Quickstart
This is a
secure
Z-Wave Device for XXXQFrequencyName.
To run this device please insert fresh 2 * AA batteries.
To run this device please make sure the internal battery is fully charged.
To add this device to your network execute the following action:
1. Insert the Batteries
2. If “PA” is not displayed, press both buttons, until “PA” apppears.
3. Counter counts down from 99.
4. Inclusion successful. Received Node ID is displayed.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Product Description
Comet Z-Wave is a Z-Wave radio standard compatible energy-saving radiator thermostat.
Installation
Batteries
1. Remove the battery cover
2. Now insert the batteries. Pay attention to the correct polarity! Do not use rechargeable batteries!
3. Reattach the battery cover to the Comet Z-Wave by pressing it on until it clicks.
In case of a later battery change, the configuration of your Comet Z-Wave will be preserved.
Mounting
After adding (inclusion), the LED display shows an animation and the thermostat moves to the mounting position. Subsequently, the LED display shows “Ad”.
Follow the mounting steps below:
1. Unscrew old thermostatic head completely, loosen fastening and pull it off the valve.
2. If necessary, select a suitable adapter and mount it on the valve.
3. Screw the thermostat onto the valve or adapter by turning the union nut clockwise.
Adaptation1. When "Ad" is shown in the display, press and hold up and down key together for 3 seconds, to start adaptation.
2. When the operation is finished, the temperature 21° is displayed.
NOTE:
If a new adaptation is required later, remove the batteries from the device and reinsert the batteries.
Ad” then appears on the LED display. Now start the adaptation by simultaneously holding down both keys for 3 seconds.
Dismounting
Remove the Comet Z-Wave from the network before disassembling the device. To do this, please put your Z-Wave controller in the removal mode (Exclusion).
Then press and hold the button in the battery compartment for 5 seconds
The LED display shows Node ID 0 if the removal was successful and the valve tappet moves into mounting position.
Wait until the display shows “PA”. Now unscrew the union nut counterclockwise and remove it from the Comet Z-Wave valve.

Product Usage
Buttons

Display

Setting the target Temperature
- The set temperature is changed via the up and down button.
- The local change of the setpoint temperature puts the Comet Z-Wave in heating mode.
- The setpoint temperature of the setback mode can only be adjusted by radio.
- The input range of the set temperature is 8°- 28°C.
- If the temperature is increased or decreased beyond this, the Comet Z-Wave will switch to boost or off mode.
Child protect / Key lock
- The child lock can be switched on and also switched off again by simultaneously holding down the up and down button for 3 seconds, when the display is off.
- If the Comet Z-Wave is set to the highest protection level by radio, local operation is no longer possible. The child safety lock can then also no longer be removed locally.
Changing Operation Mode
OFF-Mode
Press the key down as long as “--” is displayed on your thermostat.
Heating-Mode
If the device is not in the heating-mode, change the temperature by using keys, between 8 to 28 degrees.
Boost-Mode
If your device is not in the Boost-mode, keep the up key pressed, until the device displays “ON”
Window open detection
- If the temperature drops abruptly, the window open mode is activated. The Comet Z-Wave will switch to off mode for 10 minutes. The window-open mode is automatically exited after 10 minutes and the previously active mode is restored.
- In Manufacturer Specific Mode, the window-open detection is not executed.
- The sensitivity of the window open detection can be configured.
Troubleshooting
Reset to factory default |
Press and hold the button in the battery compartment of your Comet Z-Wave for at least 10 seconds. From the 5th second on, a counter will run on the thermostat’s display. Keep the button pressed until the 10 appears on your Comet Z-Wave. Then “PA” will be shown again on the display and the controller will be in teach-in mode |
Inclusion |
1. Insert the Batteries 2. If “PA” is not displayed, press both buttons, until “PA” apppears. 3. Counter counts down from 99. 4. Inclusion successful. Received Node ID is displayed. |
Exclusion |
1. Open battery compartment 2. Press key in battery compartment for 5 seconds. 3. Radio symbol flashes during exclusion mode "LE". 4. Countdown starts from 99 to 0 5. If you see "0", exclusion is successful |
NIF |
XXXNIF |
Wakeup |
XXXWakeupDescription |
Protection |
XXXProtection |
FirmwareUpdate |
XXXFirmwareUpdate |
SetAssociation |
XXXSetAssociation |
Association Groups:
Group Number |
Maximum Nodes |
Description |
1 |
1 |
Lifeline |
Configuration Parameters
Parameter 1: LCD invert
Size: 1 Byte, Default Value: 0
Setting |
Description |
0 |
normal |
1 |
mirrored |
Parameter 2: LCD Timeout
Size: 1 Byte, Default Value: 5
Setting |
Description |
5 - 30 |
Timeout in seconds |
Parameter 4: Battery status
Size: 1 Byte, Default Value: 0
Setting |
Description |
0 |
Only by battery event |
1 |
Daily |
Parameter 5: Actual-Temperature
Size: 1 Byte, Default Value: 5
Setting |
Description |
0 |
disabled |
1 - 50 |
0.1°C - 5.0°C |
Parameter 7: Window-open detection
Size: 1 Byte, Default Value: 1
Setting |
Description |
0 |
Deactivated |
1 |
low sensitivity |
2 |
medium sensitivity |
3 |
high sensitivity |
Parameter 8: Actual-Temperature- Offset
Size: 1 Byte, Default Value: 0
Setting |
Description |
-50 - 50 |
-5,0°C - (+) 5,0°C |
Technical Data
Dimensions |
0.0620000x0.0670000x0.0800000 mm |
Weight |
111 gr |
Hardware Platform |
ZG310 |
EAN |
4260012712421 |
IP Class |
IP IP20 |
Battery Type |
2 * AA |
Firmware Version |
0b.1a |
Z-Wave Version |
07.0f |
Z-Wave Product Id |
0x0148.0x0004.0x0003 |
Frequency |
Europe - 868,4 Mhz |
Maximum transmission power |
5 mW |