NOTE: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply , connect the sensor and re-include the module.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Flush 2 relays module is used for switching on or off two electrical devices (e.g. lights, fans, etc ...). The module can be controlled either through Z-Wave network or through the wall switches.
The module is designed to be mounted inside a “flush mounting box”, hidden behind a traditional wall switch.
Module measures power consumption of two electrical devices and supports connection of digital temperature sensor. It is designed to act as repeater in order to improve range and stability of Z-wave network.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
If the service button S is pressed for mor ethan 6 seconds the module will be reset to the factory defoult state
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Lifeline group (reserved for communication with the main controller). |
2 | 16 | basic on/off (triggered at change of the output Q1 state and reflecting its state) |
3 | 16 | switch binary report (triggered at change of the output Q1 state and reflecting its state) |
4 | 16 | power meter report (triggered at change of the output Q1 state) |
5 | 16 | basic on/off (triggered at change of the output Q2 state and reflecting its state) |
6 | 16 | switch binary report (triggered at change of the output Q2 state and reflecting its state) |
7 | 16 | power meter report (triggered at change of the output Q2 state) |
8 | 16 | multilevel sensor report (triggered at change of temperature sensor) |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Input 1 switch type Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | mono-stable switch type (push button) |
1 | bi-stable switch type |
Input 2 switch type Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | mono-stable switch type (push button) |
1 | bi-stable switch type |
Activate / deactivate functions ALL ON/ALL OFFFlush 2 relays module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
0 | ALL ON is not active ALL OFF is not active |
1 | ALL ON is not active ALL OFF active |
2 | ALL ON active ALL OFF is not active |
255 | ALL ON active, ALL OFF active |
When relay Q1 is ON it goes automatically OFF after time defined by this parameter. Timer is reset to zero each time the module receive ON command regardless from where it comes (push button, associated module, controller,..). Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Auto OFF disabled |
1 - 32535 | 1second (0,01s) - 32535 seconds (325,35s) Auto OFF enabled with define time, step is 1s or 10ms according to parameter nr.15 |
When relay Q1 is OFF it goes automatically ON after time defined by this parameter. Timer is reset to zero each time the module receive OFF command regardless from where it comes (push button, associated module, controller,..). Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Auto ON disabled |
1 - 32535 | 1second (0,01s) - 32536 seconds (325,35s) Auto ON enabled with define time, step is 1s or 10ms according to parameter nr.15 |
When relay Q2 is ON it goes automatically OFF after time defined by this parameter. Timer is reset to zero each time the module receive ON command regardless from where it comes (push button, associated module, controller,..). Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Auto OFF disabled |
1 - 32535 | 1second (0,01s) - 32535 seconds (325,35s) Auto OFF enabled with define time, step is 1s or 10ms according to parameter nr.15 |
When relay Q2 is OFF it goes automatically ON after time defined by this parameter. Timer is reset to zero each time the module receive OFF command regardless from where it comes (push button, associated module, controller,..). Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Auto ON disabled |
1 - 32535 | 1second (0,01s) - 32536 seconds (325,35s) Auto ON enabled with define time, step is 1s or 10ms according to parameter nr.15 |
Automatic turning off / on seconds or milliseconds selectionNote that parameter is valid for both outputs Q1, Q2 and is the same for turning off or on. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | seconds selected |
1 | milliseconds selected |
Saving the state of the relays Q1 and Q2 after a power failure Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Flush 2 relays module saves its state before power failure (it returns to the last position saved before a power failure) |
1 | Flush 2 relays module does not save the state after a power failure, it returns to "off" position. |
Set value means percentage, set value from 0 - 100 = 0% - 100%. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 | Reporting Disabled |
1 - 100 | 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%. NOTE: if power changed is less than 1W, the report is not send (pushed), independent of percentage set. |
Set value means percentage, set value from 0 - 100 = 0% - 100% Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 | Reporting Disabled |
1 - 100 | 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%. NOTE: if power changed is less than 1W, the report is not send (pushed), independent of percentage set. |
Set value means time interval (0 - 32535) in seconds, when power report is send. Size: 2 Byte, Default Value: 300
Setting | Description |
---|---|
0 | Reporting Disabled |
1 - 32535 | = 1 second - 32535 seconds. Reporting enabled, Power report is send with time interval set by entered value. |
Set value means time interval (0 - 32535) in seconds, when power report is send. Size: 2 Byte, Default Value: 300
Setting | Description |
---|---|
0 | Reporting Disabled |
1 - 32535 | = 1 second - 32535 seconds. Reporting enabled, Power report is send with time interval set by entered value. |
Set value means the type of the device that is connected to the Q1 output. The device type can be normally open (NO) or normally close (NC). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | When system is turned off the output is 0V (NC). |
1 | When system is turned off the output is 230V (NO). |
Set value means the type of the device that is connected to the Q2 output. The device type can be normally open (NO) or normally close (NC). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | When system is turned off the output is 0V (NC). |
1 | When system is turned off the output is 230V (NO). |
Set value is added or subtracted to actual measured value by sensor. Size: 2 Byte, Default Value: 32536
Setting | Description |
---|---|
1 - 100 | value from 0.1 deg.C to 10.0 deg.C is added to actual measured temperature. |
1001 - 1100 | value from -0.1 deg.C to -10.0 deg.C is subtracted to actual measured temperature. |
32536 | offset is 0.0 deg.C |
If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 | Reporting disabled |
1 - 127 | 0,1 deg.C - 12.7 deg.C. - step is 0,1 deg.C |
Dimensions | 42x37x16 mm |
Weight | 28 gr |
Hardware Platform | ZM5202 |
EAN | 3830062070119 |
IP Class | IP 20 |
Voltage | 230 V |
Load | 2x 4A |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-15100010 |
Z-Wave Product Id | 0x0159.0x0002.0x0051 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |