits connect both terminals to the GND wire and the + terminal to the Positive wire. Connect the first load circuits to the O1 terminal and the Positive wire. Connect the second load circuits to the O2 terminal and the Positive wire. Connect the first switch/ push-button to the SW1 terminal and the GND wire. Connect the second switch/push-button to the SW2 terminal and the GND wire.


⚠CAUTION! Use only one phase AC circuit. Do not use mixed AC and DC circuits.
⚠RECOMMENDATION: For inductive appliances that cause voltage spikes during switching on/off, such as electrical motors, fans, vacuum cleaners and similar ones, RC snubber (0.1 μF / 100 Ω / 1/2 W / 600 V AC) should be connected parallel to the appliance.
⚠CAUTION! Do not allow children to play with the push-buttons/switches connected to the Device. Keep the devices for remote control of Shelly Qubino (mobile phones, tablets, PCs) away from children.

LEGEND Device terminals:
N: Neutral terminal
L: Live terminal (110–240 V AC)
SW1: Switch/push-button input terminal (controlling O1)
SW2: Switch/push-button input terminal (controlling O2)
• O1: Load circuit output terminal
• O2: Load circuit output terminal
+: 24-30 V DC positive terminals
: 24-30 V DC ground terminals

Wires:
N: Neutral wire
L: Live wire (110-240 V AC)
+: 24–30 V DC positive wire
GND: 24–30 V DC ground wire  

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.

Inclusion

1. Connect the Device to a power supply.
2. Check if the blue LED is blinking in Mode 1. If so, the Device is not added to a Z-Wave™ network.
3. Enable add/remove mode on the gateway.
4. To enter the setting mode, quickly press and hold the S button on the Device until the LED turns Solid blue.
5. Quickly release and then press and hold (> 2 s) the S button on the Device until the blue LED starts blinking in Mode 3. Releasing the S button will start the LEARN MODE.
6. The blue LED will be blinking in Mode 2 during the adding process.
7. The load connected to O will be blinking 1s on/1s off/1s on/1s off if the Device is successfully added to a Z-Wave™ network.
8. The green LED will be blinking in Mode 1 if the Device is successfully added to a Z-Wave™ network.

Exclusion

1. Connect the Device to a power supply.
2. Check if the green LED is blinking in Mode 1. If so, the Device is added to a Z-Wave™ network.
3. Enable add/remove mode on the gateway.
4. To enter the Setting mode, quickly press and hold the S button on the Device until the LED turns Solid blue. 
5. Quickly release and then press and hold (> 2s) the S button on the Device until the blue LED starts blinking in Mode 3. Releasing the S button will start the LEARN MODE.
6. The blue LED will be blinking in Mode 2 during the removing process.
7. The load connected to O will be blinking 1s on/1s off/1s on/1s off if the Device is successfully removed from a Z-Wave™ network.
8. The blue LED will be blinking in Mode 1 if the Device is successfully removed from a Z-Wave™ network.

Product Usage

LED SIGNALIZATION

Supported load types

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association - one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.

Association Groups:

Group Number Maximum Nodes Description
1 9 Lifeline
2 9 Switch 1 - Basic ON/OFF
3 9 Switch 1 - Multilevel
4 9 Switch 2 - Basic ON/OFF
5 9 Switch 2 - Multilevel

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.

IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.

Parameter 1: SW (SW1) Switch type

This parameter defines as what type the device should treat the switch connected to the SW (SW1) terminal.
Size: 1 Byte, Default Value: 2

Setting Description
0 momentary switch
1 toggle switch (contact closed - ON / contact opened - OFF)
2 toggle switch (device changes status when switch changes status)

Parameter 1: SW (SW2) Switch type

This parameter defines as what type the device should treat the switch connected to the SW (SW2) terminal.
Size: 1 Byte, Default Value: 2

Setting Description
0 momentary switch
1 toggle switch (contact closed - ON / contact opened - OFF)
2 toggle switch (device changes status when switch changes status)

Parameter 6: Inputs SW1 & SW2 Swap

This parameter allows to swap the operation of switches connected to inputs SW1 and SW2 without changing the wiring.
Size: 1 Byte, Default Value: 0

Setting Description
0 default (SW1 - O1, SW2 - O2)
1 swapped (SW1 - O2, SW2 - O1)

Parameter 16: Outputs O1 & O2 swap

This parameter allows to swap the operation of outputs O1 and O2 without changing the wiring.
Size: 1 Byte, Default Value: 0

Setting Description
0 default
1 reversed

Parameter 17: Restore state of O (O1) after power failure

This parameter determines if on/off status is saved and restored for load connected to O (O1) after power failure.
Size: 1 Byte, Default Value: 0

Setting Description
0 Device saves last on/off status and restores it after a power failure
1 Device does not save on/off status and does not restore it after a power failure, it remains off

Parameter 18: Restore state of O (O2) after power failure

This parameter determines if on/off status is saved and restored for load connected to O (O2) after power failure.
Size: 1 Byte, Default Value: 0

Setting Description
0 Device saves last on/off status and restores it after a power failure
1 Device does not save on/off status and does not restore it after a power failure, it remains off

Parameter 19: O (O1) Auto OFF with timer

If Load O (O1) is ON, you can schedule it to turn OFF automatically after a period of time defined in this parameter. The timer is reset to zero each time the device receives an ON command, either remotely (from the Gateway or associated device) or locally from the switch.
Size: 2 Byte, Default Value: 0

Setting Description
0 Auto OFF Disabled
1 - 32535 1 - 32535 seconds (or milliseconds – see Parameter no. 25. Auto OFF timer enabled for a given amount of seconds (or milliseconds) resolution 100ms

Parameter 20: O (O1) Auto ON with timer

If Load O (O1) is OFF, you can schedule it to turn ON automatically after a period of time defined in this parameter. The timer is reset to zero each time the device receives an OFF command, either remotely (from the Gateway or associated device) or locally from the switch.
Size: 2 Byte, Default Value: 0

Setting Description
0 Auto ON Disabled
1 - 32535 1 - 32535 seconds (or milliseconds – see Parameter no. 25. Auto ON timer enabled for a given amount of seconds (or milliseconds) resolution 100ms

Parameter 21: O (O2) Auto OFF with timer

If Load O (O2) is ON, you can schedule it to turn OFF automatically after a period of time defined in this parameter. The timer is reset to zero each time the device receives an ON command, either remotely (from the Gateway or associated device) or locally from the switch.
Size: 2 Byte, Default Value: 0

Setting Description
0 Auto OFF Disabled
1 - 32535 1 - 32535 seconds (or milliseconds – see Parameter no. 26. Auto OFF timer enabled for a given amount of seconds (or milliseconds) resolution 100ms

Parameter 22: O (O2) Auto ON with timer

If Load O (O2) is OFF, you can schedule it to turn ON automatically after a period of time defined in this parameter. The timer is reset to zero each time the device receives an OFF command, either remotely (from the Gateway or associated device) or locally from the switch.
Size: 2 Byte, Default Value: 0

Setting Description
0 Auto ON Disabled
1 - 32535 1 - 32535 seconds (or milliseconds – see Parameter no. 26. Auto ON timer enabled for a given amount of seconds (or milliseconds) resolution 100ms

Parameter 23: O (O1) contact type - NO/NC

Set value determines the type of Relay contact type for O (O1) output. The Relay contact type can be normally open (NO) or normally closed (NC).
Size: 1 Byte, Default Value: 0

Setting Description
0 NO
1 NC

Parameter 24: O (O2) contact type - NO/NC

Set value determines the type of Relay contact type for O (O2) output. The Relay contact type can be normally open (NO) or normally closed (NC).
Size: 1 Byte, Default Value: 0

Setting Description
0 NO
1 NC

Parameter 25: Set timer units to s or ms for O (O1)

Set Timer Units to Seconds or Milliseconds Choose if you want to set the timer in seconds or milliseconds in Parameters No. 19, 20.
Size: 1 Byte, Default Value: 0

Setting Description
0 timer set in seconds
1 timer set in milliseconds

Parameter 26: Set timer units to s or ms for O (O2)

Set Timer Units to Seconds or Milliseconds Choose if you want to set the timer in seconds or milliseconds in Parameters No. 21, 22.
Size: 1 Byte, Default Value: 0

Setting Description
0 timer set in seconds
1 timer set in milliseconds

Parameter 36: O (O1) Power report on change - percentage

This parameter determines the minimum change in consumed power that will result in sending new report to the main controller.
Size: 1 Byte, Default Value: 50

Setting Description
0 reports are disabled
1 - 100 % change in power

Parameter 37: O (O2) Power report on change - percentage

This parameter determines the minimum change in consumed power that will result in sending new report to the main controller.
Size: 1 Byte, Default Value: 50

Setting Description
0 reports are disabled
1 - 100 % change in power

Parameter 39: Minimal time between reports (O) O1

This parameter determines minimum time that has to elapse before sending new power report on O (O1) to the main controller.
Size: 1 Byte, Default Value: 30

Setting Description
0 reports are disabled
1 - 120 report interval in s

Parameter 40: Minimal time between reports (O) O2

This parameter determines minimum time that has to elapse before sending new power report on O (O2) to the main controller.
Size: 1 Byte, Default Value: 30

Setting Description
0 reports are disabled
1 - 120 report interval in s

Parameter 91: Water Alarm

This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification.
Size: 4 Byte, Default Value: 0

Setting Description
0 no action
1 open relay
2 close relay

Parameter 92: Smoke Alarm

This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification.
Size: 4 Byte, Default Value: 0

Setting Description
0 no action
1 open relay
2 close relay

Parameter 93: CO Alarm

This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification.
Size: 4 Byte, Default Value: 0

Setting Description
0 no action
1 open relay
2 close relay

Parameter 94: Heat Alarm

This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification.
Size: 4 Byte, Default Value: 0

Setting Description
0 no action
1 open relay
2 close relay

Parameter 120: Factory Reset

Reset to factory default settings and removed from the z-wave network
Size: 4 Byte, Default Value: 0

Setting Description
0 Don’t do Factory reset
1431655765 Do the Factory reset (hex 0x55555555)

Technical Data

Dimensions 42 x 37 x 16 mm
Weight 28 gr
Hardware Platform EFR32ZG23
EAN 3800235269015
Device Type On/Off Power Switch
Generic Device Class Binary Switch
Firmware Version 10.27
Z-Wave Version 07.13
Z-Wave Product Id 0x0460.0x0002.0x0081
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW

Supported Command Classes

  • Ss Basic
  • Switch Binary
  • Meter
  • Transport Service
  • Association Grp Info
  • Device Reset Locally
  • Zwaveplus Info
  • Multi Channel
  • Supervision
  • Configuration
  • Alarm
  • Manufacturer Specific
  • Powerlevel
  • Firmware Update Md
  • Association
  • Version
  • Indicator
  • Multi Channel Association
  • Security
  • Security 2

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways,Remote Controls or battery operated wall controllers.
  • Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators and even remote controls.
  • Primary Controller — is the central organizer of the network. It must be a controller. There can be only one primary controller in a Z-Wave network.
  • Inclusion — is the process of adding new Z-Wave devices into a network.
  • Exclusion — is the process of removing Z-Wave devices from the network.
  • Association — is a control relationship between a controlling device and a controlled device.
  • Wakeup Notification — is a special wireless message issued by a Z-Wave device to announces that is able to communicate.
  • Node Information Frame — is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.