This is a
Press and hold the SOS push button until the indicator light starts blinking. Then release the button to start the inclusion process.
(Note: Normally button should be pressed for 2 seconds but in case the product is already included it can take up to 12 seconds before the indicator light will start blinking.)
The Panic Watch is similar to the Panic Button, except for that this watch can be worn as a wristband. The Panic Watch is used within the Safety Services. With the Panic Watch you are able to send a message automatically to a preconfigured e-mail address. Actions from the Panic Watch can be programmed freely. The Panic Watch will operate on a single built-in battery. The expected lifetime is four years and a low battery signal will be send automatically.
Reset to factory default | Set Parameter 1 to value 255 |
Inclusion | Press and hold the SOS push button until the indicator light starts blinking. Then release the button to start the inclusion process. (Note: Normally button should be pressed for 2 seconds but in case the product is already included it can take up to 12 seconds before the indicator light will start blinking.) |
Exclusion | Press and hold the SOS push button until the indicator light starts blinking. Then release the button to start the exclusion process. (Note: Normally button should be pressed for 2 seconds but in case the product is already included it can take up to 12 seconds before the indicator light will start blinking.) |
NIF | XXXNIF |
Wakeup | Press and hold the Panic Watch for 14 seconds. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 8 | If configuration parameter 4 configured with value 0 then this group is used - SOS button: send ALARM_REPORT. If configuration parameter 4 configured with value other then 0 (1-255) then this group is used - SOS button: send BASIC_SET, 0xFF. |
2 | 8 | Not used on application. |
Set all configuration values to default values (factory settings). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | disable |
255 | set to default |
The time that the panic pushbutton must be pressed before a (panic) message is sent out to the controller. Size: 1 Byte, Default Value: 1000
Setting | Description |
---|---|
0 | Send directly the panic message when pressed |
1 - 255 | Send a panic message after you keep holding the button pressed for this value x 10ms. |
Minimum time that led feedback is shown after a panic message. Size: 1 Byte, Default Value: 100
Setting | Description |
---|---|
0 | Led only stays on during the ‘send time’. |
1 - 233 | Led stays on during send time + this value*10ms. |
With this config parameter you can map the buttons to send different Z-Wave messages. Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 | SOS button sends an ALARM_REPORT to nodes group 1 |
1 - 255 | SOS button sends an BASIC_SET, 0xFF to nodes group 1 |
Dimensions | 46 x 46 x 15 mm |
Weight | 33.6 gr |
EAN | 0632181493748 |
IP Class | IP 21 |
Voltage | 3V |
Battery Type | 1 * CR2450 3.0V |
Device Type | Panic Button |
Generic Device Class | Binary Sensor |
Firmware Version | 00.20 |
Z-Wave Version | 03.2a |
Z-Wave Product Id | 0x008a.0x0015.0x0101 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |